1SDX255110R1 ABB EPX-XT2S-TM0324 32A 4-Pole 50kA TMA Thermal-Magnetic MCCB

1SDX255110R1 ABB EPX-XT2S-TM0324 32A 4-Pole 50kA TMA Thermal-Magnetic MCCB

ABB EPX-XT2S-TM0324 is a 32 A four-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring TMA thermal-magnetic overload and short-circuit protection for low-voltage three-phase electrical distribution systems.

SKU: 1SDX255110R1Alt SKU: EPX-XT2S-TM0324MPN: 1SDX255110R1
Price
List Price £575.92 ex VAT
Your Price (ex VAT)
£575.92
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £575.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£575.92

Why Choose the ABB EPX-XT2S-TM0324 32A 4-Pole 50kA MCCB?

The ABB EPX-XT2S-TM0324 is a high-performance 32 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S platform, combining compact construction, thermal-magnetic protection technology and substantial short-circuit interruption capability for commercial and industrial electrical installations.

Featuring TMA thermal-magnetic protection, the EPX-XT2S-TM0324 combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect electrical cables and connected equipment against overheating, while the magnetic element provides rapid tripping when short-circuit current reaches the applicable protection threshold. This established protection technology provides dependable operation without requiring an electronic trip unit or external auxiliary power supply.

With a rated current of 32 A, a four-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for protecting appropriately designed three-phase distribution circuits incorporating a neutral conductor. Its compact ABB XT2S construction supports integration into compatible ABB Protecta Power distribution boards, making it a practical choice for electrical contractors, switchboard manufacturers, consulting engineers and maintenance professionals.

Key Advantages

  • 32 A rated current: Suitable for protecting appropriately designed low-voltage electrical distribution circuits.
  • Four-pole construction: Provides coordinated switching of three phase conductors and a neutral conductor.
  • 50 kA breaking capacity: Offers substantial short-circuit interruption capability for installations with elevated prospective fault currents.
  • ABB TMA thermal-magnetic protection: Combines overload and short-circuit protection within one compact circuit breaker.
  • Thermal overload protection: Helps prevent excessive heating of cables and connected equipment during sustained overload conditions.
  • Magnetic short-circuit protection: Provides rapid fault interruption when current reaches the applicable magnetic trip threshold.
  • Conventional protection technology: Uses established thermal and electromagnetic operating principles.
  • No auxiliary power required: Basic thermal-magnetic protection operates independently of an external electronic power supply.
  • ABB SACE Tmax XT2S platform: Uses established ABB circuit breaker technology for reliable electrical protection.
  • Compact installation format: Helps optimise available space within compatible distribution assemblies.
  • Four-pole switching capability: Suitable for installations requiring coordinated phase and neutral conductor switching.
  • Protecta Power integration: Designed for use in appropriately configured ABB Protecta Power distribution boards.
  • Versatile applications: Suitable for commercial distribution, industrial panels and building services installations.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Circuit breaker series: ABB SACE Tmax XT2.
  • Performance designation: XT2S.
  • Frame designation: XT2S 160.
  • Rated current: 32 A.
  • Number of poles: 4.
  • Specified short-circuit breaking capacity: 50 kA.
  • Protection technology: Thermal-magnetic.
  • Protecta Power trip designation: TMA.
  • Thermal protection: Overload protection using a thermal trip mechanism.
  • Magnetic protection: Short-circuit protection using an electromagnetic trip mechanism.
  • Frame current class: 160 A.
  • Four-pole switching: Coordinated operation of three phase conductors and a neutral conductor.
  • Manual operation: Front-operated circuit breaker switching mechanism.
  • Trip indication: Mechanical indication of circuit breaker operating status.
  • Accessory compatibility: Supports appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.
  • Distribution board compatibility: Intended for compatible ABB Protecta Power electrical distribution assemblies.
  • Product family standard: IEC/EN 60947-2.

Reliable Thermal-Magnetic Protection for Four-Pole Electrical Distribution

The ABB EPX-XT2S-TM0324 provides electrical protection through the combined operation of thermal and magnetic trip mechanisms. During sustained overload conditions, the thermal protection element responds to excessive current according to its time-current characteristics, helping reduce the risk of overheating in electrical cables, terminals and connected equipment. During short-circuit conditions, the magnetic protection element responds rapidly when fault current reaches its operating threshold, initiating circuit interruption to reduce the consequences of electrical faults.

The TMA thermal-magnetic protection designation identifies the breaker within ABB's Protecta Power range of conventional overload and short-circuit protective devices. Thermal-magnetic protection is particularly useful where straightforward operation and established trip characteristics are preferred. The exact adjustment facilities and operating thresholds depend on the supplied breaker configuration and should be confirmed from the manufacturer's markings and technical documentation. This ensures that circuit protection can be coordinated correctly with cable ratings, connected equipment and upstream protective devices.

The ABB SACE Tmax XT2S platform combines compact moulded case construction with a specified 50 kA short-circuit breaking capacity, making the EPX-XT2S-TM0324 suitable for appropriately engineered distribution systems requiring substantial fault interruption capability. Its four-pole configuration supports coordinated switching of three phase conductors and a neutral conductor, making it particularly useful in distribution assemblies where four-pole isolation is required. The applicable operating voltage, prospective short-circuit current, neutral conductor arrangement and protection coordination should always be verified before installation.

Typical Applications

  • ABB Protecta Power distribution boards: Protection of compatible 32 A four-pole outgoing circuits.
  • Commercial electrical distribution: Circuit protection in offices, retail premises and commercial buildings.
  • Industrial electrical panels: Overload and short-circuit protection for appropriately rated three-phase circuits.
  • Sub-distribution boards: Protection of outgoing circuits incorporating a neutral conductor.
  • Electrical control panels: Protection of suitably designed three-phase equipment supply circuits.
  • Building services installations: Electrical protection for ventilation, heating, cooling and mechanical plant equipment.
  • Industrial machinery supplies: Feeder protection where thermal-magnetic trip characteristics are appropriate for connected equipment.
  • Commercial infrastructure: Electrical distribution in warehouses, educational facilities and public buildings.
  • High-fault-level installations: Circuits requiring 50 kA short-circuit interruption capability at the applicable operating voltage.
  • Electrical panel building: Distribution assemblies incorporating the ABB SACE Tmax XT2 circuit breaker platform.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT2
Product model EPX-XT2S-TM0324
ABB order code 1SDX255110R1
Product type Moulded case circuit breaker (MCCB)
Performance designation XT2S
Frame designation XT2S 160
Frame current class 160 A
Rated current (In) 32 A
Number of poles 4
Specified short-circuit breaking capacity 50 kA
Trip unit technology Thermal-magnetic
Protecta Power catalogue trip designation TMA
Overload protection Thermal trip mechanism
Short-circuit protection Magnetic trip mechanism
Electrical system Low-voltage AC distribution
Phase configuration Three-phase with neutral
Switching configuration Four-pole
Operating mechanism Manual toggle operation
Primary function Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0324 used for?

The ABB EPX-XT2S-TM0324 is a 32 A four-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.

What is the rated current of the EPX-XT2S-TM0324?

The EPX-XT2S-TM0324 has a 32 A rated current and belongs to the ABB SACE Tmax XT2S platform, which uses a 160 A frame class. The frame class identifies the circuit breaker platform rather than the rated current of this individual device.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2S-TM0324 has a specified 50 kA short-circuit breaking capacity. The applicable operating voltage and manufacturer short-circuit performance conditions must be verified against the prospective fault current at the installation location.

What does TMA thermal-magnetic protection mean?

TMA is the thermal-magnetic protection designation used in the ABB Protecta Power product description. Thermal-magnetic circuit breakers combine a thermal element for overload protection with a magnetic element for short-circuit protection. The exact adjustment facilities and trip thresholds should be confirmed for the supplied breaker.

Can the overload and short-circuit settings be adjusted?

ABB thermal-magnetic circuit breakers are available with different protection adjustment arrangements. The exact thermal and magnetic adjustment facilities for the EPX-XT2S-TM0324 should be confirmed from the markings and manufacturer documentation supplied with the device before selecting protection settings.

What does the four-pole configuration mean?

The four-pole configuration provides coordinated switching of three phase conductors and a neutral conductor. It is suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. The neutral pole's protection characteristics should be verified for the selected breaker configuration.

What is the difference between ABB XT2N and XT2S circuit breakers?

XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding ABB Protecta Power XT2N devices are specified at 36 kA, while XT2S versions are specified at 50 kA. The appropriate breaker should be selected according to the prospective fault current and applicable operating voltage.

Can the EPX-XT2S-TM0324 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2S-TM0324 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection requirements should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, dependable thermal-magnetic operation and substantial short-circuit interruption capability for modern low-voltage power systems.