1SDX255112R1 ABB EPX-XT2S-TM0504 50A 4-Pole 50kA TMA Moulded Case Circuit Breaker

1SDX255112R1 ABB EPX-XT2S-TM0504 50A 4-Pole 50kA TMA Moulded Case Circuit Breaker

ABB EPX-XT2S-TM0504 is a 50 A four-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution.

SKU: 1SDX255112R1Alt SKU: EPX-XT2S-TM0504MPN: 1SDX255112R1
Price
List Price £575.92 ex VAT
Your Price (ex VAT)
£575.92
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £575.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£575.92

Why Choose the ABB EPX-XT2S-TM0504 50A 4-Pole 50kA MCCB?

The ABB EPX-XT2S-TM0504 is a 50 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection, this circuit breaker is suitable for commercial, industrial and infrastructure electrical installations.

Part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0504 belongs to the ABB SACE Tmax XT2S circuit breaker family. Its thermal-magnetic trip unit combines thermal overload protection with magnetic short-circuit protection, helping protect conductors, electrical equipment and distribution circuits against abnormal current conditions.

With its 50 A rated current, four-pole configuration and 50 kA breaking capacity, the EPX-XT2S-TM0504 provides a practical solution for three-phase electrical distribution systems requiring four-pole switching. Its compact XT2 platform and established protection technology make it suitable for electrical contractors, panel builders and maintenance engineers working with compatible ABB Protecta Power assemblies.

Key Advantages

  • 50 A rated current suitable for appropriately designed commercial and industrial distribution circuits.
  • 50 kA breaking capacity provides substantial short-circuit interruption capability.
  • Four-pole configuration supports three-phase distribution systems requiring a fourth switching pole.
  • TMA thermal-magnetic trip unit combines overload and short-circuit protection.
  • Thermal overload protection helps reduce the risk of conductor overheating during sustained excessive current.
  • Magnetic short-circuit protection provides rapid tripping during sufficiently high fault currents.
  • Adjustable protection functionality supports suitable circuit protection settings.
  • ABB SACE Tmax XT2S technology provides dependable switching and protective operation.
  • Compact XT2 frame family supports efficient integration into compatible electrical assemblies.
  • Manual switching with automatic protective tripping combines circuit control and fault protection.
  • Protecta Power application supports integration into compatible ABB distribution equipment.

Key Features

  • ABB EPX-XT2S-TM0504 moulded case circuit breaker.
  • 50 A rated current.
  • Four-pole (4P) configuration.
  • 50 kA short-circuit breaking capacity.
  • ABB SACE Tmax XT2S circuit breaker platform.
  • TMA thermal-magnetic protection release.
  • Thermal protection against sustained overload currents.
  • Magnetic protection against short-circuit faults.
  • Automatic protective tripping under applicable overcurrent conditions.
  • Manual operating mechanism for circuit switching.
  • Four-pole switching arrangement for suitable three-phase distribution systems.
  • S breaking capacity class within the ABB Tmax XT2 family.
  • Designed for low-voltage AC electrical distribution.
  • Suitable for compatible ABB Protecta Power distribution assemblies.
  • Applicable to commercial and industrial switchgear installations.

Thermal-Magnetic Protection for Four-Pole Electrical Distribution

The ABB EPX-XT2S-TM0504 uses a TMA thermal-magnetic protection release to respond to overload and short-circuit conditions. The thermal element provides a time-dependent response to sustained excessive currents, helping protect conductors and connected equipment against overheating. The magnetic element provides rapid tripping when the current reaches the applicable short-circuit protection threshold. Protection settings should be selected according to ABB's technical documentation and the requirements of the electrical installation.

The ABB SACE Tmax XT2S platform combines dependable circuit protection with a compact MCCB design. Featuring a 50 A rated current, four-pole construction and 50 kA breaking capacity, the EPX-XT2S-TM0504 is suitable for appropriately designed distribution circuits requiring four-pole switching and substantial fault interruption capability. Correct selection must consider the operating voltage, prospective short-circuit current, conductor ratings, neutral switching requirements and protective coordination.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase distribution systems requiring four-pole switching.
  • 50 A outgoing feeders and distribution circuits.
  • Sub-distribution panels in commercial buildings.
  • Industrial control panel supply circuits.
  • Manufacturing and production facilities.
  • Warehouses and logistics installations.
  • Commercial building electrical infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Distribution circuits requiring thermal overload and magnetic short-circuit protection.
  • Electrical maintenance, refurbishment and distribution system upgrades.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT2S
ABB order code 1SDX255112R1
Product type Moulded case circuit breaker (MCCB)
Rated current 50 A
Number of poles 4
Short-circuit breaking capacity 50 kA
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Frame family XT2
Breaking capacity class S
Operating mechanism Manual switching with automatic protective tripping
Application Low-voltage three-phase electrical distribution
Circuit breaker standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0504 used for?

The ABB EPX-XT2S-TM0504 is a 50 A four-pole MCCB used to protect low-voltage electrical distribution circuits against overloads and short circuits.

What is the rated current of the EPX-XT2S-TM0504?

The EPX-XT2S-TM0504 has a rated current of 50 A. The connected load, conductor ratings and installation conditions must be considered when selecting the circuit breaker.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2S-TM0504 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation voltage must be checked against the prospective fault current.

What does TMA mean on the ABB EPX-XT2S-TM0504?

TMA identifies an adjustable thermal-magnetic protection release. Thermal protection responds to sustained overload currents, while magnetic protection responds to short-circuit faults.

Does the ABB EPX-XT2S-TM0504 provide adjustable protection?

The TMA designation indicates adjustable thermal-magnetic protection functionality. The exact available settings and adjustment ranges should be confirmed against ABB's technical documentation for the supplied release.

Is the EPX-XT2S-TM0504 a four-pole circuit breaker?

Yes. The EPX-XT2S-TM0504 has a four-pole (4P) configuration suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching.

What ABB circuit breaker series does this model belong to?

The EPX-XT2S-TM0504 belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT2S circuit breaker platform.

What does the S designation mean in XT2S?

The S designation identifies a breaking capacity class within the ABB SACE Tmax XT2 circuit breaker family. The EPX-XT2S-TM0504 has a specified breaking capacity of 50 kA.

What is the difference between a three-pole and four-pole MCCB?

A three-pole MCCB switches three phase conductors, while a four-pole MCCB provides an additional switching pole, commonly used for the neutral conductor. The correct configuration depends on the electrical installation and earthing arrangement.

Can the EPX-XT2S-TM0504 be used in industrial distribution panels?

Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its electrical ratings, protection characteristics and installation requirements match the application.

What is the ABB order code for the EPX-XT2S-TM0504?

The ABB order code is 1SDX255112R1, identifying this model within the ABB Protecta Power Devices range.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, contractors and industrial maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT2S-TM0504 combines a 50 A rated current, four-pole configuration and 50 kA breaking capacity with TMA thermal-magnetic protection, making it a practical choice for commercial and industrial electrical distribution.