Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT2S-TM0324 is a 32 A four-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring TMA thermal-magnetic overload and short-circuit protection for low-voltage three-phase electrical distribution systems.
£575.92
The ABB EPX-XT2S-TM0324 is a high-performance 32 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S platform, combining compact construction, thermal-magnetic protection technology and substantial short-circuit interruption capability for commercial and industrial electrical installations.
Featuring TMA thermal-magnetic protection, the EPX-XT2S-TM0324 combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect electrical cables and connected equipment against overheating, while the magnetic element provides rapid tripping when short-circuit current reaches the applicable protection threshold. This established protection technology provides dependable operation without requiring an electronic trip unit or external auxiliary power supply.
With a rated current of 32 A, a four-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for protecting appropriately designed three-phase distribution circuits incorporating a neutral conductor. Its compact ABB XT2S construction supports integration into compatible ABB Protecta Power distribution boards, making it a practical choice for electrical contractors, switchboard manufacturers, consulting engineers and maintenance professionals.
The ABB EPX-XT2S-TM0324 provides electrical protection through the combined operation of thermal and magnetic trip mechanisms. During sustained overload conditions, the thermal protection element responds to excessive current according to its time-current characteristics, helping reduce the risk of overheating in electrical cables, terminals and connected equipment. During short-circuit conditions, the magnetic protection element responds rapidly when fault current reaches its operating threshold, initiating circuit interruption to reduce the consequences of electrical faults.
The TMA thermal-magnetic protection designation identifies the breaker within ABB's Protecta Power range of conventional overload and short-circuit protective devices. Thermal-magnetic protection is particularly useful where straightforward operation and established trip characteristics are preferred. The exact adjustment facilities and operating thresholds depend on the supplied breaker configuration and should be confirmed from the manufacturer's markings and technical documentation. This ensures that circuit protection can be coordinated correctly with cable ratings, connected equipment and upstream protective devices.
The ABB SACE Tmax XT2S platform combines compact moulded case construction with a specified 50 kA short-circuit breaking capacity, making the EPX-XT2S-TM0324 suitable for appropriately engineered distribution systems requiring substantial fault interruption capability. Its four-pole configuration supports coordinated switching of three phase conductors and a neutral conductor, making it particularly useful in distribution assemblies where four-pole isolation is required. The applicable operating voltage, prospective short-circuit current, neutral conductor arrangement and protection coordination should always be verified before installation.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT2 |
| Product model | EPX-XT2S-TM0324 |
| ABB order code | 1SDX255110R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Performance designation | XT2S |
| Frame designation | XT2S 160 |
| Frame current class | 160 A |
| Rated current (In) | 32 A |
| Number of poles | 4 |
| Specified short-circuit breaking capacity | 50 kA |
| Trip unit technology | Thermal-magnetic |
| Protecta Power catalogue trip designation | TMA |
| Overload protection | Thermal trip mechanism |
| Short-circuit protection | Magnetic trip mechanism |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase with neutral |
| Switching configuration | Four-pole |
| Operating mechanism | Manual toggle operation |
| Primary function | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT2S-TM0324 is a 32 A four-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT2S-TM0324 has a 32 A rated current and belongs to the ABB SACE Tmax XT2S platform, which uses a 160 A frame class. The frame class identifies the circuit breaker platform rather than the rated current of this individual device.
The EPX-XT2S-TM0324 has a specified 50 kA short-circuit breaking capacity. The applicable operating voltage and manufacturer short-circuit performance conditions must be verified against the prospective fault current at the installation location.
TMA is the thermal-magnetic protection designation used in the ABB Protecta Power product description. Thermal-magnetic circuit breakers combine a thermal element for overload protection with a magnetic element for short-circuit protection. The exact adjustment facilities and trip thresholds should be confirmed for the supplied breaker.
ABB thermal-magnetic circuit breakers are available with different protection adjustment arrangements. The exact thermal and magnetic adjustment facilities for the EPX-XT2S-TM0324 should be confirmed from the markings and manufacturer documentation supplied with the device before selecting protection settings.
The four-pole configuration provides coordinated switching of three phase conductors and a neutral conductor. It is suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. The neutral pole's protection characteristics should be verified for the selected breaker configuration.
XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding ABB Protecta Power XT2N devices are specified at 36 kA, while XT2S versions are specified at 50 kA. The appropriate breaker should be selected according to the prospective fault current and applicable operating voltage.
Yes. The EPX-XT2S-TM0324 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection requirements should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, dependable thermal-magnetic operation and substantial short-circuit interruption capability for modern low-voltage power systems.