ABB EPX-XT4S-TM0404 is a 40 A four-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX255125R1Alt SKU: EPX-XT4S-TM0404MPN: 1SDX255125R1
Price
List Price £923.35 ex VAT
Your Price (ex VAT)
£923.35
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £923.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£923.35

Why Choose the ABB EPX-XT4S-TM0404 40A 4-Pole 50kA MCCB?

The ABB EPX-XT4S-TM0404 is a high-performance 40 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT4S160 platform, delivering reliable electrical protection for commercial buildings, industrial facilities and electrical infrastructure.

Equipped with an ABB TMA thermal-magnetic trip unit, the EPX-XT4S-TM0404 combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption during short-circuit faults. These complementary protection functions help safeguard electrical cables, switchgear and connected equipment while allowing protection settings to be configured according to the requirements of the installation.

With a 40 A rated current, four-pole construction and 50 kA short-circuit breaking capacity, this MCCB is suitable for three-phase electrical distribution systems requiring four-pole switching and substantial fault-interruption capability. Its ABB Tmax XT4S160 frame, fixed-mounted construction and front terminal connections support integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • 40 A rated current for commercial and industrial electrical distribution circuits.
  • Four-pole configuration supports switching of four conductors in suitable three-phase electrical systems.
  • 50 kA short-circuit breaking capacity provides substantial fault-interruption capability.
  • ABB TMA thermal-magnetic trip unit combines adjustable overload and short-circuit protection.
  • Adjustable thermal protection helps safeguard electrical cables against sustained excessive current.
  • Thermal adjustment range of 28–40 A provides flexibility when configuring overload protection.
  • Adjustable magnetic protection enables the instantaneous short-circuit trip threshold to be configured.
  • Magnetic adjustment range of 200–400 A supports short-circuit protection coordination.
  • ABB SACE Tmax XT4S160 platform offers robust construction for demanding electrical distribution applications.
  • Four-pole switching arrangement supports suitable three-phase and neutral distribution systems.
  • 140 mm four-pole frame width supports efficient installation planning within compatible switchboards.
  • Fixed-mounted construction provides a practical arrangement for electrical distribution assemblies.
  • Designed for integration into compatible ABB Protecta Power distribution systems.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT4S160 moulded case circuit breaker platform.
  • 40 A rated current.
  • Four-pole (4P) construction.
  • 50 kA short-circuit breaking capacity.
  • TMA thermal-magnetic trip unit.
  • Adjustable thermal overload protection from 28–40 A.
  • Adjustable magnetic short-circuit protection from 200–400 A.
  • Thermal adjustment range: 0.7–1 × In.
  • Magnetic adjustment range: 5–10 × In.
  • XT4S160 frame with a maximum frame rating of 160 A.
  • 140 mm four-pole frame width.
  • Fixed-mounted construction for compatible distribution assemblies.
  • Front terminal connections for electrical conductor termination.
  • Manual toggle operating mechanism with trip indication and reset capability.
  • Four-pole switching for suitable three-phase electrical distribution systems.
  • Compatible with appropriately selected ABB Tmax XT4 installation accessories.

Adjustable Four-Pole Thermal-Magnetic Protection for Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT4S-TM0404 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Its TMA thermal-magnetic trip unit incorporates adjustable thermal protection against sustained overcurrent and an adjustable magnetic element for rapid short-circuit fault interruption. The thermal setting range of 28–40 A and magnetic setting range of 200–400 A allow protection characteristics to be configured according to conductor requirements, connected loads and coordination with other protective devices.

The ABB SACE Tmax XT4 circuit breaker family is engineered for dependable protection in modern low-voltage electrical distribution assemblies. The EPX-XT4S-TM0404 is particularly suitable for installations requiring 40 A four-pole circuit protection and a 50 kA short-circuit breaking rating. Its four-pole construction supports applications where four-conductor switching is required, subject to the installation's earthing arrangement and neutral protection requirements. Circuit breaker selection should account for operating voltage, prospective fault current, conductor characteristics, load requirements and protective device coordination. Where the MCCB supplies a motor circuit, dedicated motor overload protection may also be necessary depending on the installation design.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase electrical distribution systems requiring four-pole switching.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuits and electrical feeders.
  • Manufacturing facilities and industrial workshops.
  • Building services electrical distribution systems.
  • Commercial premises, warehouses and logistics centres.
  • Industrial control panels requiring adjustable thermal-magnetic protection.
  • Electrical distribution circuits requiring high short-circuit breaking capacity.
  • Three-phase and neutral distribution arrangements requiring coordinated four-pole switching.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT4S160
ABB order code 1SDX255125R1
Corresponding ABB circuit breaker reference 1SDA068317R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 40 A
Number of poles 4
Short-circuit breaking capacity 50 kA
Trip unit TMA
Trip unit technology Thermal-magnetic
Thermal overload protection setting 28–40 A
Thermal adjustment 0.7–1 × In
Magnetic short-circuit protection setting 200–400 A
Magnetic adjustment 5–10 × In
Protection functions Adjustable thermal overload and magnetic short-circuit protection
Frame family XT4S160
Maximum frame rating 160 A
Rated operational voltage Up to 690 V AC
Four-pole frame width 140 mm
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual toggle operation
Switching configuration Four-pole
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0404 used for?

The ABB EPX-XT4S-TM0404 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial electrical installations requiring four-pole switching.

What is the rated current of the EPX-XT4S-TM0404?

The circuit breaker has a 40 A rated current and uses the ABB Tmax XT4S160 frame, which has a maximum frame rating of 160 A. Its adjustable thermal overload protection setting ranges from 28–40 A.

What is the breaking capacity of the ABB EPX-XT4S-TM0404?

The EPX-XT4S-TM0404 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation's operating voltage must be checked against ABB technical documentation and the prospective short-circuit current before selection.

What protection does the TMA thermal-magnetic trip unit provide?

The ABB TMA thermal-magnetic trip unit provides adjustable thermal overload protection and adjustable magnetic short-circuit protection. For this 40 A configuration, the thermal adjustment range is 28–40 A, while the magnetic adjustment range is 200–400 A.

What is the advantage of the four-pole design of the ABB EPX-XT4S-TM0404?

The four-pole (4P) construction allows four conductors to be switched together, making the MCCB suitable for three-phase distribution arrangements where neutral switching is required. The neutral pole's protection characteristics and compatibility with the installation's earthing system must be confirmed during circuit design.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT4S-TM0404 combines a 40 A rating, four-pole construction, 50 kA breaking capacity and adjustable TMA thermal-magnetic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.