ABB EPX-XT2S-TM0634 is a 63 A four-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit. Part of the ABB Protecta Power Devices range, it provides thermal overload and adjustable instantaneous magnetic short-circuit protection for commercial and industrial low-voltage distribution systems.
£575.92
The ABB EPX-XT2S-TM0634 is a high-performance 63 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit, this circuit breaker forms part of the ABB Protecta Power Devices range and uses ABB's established SACE Tmax XT2S circuit breaker technology.
Engineered for electrical installations requiring dependable overcurrent protection and substantial fault-current interruption capability, the EPX-XT2S-TM0634 combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection. Its thermal-magnetic operating principle provides a practical alternative to electronic trip releases, offering straightforward protection configuration without requiring a separate electronic trip-unit power supply.
With its 63 A rated current, four-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-TM0634 is particularly suitable for appropriately designed three-phase distribution circuits where switching of the neutral conductor is also required. Supplied under ABB order code 1SDX255113R1, this MCCB provides a robust circuit protection solution for compatible ABB Protecta Power distribution boards, commercial switchgear and industrial electrical panels.
The ABB EPX-XT2S-TM0634 combines the mechanical switching and fault-interruption capabilities of the ABB SACE Tmax XT2S platform with an adjustable TMA thermal-magnetic trip unit. This combination provides protection against two principal overcurrent conditions: sustained overloads and short circuits. By interrupting the affected circuit when the relevant operating threshold is reached, the MCCB helps protect electrical conductors, connected equipment and distribution infrastructure.
The thermal overload protection function responds to excessive current flowing for a sustained period. Its inverse-time operating characteristic means that higher overload currents generally result in faster tripping. Adjustable thermal protection allows the operating threshold to be selected in accordance with conductor ratings, expected circuit loading and the requirements of the electrical installation. The exact thermal adjustment positions for the supplied configuration should be confirmed using ABB's technical documentation.
The magnetic short-circuit protection function provides rapid tripping when the current reaches the selected magnetic threshold. For the corresponding 63 A XT2S TMA release, the magnetic setting range is 315–630 A, equivalent to 5–10 times the rated current. This adjustment provides flexibility when configuring the protective response to short-circuit conditions and coordinating the MCCB with other protective devices.
The TMA thermal-magnetic trip unit offers a practical alternative to electronic protection releases. It uses thermal and magnetic operating principles rather than electronic sensing and processing, and it does not require a separate electronic trip-unit power supply. Unlike an electronic LSI release, a conventional TMA trip unit does not provide a separately adjustable short-time delayed short-circuit protection function.
A significant advantage of the XT2S breaking-capacity classification is its specified 50 kA short-circuit breaking capacity. This provides greater fault-interruption capability than corresponding XT2N configurations specified at 36 kA under the relevant reference conditions. Higher breaking capacity can be particularly valuable where prospective short-circuit currents are substantial, such as distribution circuits located relatively close to a transformer or main electrical supply.
Although the corresponding ABB SACE Tmax XT2S platform supports operating voltages up to 690 V AC, its short-circuit breaking capacity depends on the system voltage. The specified 50 kA rating must therefore be checked against the installation's actual operating voltage and calculated prospective fault current. The applicable ultimate and service breaking capacities should be verified using ABB's published technical data before the device is selected.
The four-pole construction enables simultaneous switching of four conductors, typically the three phase conductors and a neutral conductor in an appropriately designed three-phase distribution system. This arrangement is useful where the electrical installation requires neutral isolation alongside phase switching. However, four-pole switching does not automatically establish the neutral conductor's overcurrent protection characteristics. The exact neutral-pole arrangement must be verified against ABB's technical documentation.
The ABB SACE Tmax XT2 160 A frame platform provides the mechanical foundation for the 63 A TMA configuration. Although the XT2 frame family supports ratings up to 160 A, the EPX-XT2S-TM0634 is specifically a 63 A rated protective device. The frame rating must not be confused with the rated current of the installed trip unit or the permissible current of the protected circuit.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0634 is intended for integration into compatible distribution assemblies. Its 120 mm nominal four-pole width supports compact installation, while the corresponding fixed-mounted XT2S configuration uses front terminals. Correct selection of mounting accessories, cable terminations, enclosure arrangements and protection settings remains essential.
The standard TMA release provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where additional earth-leakage protection is required, an appropriate protective device or compatible arrangement must be specified separately. Final circuit breaker selection should be supported by fault-level calculations, conductor sizing, protective device coordination studies and the applicable electrical installation standards.
| Product group | Protecta Power Devices |
|---|---|
| Product reference | EPX-XT2S-TM0634 |
| ABB order code | 1SDX255113R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Series | SACE Tmax XT2 / Protecta Power |
| Circuit breaker designation | XT2S |
| Rated current (In) | 63 A |
| Number of poles | 4 |
| Pole configuration | 4P |
| Specified short-circuit breaking capacity | 50 kA |
| Breaking-capacity classification | S |
| Trip unit type | TMA adjustable thermal-magnetic |
| Protection technology | Thermal-magnetic overcurrent release |
| Overload protection | Adjustable thermal |
| Thermal operating characteristic | Inverse-time |
| Short-circuit protection | Adjustable instantaneous magnetic |
| Magnetic protection adjustment | 5–10 × In |
| Magnetic short-circuit setting range | 315–630 A |
| Magnetic operating characteristic | Rapid tripping at the selected threshold |
| Trip-unit adjustment method | Mechanical setting controls |
| Separate electronic trip-unit supply | Not required |
| Frame family | XT2S |
| XT2 frame rating | 160 A |
| Rated protective current | 63 A |
| Nominal four-pole width | 120 mm |
| Corresponding XT2S platform operational voltage | Up to 690 V AC |
| Corresponding XT2S platform mounting | Fixed |
| Corresponding XT2S platform terminals | Front terminals |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Switching arrangement | Four-pole simultaneous operation |
| Neutral-pole protection | Confirm the exact neutral arrangement against ABB technical documentation |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Application | Low-voltage electrical distribution |
| Typical electrical system | Three-phase AC distribution with four-pole switching |
The ABB EPX-XT2S-TM0634 is a 63 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses a TMA thermal-magnetic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-TM0634 has a 63 A rated current. It is intended for appropriately designed electrical circuits where the conductor ratings, expected load and protection characteristics are compatible with the circuit breaker.
The ABB EPX-XT2S-TM0634 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the circuit breaker.
TMA identifies an adjustable thermal-magnetic trip unit. It combines thermal protection against sustained overloads with magnetic protection against short-circuit currents, allowing the protective response to be configured according to the circuit requirements.
The corresponding 63 A XT2S TMA release provides a magnetic short-circuit adjustment range of 315–630 A, equivalent to 5–10 times the rated current. The appropriate setting must be selected according to the installation's fault-current conditions and protection coordination requirements.
Yes. The TMA thermal-magnetic trip unit provides adjustable thermal overload protection. The available settings for the exact supplied configuration should be confirmed against ABB's technical documentation, and the selected threshold must suit the conductor ratings and expected circuit load.
XT2S and XT2N identify different breaking-capacity variants within the ABB SACE Tmax XT2 range. Corresponding Protecta Power XT2S configurations are specified at 50 kA, compared with 36 kA for XT2N configurations under the relevant reference conditions. The correct selection depends on the installation voltage and prospective short-circuit current.
The four-pole (4P) configuration enables simultaneous switching of four conductors, typically the three phase conductors and a neutral conductor in a three-phase electrical distribution system. This makes the MCCB suitable for installations requiring four-pole switching, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.
The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.
The ABB manufacturer order code is 1SDX255113R1. The corresponding product reference is EPX-XT2S-TM0634, identifying the 63 A, four-pole, 50 kA TMA thermal-magnetic MCCB within the ABB Protecta Power Devices range.
The ABB EPX-XT2S-TM0634 combines a 63 A four-pole configuration, 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection in a compact SACE Tmax XT2S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides dependable overload and short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.