1SDX255127R1 ABB EPX-XT4S-TM0634 63A 4-Pole 50kA TMA Moulded Case Circuit Breaker

1SDX255127R1 ABB EPX-XT4S-TM0634 63A 4-Pole 50kA TMA Moulded Case Circuit Breaker

ABB EPX-XT4S-TM0634 is a 63 A four-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution.

SKU: 1SDX255127R1Alt SKU: EPX-XT4S-TM0634MPN: 1SDX255127R1
Price
List Price £923.35 ex VAT
Your Price (ex VAT)
£923.35
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £923.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£923.35

Why Choose the ABB EPX-XT4S-TM0634 63A 4-Pole 50kA MCCB?

The ABB EPX-XT4S-TM0634 is a 63 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit, this circuit breaker is suitable for commercial, industrial and infrastructure electrical installations requiring reliable circuit protection.

Part of the ABB Protecta Power Devices range, the EPX-XT4S-TM0634 belongs to the ABB SACE Tmax XT4S circuit breaker family. Its thermal-magnetic protection release combines thermal overload protection with magnetic short-circuit protection, helping safeguard electrical conductors, connected equipment and distribution circuits against abnormal current conditions.

With its 63 A rated current, four-pole configuration and 50 kA breaking capacity, the EPX-XT4S-TM0634 provides a practical solution for three-phase electrical distribution systems requiring four-pole switching. Its combination of established ABB circuit breaker technology and adjustable thermal-magnetic protection makes it suitable for electrical contractors, panel builders and maintenance engineers working with compatible ABB Protecta Power distribution assemblies.

Key Advantages

  • 63 A rated current: Suitable for appropriately designed commercial and industrial distribution circuits.
  • 50 kA breaking capacity: Provides substantial short-circuit interruption capability.
  • Four-pole configuration: Supports three-phase distribution systems requiring a fourth switching pole.
  • TMA thermal-magnetic protection: Combines overload and short-circuit protection functions.
  • Thermal overload protection: Helps protect conductors and equipment against sustained excessive current.
  • Magnetic short-circuit protection: Provides rapid protective operation during sufficiently high fault currents.
  • Adjustable protection functionality: Supports configuration of protection characteristics for suitable electrical applications.
  • ABB SACE Tmax XT4S technology: Provides dependable switching and protective performance.
  • High breaking capacity: Suitable for distribution circuits with demanding prospective fault-current requirements.
  • Manual switching and automatic tripping: Combines circuit control with automatic fault protection.
  • Protecta Power compatibility: Designed for use within appropriately configured ABB distribution equipment.

Key Features

  • ABB EPX-XT4S-TM0634 moulded case circuit breaker.
  • 63 A rated current.
  • Four-pole (4P) configuration.
  • 50 kA short-circuit breaking capacity.
  • ABB SACE Tmax XT4S circuit breaker platform.
  • TMA adjustable thermal-magnetic trip unit.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit faults.
  • Automatic protective tripping during applicable overcurrent conditions.
  • Manual operating mechanism for circuit switching.
  • Four-pole switching arrangement for suitable three-phase electrical systems.
  • S breaking capacity class within the ABB Tmax XT4 family.
  • Designed for low-voltage AC electrical distribution.
  • Suitable for compatible ABB Protecta Power distribution assemblies.
  • Applicable to commercial and industrial switchgear installations.

Adjustable Thermal-Magnetic Protection for Four-Pole Distribution

The ABB EPX-XT4S-TM0634 uses a TMA thermal-magnetic protection release to respond to overload and short-circuit conditions. The thermal protection element responds to sustained excessive current through a time-dependent operating characteristic, helping protect conductors and connected equipment against overheating. The magnetic protection element provides rapid tripping when the current reaches the applicable short-circuit threshold. The available adjustment ranges and final protection settings should be confirmed against ABB's technical documentation for the supplied release.

The ABB SACE Tmax XT4S platform combines robust circuit breaker construction with dependable low-voltage protection. Featuring a 63 A rated current, four-pole construction and 50 kA breaking capacity, the EPX-XT4S-TM0634 is suitable for distribution circuits requiring four-pole switching and substantial short-circuit interruption capability. Correct selection must consider the operating voltage, prospective fault current, conductor ratings, neutral switching requirements and protective coordination.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase distribution systems requiring four-pole switching.
  • 63 A outgoing feeders and distribution circuits.
  • Sub-distribution panels in commercial buildings.
  • Industrial control panel supply circuits.
  • Manufacturing and production facilities.
  • Warehouses and logistics installations.
  • Commercial building electrical infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Distribution circuits requiring thermal overload and magnetic short-circuit protection.
  • Electrical maintenance, refurbishment and distribution system upgrades.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4S
ABB order code 1SDX255127R1
Product type Moulded case circuit breaker (MCCB)
Rated current 63 A
Number of poles 4
Short-circuit breaking capacity 50 kA
Trip unit designation TMA
Protection technology Adjustable thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Frame family XT4
Breaking capacity class S
Operating mechanism Manual switching with automatic protective tripping
Application Low-voltage three-phase electrical distribution
Applicable circuit breaker standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0634 used for?

The ABB EPX-XT4S-TM0634 is a 63 A four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits.

What is the rated current of the EPX-XT4S-TM0634?

The EPX-XT4S-TM0634 has a rated current of 63 A. Circuit selection must account for the connected load, conductor ratings and installation conditions.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4S-TM0634 has a specified 50 kA short-circuit breaking capacity. The applicable rating at the installation voltage must be checked against the prospective fault current.

What does TMA mean on the ABB EPX-XT4S-TM0634?

TMA identifies an adjustable thermal-magnetic trip unit. Thermal protection responds to sustained overload currents, while magnetic protection provides rapid operation during short-circuit faults.

Does the ABB EPX-XT4S-TM0634 have adjustable protection settings?

Yes. The TMA designation identifies adjustable thermal-magnetic protection functionality. The available adjustment ranges should be confirmed against ABB's documentation for the supplied device.

Is the EPX-XT4S-TM0634 a four-pole circuit breaker?

Yes. The EPX-XT4S-TM0634 has a four-pole (4P) configuration suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching.

What ABB circuit breaker series does this model belong to?

The EPX-XT4S-TM0634 belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT4S circuit breaker platform.

What is the difference between a three-pole and four-pole MCCB?

A three-pole MCCB switches three phase conductors, while a four-pole MCCB provides an additional switching pole, commonly used for the neutral conductor. The appropriate configuration depends on the electrical installation and earthing arrangement.

Can the EPX-XT4S-TM0634 be installed in industrial distribution panels?

Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its electrical ratings, protection characteristics and installation requirements match the application.

What is the ABB order code for the EPX-XT4S-TM0634?

The ABB order code is 1SDX255127R1, identifying the EPX-XT4S-TM0634 within the ABB Protecta Power Devices range.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, electrical contractors and industrial maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT4S-TM0634 combines a 63 A rated current, four-pole configuration and 50 kA breaking capacity with TMA thermal-magnetic protection, making it a practical solution for commercial and industrial electrical distribution.