ABB EPX-XT2S-TM0254 is a 25 A four-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, using ABB SACE Tmax XT2S thermal-magnetic protection for low-voltage three-phase electrical distribution systems.
£575.92
The ABB EPX-XT2S-TM0254 is a compact, high-performance 25 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S 160 A frame platform, combining robust construction, thermal-magnetic protection and substantial short-circuit interruption capability.
Featuring a thermal-magnetic trip unit, the EPX-XT2S-TM0254 provides overload protection and magnetic short-circuit protection for electrical distribution circuits. ABB identifies the corresponding XT2S 25 A four-pole breaker configuration as using TMD thermal-magnetic protection, while the Protecta Power ordering description classifies the device within its TMA range. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption during short-circuit conditions.
With a rated current of 25 A, a four-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for appropriately designed three-phase distribution circuits incorporating a neutral conductor. Its compact 120 mm-wide XT2S four-pole format supports integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, switchboard manufacturers and maintenance engineers.
The ABB EPX-XT2S-TM0254 uses thermal and magnetic trip mechanisms to protect electrical circuits against abnormal current conditions. During sustained overloads, the thermal protection element responds to excessive current according to its time-current characteristics, helping reduce the risk of overheating in cables, terminals and connected equipment. During short-circuit conditions, the magnetic protection element responds rapidly when fault current reaches the applicable trip threshold, initiating circuit interruption to reduce the consequences of electrical faults.
The corresponding ABB XT2S 25 A four-pole breaker uses TMD thermal-magnetic protection, which provides conventional overload and short-circuit protection characteristics. The distinction between the Protecta Power TMA ordering classification and the underlying TMD breaker designation is important when reviewing technical documentation or selecting replacement components. Protection settings and trip characteristics should be confirmed against the markings and manufacturer documentation for the supplied device rather than assuming that every TMA-labelled Protecta Power breaker has identical adjustment capabilities.
The ABB SACE Tmax XT2S platform combines compact construction with a specified 50 kA short-circuit breaking capacity, making this device suitable for appropriately engineered electrical distribution systems requiring substantial fault interruption capability. Its four-pole design supports coordinated switching of three phase conductors and a neutral conductor. Electrical engineers should verify the applicable operating voltage, prospective short-circuit current, neutral protection requirements and coordination with upstream and downstream protective devices before installation.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT2 |
| Product model | EPX-XT2S-TM0254 |
| ABB order code | 1SDX255109R1 |
| Corresponding ABB circuit breaker reference | 1SDA067573R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT2S 160 |
| Frame current class | 160 A |
| Rated current (In) | 25 A |
| Number of poles | 4 |
| Specified short-circuit breaking capacity | 50 kA |
| Trip unit technology | Thermal-magnetic |
| Protecta Power catalogue designation | TMA |
| Corresponding ABB breaker trip designation | TMD |
| Overload protection | Thermal trip mechanism |
| Short-circuit protection | Magnetic trip mechanism |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase with neutral |
| Nominal device width | 120 mm |
| Operating mechanism | Manual toggle operation |
| Primary function | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT2S-TM0254 is a 25 A four-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT2S-TM0254 has a 25 A rated current and uses the ABB SACE Tmax XT2S 160 A frame platform. The 160 A designation identifies the frame current class rather than the rated current of this particular circuit breaker.
The EPX-XT2S-TM0254 has a specified 50 kA short-circuit breaking capacity. The applicable rated operating voltage and manufacturer short-circuit performance conditions must be checked against the prospective fault current at the installation location.
Thermal-magnetic protection combines a thermal element for overload protection with a magnetic element for short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption when fault current reaches its trip threshold.
The ABB Protecta Power ordering description identifies the EPX-XT2S-TM0254 within its TMA thermal-magnetic range. However, ABB's corresponding XT2S 25 A four-pole breaker reference, 1SDA067573R1, is identified as a TMD thermal-magnetic configuration. The underlying breaker designation should be used when checking its exact protection characteristics and settings.
The four-pole configuration provides coordinated switching of three phase conductors and a neutral conductor. It is suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. Neutral protection characteristics should be confirmed for the selected breaker configuration.
XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding ABB Protecta Power XT2N devices are specified at 36 kA, while XT2S versions are specified at 50 kA. Selection should be based on the prospective fault current and applicable operating voltage.
Yes. The EPX-XT2S-TM0254 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection requirements should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, dependable thermal-magnetic operation and substantial short-circuit interruption capability for modern low-voltage power systems.