ABB EPX-XT2S-TM0504 is a 50 A four-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution.
£575.92
The ABB EPX-XT2S-TM0504 is a 50 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection, this circuit breaker is suitable for commercial, industrial and infrastructure electrical installations.
Part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0504 belongs to the ABB SACE Tmax XT2S circuit breaker family. Its thermal-magnetic trip unit combines thermal overload protection with magnetic short-circuit protection, helping protect conductors, electrical equipment and distribution circuits against abnormal current conditions.
With its 50 A rated current, four-pole configuration and 50 kA breaking capacity, the EPX-XT2S-TM0504 provides a practical solution for three-phase electrical distribution systems requiring four-pole switching. Its compact XT2 platform and established protection technology make it suitable for electrical contractors, panel builders and maintenance engineers working with compatible ABB Protecta Power assemblies.
The ABB EPX-XT2S-TM0504 uses a TMA thermal-magnetic protection release to respond to overload and short-circuit conditions. The thermal element provides a time-dependent response to sustained excessive currents, helping protect conductors and connected equipment against overheating. The magnetic element provides rapid tripping when the current reaches the applicable short-circuit protection threshold. Protection settings should be selected according to ABB's technical documentation and the requirements of the electrical installation.
The ABB SACE Tmax XT2S platform combines dependable circuit protection with a compact MCCB design. Featuring a 50 A rated current, four-pole construction and 50 kA breaking capacity, the EPX-XT2S-TM0504 is suitable for appropriately designed distribution circuits requiring four-pole switching and substantial fault interruption capability. Correct selection must consider the operating voltage, prospective short-circuit current, conductor ratings, neutral switching requirements and protective coordination.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker family | SACE Tmax XT |
| Series | XT2S |
| ABB order code | 1SDX255112R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 50 A |
| Number of poles | 4 |
| Short-circuit breaking capacity | 50 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Frame family | XT2 |
| Breaking capacity class | S |
| Operating mechanism | Manual switching with automatic protective tripping |
| Application | Low-voltage three-phase electrical distribution |
| Circuit breaker standard | IEC 60947-2 |
The ABB EPX-XT2S-TM0504 is a 50 A four-pole MCCB used to protect low-voltage electrical distribution circuits against overloads and short circuits.
The EPX-XT2S-TM0504 has a rated current of 50 A. The connected load, conductor ratings and installation conditions must be considered when selecting the circuit breaker.
The EPX-XT2S-TM0504 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation voltage must be checked against the prospective fault current.
TMA identifies an adjustable thermal-magnetic protection release. Thermal protection responds to sustained overload currents, while magnetic protection responds to short-circuit faults.
The TMA designation indicates adjustable thermal-magnetic protection functionality. The exact available settings and adjustment ranges should be confirmed against ABB's technical documentation for the supplied release.
Yes. The EPX-XT2S-TM0504 has a four-pole (4P) configuration suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching.
The EPX-XT2S-TM0504 belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT2S circuit breaker platform.
The S designation identifies a breaking capacity class within the ABB SACE Tmax XT2 circuit breaker family. The EPX-XT2S-TM0504 has a specified breaking capacity of 50 kA.
A three-pole MCCB switches three phase conductors, while a four-pole MCCB provides an additional switching pole, commonly used for the neutral conductor. The correct configuration depends on the electrical installation and earthing arrangement.
Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its electrical ratings, protection characteristics and installation requirements match the application.
The ABB order code is 1SDX255112R1, identifying this model within the ABB Protecta Power Devices range.
ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, contractors and industrial maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT2S-TM0504 combines a 50 A rated current, four-pole configuration and 50 kA breaking capacity with TMA thermal-magnetic protection, making it a practical choice for commercial and industrial electrical distribution.