ABB EPX-XT2S-TM0204 is a 20 A four-pole moulded case circuit breaker from the Protecta Power Devices range, featuring an XT2S frame, 50 kA short-circuit breaking capacity and TMA thermal-magnetic adjustable protection for low-voltage electrical distribution systems.
£575.92
The ABB EPX-XT2S-TM0204 is a compact and dependable 20 A 4-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices product group, this circuit breaker features an XT2S frame and thermal-magnetic adjustable (TMA) trip unit, making it suitable for commercial buildings, industrial installations and electrical distribution assemblies.
The EPX-XT2S-TM0204 combines thermal overload protection with magnetic short-circuit protection to help safeguard electrical circuits, cables and connected equipment against excessive current and electrical faults. Its four-pole construction enables switching of three-phase circuits incorporating a neutral conductor, making it particularly suitable for power distribution systems requiring four-pole circuit isolation and protection.
With a 20 A rated current, 50 kA short-circuit breaking capacity and 4-pole configuration, the ABB EPX-XT2S-TM0204 provides a robust protection solution for appropriately designed low-voltage installations. Its compact XT2S construction supports efficient integration into compatible ABB Protecta Power distribution boards, switchgear assemblies and electrical control panels.
Moulded case circuit breakers such as the ABB EPX-XT2S-TM0204 are essential components in modern electrical distribution installations. They automatically interrupt electrical circuits when overload or short-circuit conditions occur, helping reduce the risk of damage to electrical cables, distribution equipment and connected loads while supporting reliable electrical operation.
The TMA thermal-magnetic trip unit combines two complementary protection functions. The thermal element responds to sustained overload currents, while the magnetic element operates during significant short-circuit conditions. This combination provides dependable overcurrent protection and helps minimise the effects of electrical faults on connected equipment.
The 20 A four-pole XT2S configuration is particularly suitable for three-phase electrical distribution systems incorporating a neutral conductor. Its compact construction supports efficient use of available space within electrical panels, while the specified 50 kA breaking capacity provides substantial short-circuit interruption capability under the applicable rated conditions.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0204 is designed for integration into compatible low-voltage distribution equipment. Electrical engineers and installers can use this circuit breaker in appropriately specified commercial and industrial installations where dependable circuit protection, isolation and maintainability are important.
Correct selection and installation should account for the electrical system voltage, prospective short-circuit current, conductor sizing, protective device coordination and applicable wiring regulations. The suitability of the circuit breaker for a particular installation must be assessed against the relevant electrical design requirements.
The ABB EPX-XT2S-TM0204 is a moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, switchgear assemblies and three-phase electrical installations.
The circuit breaker has a 20 A rated current, making it suitable for appropriately designed electrical distribution circuits requiring a 20 A MCCB with thermal-magnetic protection.
The ABB EPX-XT2S-TM0204 has a specified 50 kA short-circuit breaking capacity. This represents its short-circuit interruption capability under the applicable rated conditions. The electrical system voltage and prospective fault current must be considered when confirming suitability for an installation.
This circuit breaker incorporates a TMA thermal-magnetic adjustable trip unit. The thermal element provides overload protection, while the magnetic element responds to short-circuit conditions, helping protect electrical circuits and connected equipment against excessive current.
The ABB EPX-XT2S-TM0204 is a 4-pole MCCB, suitable for low-voltage distribution applications requiring four-pole switching, including three-phase electrical circuits incorporating a neutral conductor.
ABB Protecta Power Devices provide dependable circuit protection solutions for modern commercial and industrial electrical distribution systems. The ABB EPX-XT2S-TM0204 combines a compact XT2S frame, 20 A rated current, four-pole construction, 50 kA breaking capacity and TMA thermal-magnetic protection to support reliable operation in low-voltage electrical installations.