1SDX255114R1 ABB EPX-XT2S-TM0804 80A 4P 50kA MCCB - TMA

1SDX255114R1 ABB EPX-XT2S-TM0804 80A 4P 50kA MCCB – TMA

ABB EPX-XT2S-TM0804 is an 80 A four-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit. Part of the ABB Protecta Power Devices range, it provides thermal overload and instantaneous magnetic short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX255114R1Alt SKU: EPX-XT2S-TM0804MPN: 1SDX255114R1
Price
List Price £666.50 ex VAT
Your Price (ex VAT)
£666.50
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £666.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£666.50

Why Choose the ABB EPX-XT2S-TM0804 80A 4-Pole 50kA MCCB?

The ABB EPX-XT2S-TM0804 is a high-performance 80 A four-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit, this circuit breaker forms part of the ABB Protecta Power Devices range and uses the established ABB SACE Tmax XT2S circuit breaker platform.

Engineered for installations requiring dependable overcurrent protection and substantial fault-current interruption capability, the EPX-XT2S-TM0804 combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection. Its thermal-magnetic operating principle offers straightforward protection configuration without requiring a separate electronic trip-unit power supply, making it a practical choice for professionally designed three-phase electrical distribution systems.

With its 80 A rated current, four-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-TM0804 is suitable for appropriately designed outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. The four-pole arrangement supports coordinated switching of three phase conductors and a neutral conductor where required by the installation design. Supplied under ABB order code 1SDX255114R1, this MCCB provides robust, adjustable thermal-magnetic circuit protection for demanding low-voltage applications.

Key Advantages

  • 80 A rated current provides dependable overcurrent protection for appropriately designed electrical distribution circuits.
  • Four-pole (4P) configuration supports coordinated switching of three phase conductors and a neutral conductor.
  • 50 kA short-circuit breaking capacity offers substantial fault-current interruption capability.
  • TMA thermal-magnetic trip unit combines overload and short-circuit protection in a single MCCB.
  • Adjustable thermal overload protection enables the protective threshold to be selected according to circuit requirements.
  • Adjustable magnetic short-circuit protection provides flexibility when configuring instantaneous fault protection.
  • Magnetic setting range of 400–800 A supports appropriate short-circuit protection coordination.
  • Inverse-time thermal response helps protect conductors against overheating caused by sustained overloads.
  • Thermal-magnetic operation does not require a separate electronic trip-unit power supply.
  • ABB SACE Tmax XT2S construction combines established switching technology with compact moulded case design.
  • S breaking-capacity classification offers a higher specified breaking capacity than corresponding XT2N 36 kA configurations.
  • XT2 160 A frame platform provides a robust mechanical basis for the 80 A protective configuration.
  • Four-pole switching is useful in installations requiring neutral isolation alongside phase switching.
  • Manual toggle-operated mechanism enables straightforward local operation and resetting.
  • Designed for integration into compatible ABB Protecta Power distribution systems.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT2S moulded case circuit breaker platform.
  • 80 A rated current.
  • Four-pole (4P) configuration.
  • 50 kA specified short-circuit breaking capacity.
  • TMA adjustable thermal-magnetic protection release.
  • Thermal overload protection for sustained excessive current.
  • Adjustable thermal protection threshold for appropriate circuit protection settings.
  • Inverse-time thermal operating characteristic.
  • Instantaneous magnetic short-circuit protection.
  • Adjustable magnetic protection threshold.
  • Magnetic adjustment range: 5–10 × In.
  • Magnetic short-circuit setting range: 400–800 A.
  • Rapid magnetic tripping when the selected operating threshold is reached.
  • Thermal-magnetic operating technology without a separate electronic protection supply.
  • XT2S 160 A frame family with an 80 A rated protective release.
  • Four-pole construction for appropriately designed three-phase and neutral distribution arrangements.
  • Compact moulded case design for compatible distribution assemblies.
  • Fixed-mounted circuit breaker platform on the corresponding XT2S TMA configuration.
  • Front-terminal connection arrangement on the corresponding XT2S TMA platform.
  • Manual toggle-operated switching mechanism.
  • Mechanical operating and trip indication through the breaker mechanism.
  • Designed in accordance with IEC/EN 60947-2.
  • ABB manufacturer order code: 1SDX255114R1.

Reliable 80A Four-Pole Thermal-Magnetic Protection with 50kA Breaking Capacity

The ABB EPX-XT2S-TM0804 combines the mechanical switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an adjustable TMA thermal-magnetic protection release. This arrangement provides protection against sustained overload conditions and short-circuit faults, helping protect electrical conductors, connected equipment and distribution infrastructure against excessive current.

The thermal overload protection function responds to current flowing above the selected protection threshold for a sustained period. Its inverse-time operating characteristic means that larger overload currents generally result in faster tripping. This helps protect conductors against overheating while accommodating appropriate operating conditions within the electrical circuit's design limits.

The adjustable thermal element allows the overload protection threshold to be selected according to the connected circuit's requirements. The chosen setting must be compatible with conductor current-carrying capacity, expected load, installation conditions and the manufacturer's time-current characteristics. The precise thermal adjustment range for the supplied 80 A four-pole configuration should be confirmed against ABB's technical documentation before commissioning.

The magnetic short-circuit protection function provides rapid tripping when the current reaches the selected magnetic operating threshold. For the corresponding 80 A XT2S TMA release, the magnetic protection range is 400–800 A, equivalent to 5–10 times the rated current. This allows the magnetic threshold to be selected with regard to the installation's fault-current conditions and the coordination requirements of other protective devices.

The TMA thermal-magnetic trip unit provides a practical alternative to electronic protection releases. It uses thermal and magnetic operating principles rather than electronic sensing and processing, and it does not require a separate electronic trip-unit power supply. Unlike an electronic LSI release, the TMA arrangement does not provide an independently adjustable short-time delayed short-circuit protection function.

A major advantage of the XT2S breaking-capacity classification is its specified 50 kA short-circuit breaking capacity. This provides greater fault-interruption capability than corresponding XT2N configurations specified at 36 kA under the relevant reference conditions. The higher breaking capacity can be particularly useful where the circuit is located relatively close to a transformer, main switchboard or other supply point with substantial prospective fault current.

The corresponding ABB SACE Tmax XT2S IEC breaker platform has a 50 kA ultimate short-circuit breaking capacity at 415 V AC. However, the available breaking capacity varies with operating voltage. The installation's calculated prospective short-circuit current must therefore be compared with the applicable voltage-dependent rating, and the relevant ultimate and service breaking capacities should be checked against ABB's published technical data.

The four-pole configuration enables coordinated switching of four conductors, typically the three phase conductors and a neutral conductor in a suitably designed three-phase distribution system. This can be particularly valuable where the electrical installation requires neutral isolation alongside phase switching. However, the presence of a fourth pole does not automatically establish the neutral conductor's overcurrent protection characteristics. The exact neutral-pole arrangement must be verified against the manufacturer's technical information.

The ABB SACE Tmax XT2 160 A frame platform provides the mechanical foundation for the 80 A TMA configuration. Although the XT2 frame family supports ratings up to 160 A, the EPX-XT2S-TM0804 is specifically an 80 A rated protective device. The frame rating must not be confused with the rated current of the installed protection release or the permissible current of the protected circuit.

As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0804 is intended for installation in compatible distribution assemblies. Correct selection of mounting arrangements, cable terminations, enclosure components and protection settings is essential. The standard TMA release provides overload and short-circuit protection rather than residual-current or earth-leakage protection, so any required additional protective functions must be specified separately.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 80 A thermal-magnetic protection.
  • Four-pole circuits requiring coordinated switching of phase and neutral conductors.
  • Distribution circuits requiring a 50 kA short-circuit breaking capacity.
  • Commercial building electrical sub-distribution boards.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Building services and mechanical plant power distribution.
  • Electrical installations requiring adjustable overload and magnetic short-circuit protection.
  • Electrical refurbishment and distribution board upgrades involving compatible ABB MCCBs.
  • Professional installations requiring compact, high-breaking-capacity four-pole circuit protection.

Technical Specifications

Product group Protecta Power Devices
Product reference EPX-XT2S-TM0804
ABB order code 1SDX255114R1
Product type Moulded case circuit breaker (MCCB)
Series SACE Tmax XT2 / Protecta Power
Circuit breaker designation XT2S
Rated current (In) 80 A
Number of poles 4
Pole configuration 4P
Specified short-circuit breaking capacity 50 kA
Corresponding XT2S IEC breaker breaking capacity 50 kA at 415 V AC
Breaking-capacity classification S
Trip unit type TMA adjustable thermal-magnetic
Protection technology Thermal-magnetic overcurrent release
Overload protection Adjustable thermal
Thermal operating characteristic Inverse-time
Thermal setting range Confirm against the exact ABB trip-unit documentation
Short-circuit protection Adjustable instantaneous magnetic
Magnetic protection adjustment 5–10 × In
Magnetic short-circuit setting range 400–800 A
Magnetic operating characteristic Rapid tripping at the selected threshold
Trip-unit adjustment method Mechanical setting controls
Separate electronic trip-unit supply Not required
Frame family XT2S
XT2 frame rating 160 A
Rated protective current 80 A
Corresponding XT2S platform operational voltage Up to 690 V AC
Corresponding XT2S platform mounting Fixed
Corresponding XT2S platform terminals Front terminals
Operating mechanism Manual toggle-operated circuit breaker
Switching arrangement Four-pole simultaneous operation
Neutral-pole protection Confirm the exact neutral arrangement against ABB technical documentation
Applicable circuit breaker standard IEC/EN 60947-2
Application Low-voltage electrical distribution
Typical electrical system Three-phase AC distribution with four-pole switching

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0804 used for?

The ABB EPX-XT2S-TM0804 is an 80 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses a TMA thermal-magnetic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT2S-TM0804?

The EPX-XT2S-TM0804 has an 80 A rated current. It is intended for appropriately designed electrical circuits where the conductor ratings, expected load and protection characteristics are compatible with the circuit breaker.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT2S-TM0804 has a specified 50 kA short-circuit breaking capacity. The corresponding XT2S IEC breaker platform has a 50 kA ultimate breaking capacity at 415 V AC. The applicable rating must be checked against the installation voltage and prospective fault current.

What does TMA mean on an ABB MCCB?

TMA identifies an adjustable thermal-magnetic trip unit. It combines thermal protection against sustained overloads with instantaneous magnetic protection against short-circuit currents. The protection thresholds can be configured within the adjustment ranges applicable to the exact release.

What is the magnetic short-circuit adjustment range?

The corresponding 80 A XT2S TMA release provides a magnetic short-circuit adjustment range of 400–800 A, equivalent to 5–10 times the rated current. The setting should be selected according to the installation's fault-current conditions and protection coordination requirements.

Can the thermal overload protection be adjusted?

Yes. The TMA thermal-magnetic trip unit provides adjustable thermal overload protection. The available settings for the exact supplied configuration should be confirmed against ABB's technical documentation, and the selected threshold must suit the conductor ratings and expected circuit load.

What is the difference between XT2S and XT2N MCCBs?

XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding Protecta Power XT2S configurations are specified at 50 kA, compared with 36 kA for XT2N configurations under the relevant reference conditions. The correct selection depends on the installation voltage and prospective short-circuit current.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables coordinated switching of four conductors, typically the three phase conductors and a neutral conductor in a three-phase electrical distribution system. This is useful where neutral isolation is required, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.

Does the ABB EPX-XT2S-TM0804 provide earth-leakage protection?

The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible arrangement must be specified.

What is the difference between the 80A rating and the 160A frame rating?

The 80 A rating identifies the circuit breaker's rated protective current, while the 160 A frame rating identifies the current rating of the XT2 platform. The EPX-XT2S-TM0804 is an 80 A protective device and must not be treated as a 160 A rated circuit breaker.

What is the ABB order code for the EPX-XT2S-TM0804?

The ABB manufacturer order code is 1SDX255114R1. The corresponding product reference is EPX-XT2S-TM0804, identifying the 80 A, four-pole, 50 kA TMA thermal-magnetic MCCB within the ABB Protecta Power Devices range.

Trusted ABB Thermal-Magnetic Circuit Protection for Professional Installations

The ABB EPX-XT2S-TM0804 combines an 80 A four-pole configuration, 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection in a robust SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides dependable overload and short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.