ABB EPX-XT2S-TM0164 is a 16 A four-pole Tmax XT2S moulded case circuit breaker with 50 kA breaking capacity and TMA thermal-magnetic protection, designed for compatible Protecta Power low-voltage electrical distribution systems.
£575.92
The ABB EPX-XT2S-TM0164 is a compact and reliable 16 A four-pole moulded case circuit breaker (MCCB) designed to provide overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a specified 50 kA breaking capacity and thermal-magnetic protection, this circuit breaker belongs to the ABB Protecta Power Devices range and uses the proven ABB Tmax XT2S platform.
Designed for professional electrical distribution applications, the EPX-XT2S-TM0164 combines dependable switching performance with thermal-magnetic circuit protection. Its manufacturer-specified TMA trip arrangement provides protection against sustained overload currents and high-current short-circuit faults, helping safeguard electrical cables, connected equipment and distribution circuits.
With a rated current of 16 A, a four-pole (4P) configuration and a specified 50 kA short-circuit breaking capacity, the EPX-XT2S-TM0164 is suitable for appropriately designed three-phase electrical distribution circuits requiring four-pole operation. Identified by ABB order code 1SDX255107R1, this MCCB provides a coordinated circuit protection solution for compatible ABB Protecta Power panelboard installations.
Moulded case circuit breakers are essential protective devices in electrical distribution systems. They automatically interrupt electrical current when overload or short-circuit conditions exceed the protective characteristics of the installed device. Thermal-magnetic circuit breakers achieve this using two complementary protection mechanisms: a thermal element that responds to sustained overcurrent and a magnetic element that responds rapidly to high short-circuit currents.
The ABB EPX-XT2S-TM0164 combines a 16 A rated current with TMA thermal-magnetic protection. Its thermal protection function helps prevent prolonged overload conditions from damaging conductors and connected equipment, while its magnetic protection function provides rapid fault interruption during sufficiently high short-circuit currents.
The ABB Tmax XT2S circuit breaker platform is developed for dependable switching and protection in low-voltage distribution systems. Its compact moulded case construction, four-pole operating mechanism and short-circuit interruption capabilities make it suitable for electrical installations where reliable circuit protection and efficient use of panel space are important.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0164 is intended for integration into compatible Protecta Power distribution assemblies. Correct installation requires verification of the prospective short-circuit current, operating voltage, conductor sizing, neutral arrangement and coordination with other protective devices. The specified 50 kA breaking capacity must be assessed under the applicable manufacturer rating conditions.
The ABB EPX-XT2S-TM0164 is a 16 A four-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution systems.
The EPX-XT2S-TM0164 has a rated current of 16 A and uses the ABB Tmax XT2S circuit breaker platform.
The EPX-XT2S-TM0164 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity must be considered in relation to the operating voltage and the manufacturer's electrical rating conditions.
TMA identifies a thermal-magnetic trip arrangement combining thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption during high-current faults.
The EPX-XT2S-TM0164 is a four-pole (4P) MCCB, suitable for appropriately designed electrical distribution systems requiring simultaneous switching of three phase conductors and a neutral conductor.
This model uses the ABB Tmax XT2S frame and belongs to the ABB Protecta Power Devices range for compatible low-voltage electrical distribution assemblies.
Yes. The EPX-XT2S-TM0164 is specified within the ABB Protecta Power Devices range for compatible distribution assemblies. The appropriate mounting arrangement, electrical connections and enclosure configuration must be selected according to ABB installation documentation.
The ABB order code is 1SDX255107R1, identifying the EPX-XT2S-TM0164 16 A, four-pole, 50 kA MCCB with TMA thermal-magnetic protection.
ABB Tmax XT moulded case circuit breakers and Protecta Power distribution components provide electrical engineers, contractors and professional panel builders with coordinated solutions for dependable low-voltage circuit protection. The EPX-XT2S-TM0164 combines a 16 A rating, four-pole construction, 50 kA breaking capacity and TMA thermal-magnetic protection to support reliable electrical distribution in commercial and industrial installations.