1SDX255109R1 ABB EPX-XT2S-TM0254 25A 4-Pole 50kA Thermal-Magnetic MCCB

1SDX255109R1 ABB EPX-XT2S-TM0254 25A 4-Pole 50kA Thermal-Magnetic MCCB

ABB EPX-XT2S-TM0254 is a 25 A four-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, using ABB SACE Tmax XT2S thermal-magnetic protection for low-voltage three-phase electrical distribution systems.

SKU: 1SDX255109R1Alt SKU: EPX-XT2S-TM0254MPN: 1SDX255109R1
Price
List Price £575.92 ex VAT
Your Price (ex VAT)
£575.92
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £575.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£575.92

Why Choose the ABB EPX-XT2S-TM0254 25A 4-Pole 50kA MCCB?

The ABB EPX-XT2S-TM0254 is a compact, high-performance 25 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S 160 A frame platform, combining robust construction, thermal-magnetic protection and substantial short-circuit interruption capability.

Featuring a thermal-magnetic trip unit, the EPX-XT2S-TM0254 provides overload protection and magnetic short-circuit protection for electrical distribution circuits. ABB identifies the corresponding XT2S 25 A four-pole breaker configuration as using TMD thermal-magnetic protection, while the Protecta Power ordering description classifies the device within its TMA range. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption during short-circuit conditions.

With a rated current of 25 A, a four-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for appropriately designed three-phase distribution circuits incorporating a neutral conductor. Its compact 120 mm-wide XT2S four-pole format supports integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, switchboard manufacturers and maintenance engineers.

Key Advantages

  • 25 A rated current: Suitable for protecting appropriately designed low-current electrical distribution circuits.
  • Four-pole construction: Provides coordinated switching of three phase conductors and a neutral conductor.
  • 50 kA breaking capacity: Offers substantial short-circuit interruption capability under the applicable rated conditions.
  • Thermal-magnetic protection: Combines overload and short-circuit protection within one moulded case circuit breaker.
  • Thermal overload response: Helps protect electrical cables and connected equipment against sustained excessive current.
  • Magnetic short-circuit response: Provides rapid tripping when fault current reaches the magnetic protection threshold.
  • Independent protective operation: Basic thermal-magnetic protection does not require an external auxiliary power supply.
  • ABB SACE Tmax XT2S platform: Uses established ABB circuit breaker technology for dependable electrical protection.
  • Compact four-pole format: Helps conserve installation space within compatible distribution assemblies.
  • Neutral conductor switching: Supports electrical installations requiring simultaneous switching of phase and neutral conductors.
  • Protecta Power integration: Designed for appropriately configured ABB Protecta Power distribution boards.
  • Manual circuit operation: Supports switching and isolation procedures in accordance with manufacturer requirements.
  • Versatile applications: Suitable for commercial distribution boards, industrial panels and building services installations.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Circuit breaker series: ABB SACE Tmax XT2.
  • Performance designation: XT2S.
  • Frame designation: XT2S 160.
  • Rated current: 25 A.
  • Number of poles: 4.
  • Specified short-circuit breaking capacity: 50 kA.
  • Protecta Power trip classification: TMA thermal-magnetic MCCB.
  • Corresponding ABB breaker trip technology: TMD thermal-magnetic.
  • Thermal protection: Overload protection using a thermal trip mechanism.
  • Magnetic protection: Short-circuit protection using an electromagnetic trip mechanism.
  • Frame current class: 160 A.
  • Four-pole switching: Coordinated operation of three phase conductors and a neutral conductor.
  • Nominal device width: 120 mm.
  • Operating mechanism: Manual front-operated toggle mechanism.
  • Trip indication: Mechanical indication of a tripped condition.
  • Accessory compatibility: Supports appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.
  • Distribution board compatibility: Intended for compatible ABB Protecta Power assemblies.
  • Product family standard: IEC/EN 60947-2.

Reliable Thermal-Magnetic Protection for Four-Pole Electrical Distribution

The ABB EPX-XT2S-TM0254 uses thermal and magnetic trip mechanisms to protect electrical circuits against abnormal current conditions. During sustained overloads, the thermal protection element responds to excessive current according to its time-current characteristics, helping reduce the risk of overheating in cables, terminals and connected equipment. During short-circuit conditions, the magnetic protection element responds rapidly when fault current reaches the applicable trip threshold, initiating circuit interruption to reduce the consequences of electrical faults.

The corresponding ABB XT2S 25 A four-pole breaker uses TMD thermal-magnetic protection, which provides conventional overload and short-circuit protection characteristics. The distinction between the Protecta Power TMA ordering classification and the underlying TMD breaker designation is important when reviewing technical documentation or selecting replacement components. Protection settings and trip characteristics should be confirmed against the markings and manufacturer documentation for the supplied device rather than assuming that every TMA-labelled Protecta Power breaker has identical adjustment capabilities.

The ABB SACE Tmax XT2S platform combines compact construction with a specified 50 kA short-circuit breaking capacity, making this device suitable for appropriately engineered electrical distribution systems requiring substantial fault interruption capability. Its four-pole design supports coordinated switching of three phase conductors and a neutral conductor. Electrical engineers should verify the applicable operating voltage, prospective short-circuit current, neutral protection requirements and coordination with upstream and downstream protective devices before installation.

Typical Applications

  • ABB Protecta Power distribution boards: Protection of compatible 25 A four-pole outgoing circuits.
  • Commercial electrical distribution: Circuit protection in offices, retail premises and commercial buildings.
  • Industrial electrical panels: Overload and short-circuit protection for appropriately rated three-phase circuits.
  • Sub-distribution boards: Protection of outgoing circuits incorporating a neutral conductor.
  • Electrical control panels: Protection of suitably designed three-phase equipment supply circuits.
  • Building services installations: Electrical protection for ventilation, heating, cooling and mechanical plant equipment.
  • Industrial machinery supplies: Feeder protection where the thermal-magnetic trip characteristics are appropriate for connected equipment.
  • Commercial infrastructure: Electrical distribution in warehouses, educational facilities and public buildings.
  • High-fault-level installations: Circuits requiring 50 kA short-circuit interruption capability at the applicable operating voltage.
  • Electrical panel building: Distribution assemblies incorporating the ABB SACE Tmax XT2 circuit breaker platform.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT2
Product model EPX-XT2S-TM0254
ABB order code 1SDX255109R1
Corresponding ABB circuit breaker reference 1SDA067573R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT2S 160
Frame current class 160 A
Rated current (In) 25 A
Number of poles 4
Specified short-circuit breaking capacity 50 kA
Trip unit technology Thermal-magnetic
Protecta Power catalogue designation TMA
Corresponding ABB breaker trip designation TMD
Overload protection Thermal trip mechanism
Short-circuit protection Magnetic trip mechanism
Electrical system Low-voltage AC distribution
Phase configuration Three-phase with neutral
Nominal device width 120 mm
Operating mechanism Manual toggle operation
Primary function Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0254 used for?

The ABB EPX-XT2S-TM0254 is a 25 A four-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.

What is the rated current of the EPX-XT2S-TM0254?

The EPX-XT2S-TM0254 has a 25 A rated current and uses the ABB SACE Tmax XT2S 160 A frame platform. The 160 A designation identifies the frame current class rather than the rated current of this particular circuit breaker.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2S-TM0254 has a specified 50 kA short-circuit breaking capacity. The applicable rated operating voltage and manufacturer short-circuit performance conditions must be checked against the prospective fault current at the installation location.

What does thermal-magnetic protection mean?

Thermal-magnetic protection combines a thermal element for overload protection with a magnetic element for short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption when fault current reaches its trip threshold.

Does the EPX-XT2S-TM0254 use a TMA or TMD trip unit?

The ABB Protecta Power ordering description identifies the EPX-XT2S-TM0254 within its TMA thermal-magnetic range. However, ABB's corresponding XT2S 25 A four-pole breaker reference, 1SDA067573R1, is identified as a TMD thermal-magnetic configuration. The underlying breaker designation should be used when checking its exact protection characteristics and settings.

What does the four-pole configuration mean?

The four-pole configuration provides coordinated switching of three phase conductors and a neutral conductor. It is suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. Neutral protection characteristics should be confirmed for the selected breaker configuration.

What is the difference between ABB XT2N and XT2S circuit breakers?

XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding ABB Protecta Power XT2N devices are specified at 36 kA, while XT2S versions are specified at 50 kA. Selection should be based on the prospective fault current and applicable operating voltage.

Can the EPX-XT2S-TM0254 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2S-TM0254 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection requirements should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, dependable thermal-magnetic operation and substantial short-circuit interruption capability for modern low-voltage power systems.