ABB EPX-XT1S-TM1254 is a 125 A four-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA short-circuit breaking capacity, a 100% rated neutral pole and TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.
£748.29
The ABB EPX-XT1S-TM1254 is a high-performance 125 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT1S160 platform, offering reliable protection for commercial buildings, industrial facilities and electrical infrastructure.
Equipped with a thermal-magnetic trip unit, the EPX-XT1S-TM1254 combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption during short-circuit faults. These complementary protection functions help safeguard electrical cables, switchgear and connected equipment against potentially damaging electrical conditions.
With a 125 A rated current, four-pole construction and 50 kA short-circuit breaking capacity, this MCCB is suitable for three-phase electrical distribution systems requiring four-pole switching and substantial fault-interruption capability. Its 100% rated neutral pole makes it particularly suitable for appropriately designed three-phase and neutral distribution arrangements. The compact ABB Tmax XT1S160 frame supports integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.
Moulded case circuit breakers such as the ABB EPX-XT1S-TM1254 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Its TMA thermal-magnetic trip unit combines a thermal protection element, which responds to sustained excessive current, with a magnetic element that provides rapid interruption during short-circuit faults. These complementary protection functions help reduce the risk of damage to electrical cables, distribution equipment and connected circuits.
The ABB SACE Tmax XT1 circuit breaker family is designed for dependable protection in compact low-voltage electrical distribution assemblies. The EPX-XT1S-TM1254 is particularly suitable for installations requiring 125 A four-pole circuit protection and a 50 kA short-circuit breaking rating. Its 100% rated neutral pole supports applications where a fully rated neutral conductor is required, subject to the installation's earthing arrangement and neutral protection requirements. Circuit breaker selection should consider operating voltage, prospective fault current, conductor characteristics, load requirements and protective device coordination. Where the MCCB supplies a motor circuit, dedicated motor overload protection may also be necessary.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT |
| Frame designation | XT1S160 |
| ABB order code | 1SDX255105R1 |
| Corresponding ABB circuit breaker reference | 1SDA067445R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 125 A |
| Number of poles | 4 |
| Short-circuit breaking capacity | 50 kA |
| Trip unit | TMA |
| Trip unit technology | Thermal-magnetic |
| Overload protection | Thermal trip element |
| Short-circuit protection | Magnetic trip element |
| Protection functions | Overload and short-circuit protection |
| Neutral pole rating | 100% |
| Frame family | XT1S160 |
| Maximum frame rating | 160 A |
| Switching configuration | Four-pole |
| Operating mechanism | Manual operation |
| Application | Low-voltage three-phase electrical distribution |
| Installation | Compatible electrical distribution boards and switchgear assemblies |
| Circuit breaker standard | IEC/EN 60947-2 |
The ABB EPX-XT1S-TM1254 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial electrical installations requiring four-pole switching.
The circuit breaker has a 125 A rated current and uses the ABB Tmax XT1S160 frame, which has a maximum frame rating of 160 A. The rated current of this specific MCCB is 125 A, not the maximum rating of its frame.
The EPX-XT1S-TM1254 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation's operating voltage must be verified against ABB technical documentation and the prospective fault current before selection.
The TMA thermal-magnetic trip unit combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid tripping during short-circuit faults, helping safeguard cables and connected electrical equipment.
The four-pole construction allows four conductors to be switched together, making the MCCB suitable for three-phase distribution arrangements where neutral switching is required. Its 100% rated neutral pole supports installations requiring a fully rated neutral conductor. The neutral switching and protection arrangements must be checked against the installation's earthing system and electrical design requirements.
ABB SACE Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT1S-TM1254 combines a 125 A rating, four-pole construction, 100% rated neutral, 50 kA breaking capacity and thermal-magnetic protection in a compact solution for commercial, industrial and building services electrical installations.