ABB EPX-XT2S-TM1254 is a 125 A four-pole moulded case circuit breaker with 50 kA breaking capacity and thermal-magnetic overload and short-circuit protection, designed for commercial and industrial low-voltage electrical distribution systems.
£847.64
The ABB EPX-XT2S-TM1254 is a high-performance 125 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and thermal-magnetic (TMA) protection, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on the established ABB SACE Tmax XT2S circuit breaker platform.
Engineered for dependable low-voltage electrical protection, the EPX-XT2S-TM1254 combines thermal overload protection with magnetic short-circuit protection to help safeguard electrical cables, distribution circuits and connected equipment. Its four-pole construction supports simultaneous switching of three phase conductors and a neutral conductor, making it particularly suitable for three-phase electrical distribution systems requiring four-pole switching and isolation.
With a 125 A rated current, four-pole (4P) configuration and 50 kA breaking capacity, the ABB EPX-XT2S-TM1254 provides an effective solution for electrical distribution boards, industrial power systems and commercial building installations. Its compact design supports efficient integration into compatible ABB Protecta Power assemblies. The product is identified by ABB order code 1SDX255116R1.
Moulded case circuit breakers such as the ABB EPX-XT2S-TM1254 protect low-voltage electrical installations by automatically interrupting current when an overload or short-circuit fault occurs. By combining circuit switching with protective tripping functions, an MCCB helps reduce the risk of damage to electrical cables, distribution equipment and connected electrical loads.
The thermal-magnetic (TMA) protection system uses two complementary operating principles. The thermal element responds to sustained overcurrent conditions that may cause excessive heating, while the magnetic element provides rapid operation when a significant short-circuit fault occurs. Together, these mechanisms provide dependable protection against common electrical fault conditions and help maintain the integrity of electrical distribution systems.
The four-pole configuration makes the EPX-XT2S-TM1254 particularly useful in three-phase electrical distribution systems requiring switching of the neutral conductor alongside the three phase conductors. This arrangement supports four-pole isolation requirements in appropriately designed installations. The specific neutral pole protection characteristics should be verified against the selected circuit breaker configuration and installation requirements.
As part of the ABB Protecta Power Devices range, this MCCB is designed for integration into compatible electrical distribution equipment. The XT2S160 platform provides robust circuit breaker construction, while the 125 A current rating and 50 kA breaking capacity make the device suitable for appropriately rated circuits requiring substantial short-circuit protection capability.
The ABB SACE Tmax XT2S platform is designed for professional electrical distribution applications where reliability, maintainability and efficient panel integration are essential. Correct circuit breaker selection should account for electrical system voltage, prospective short-circuit current, cable ratings, load characteristics and coordination with upstream and downstream protective devices. The stated breaking capacity must be assessed against the applicable operating voltage and installation conditions.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT2S |
| Circuit breaker platform | XT2S160 |
| ABB order code | 1SDX255116R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 125 A |
| Number of poles | 4 |
| Pole configuration | Four-pole (3-phase + neutral) |
| Short-circuit breaking capacity | 50 kA |
| Trip unit type | Thermal-magnetic (TMA) |
| Overload protection | Thermal trip mechanism |
| Short-circuit protection | Magnetic trip mechanism |
| Frame family | XT2S160 |
| Frame current class | 160 A |
| Rated insulation voltage (Ui), XT2S platform | 1,000 V |
| Rated impulse withstand voltage (Uimp), XT2S platform | 8 kV |
| Rated operational voltage, XT2S platform | Up to 690 V AC |
| Switching operation | Manual switching with automatic protective tripping |
| Electrical system | Low-voltage AC distribution |
| Application | Commercial and industrial electrical circuit protection |
| Installation type | Compatible electrical distribution boards and switchgear assemblies |
| Product construction | Moulded case circuit breaker |
The ABB EPX-XT2S-TM1254 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution boards.
The circuit breaker has a rated current of 125 A. It is designed to provide protection for appropriately rated electrical circuits, subject to correct cable sizing, load assessment and protective device coordination.
The ABB EPX-XT2S-TM1254 has a specified 50 kA short-circuit breaking capacity. The suitability of this rating must be verified against the installation's operating voltage and prospective short-circuit current.
TMA refers to thermal-magnetic protection. The thermal element provides protection against sustained overload conditions, while the magnetic element provides rapid tripping during short-circuit faults. These complementary functions help protect electrical circuits and connected equipment against excessive current.
A four-pole MCCB enables simultaneous switching of three phase conductors and a neutral conductor. This makes it suitable for three-phase electrical distribution systems where four-pole switching or isolation is required.
The ABB manufacturer order code is 1SDX255116R1. The corresponding product reference is EPX-XT2S-TM1254, identifying the 125 A, four-pole, 50 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.
The product belongs to the ABB SACE Tmax XT2S series and uses the XT2S160 circuit breaker platform. The XT2S160 designation identifies the 160 A frame class, while this particular MCCB has a rated current of 125 A.
Yes. The ABB EPX-XT2S-TM1254 features a thermal-magnetic (TMA) trip unit. Its thermal element responds to sustained overloads, while its magnetic element provides rapid tripping under short-circuit conditions.
This MCCB is typically installed within compatible electrical distribution boards, low-voltage switchgear assemblies and power distribution panels. Its four-pole configuration and compact XT2S construction support integration into suitably configured ABB Protecta Power equipment.
ABB is an established manufacturer of electrical protection and power distribution equipment. The ABB Protecta Power Devices range, including the EPX-XT2S-TM1254 four-pole thermal-magnetic MCCB, provides electrical contractors, panel builders and facilities engineers with dependable circuit protection solutions for commercial and industrial low-voltage distribution systems.