1SDX255102R1 ABB EPX-XT1S-TM0504 50A 4-Pole 50kA TMA MCCB

1SDX255102R1 ABB EPX-XT1S-TM0504 50A 4-Pole 50kA TMA MCCB

ABB EPX-XT1S-TM0504 is a 50 A four-pole moulded case circuit breaker with 50 kA breaking capacity and thermal-magnetic protection, designed for overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX255102R1Alt SKU: EPX-XT1S-TM0504MPN: 1SDX255102R1
Price
List Price £508.39 ex VAT
Your Price (ex VAT)
£508.39
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £508.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£508.39

Why Choose the ABB EPX-XT1S-TM0504 50A 4-Pole MCCB?

The ABB EPX-XT1S-TM0504 is a high-performance 50 A, 4-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and a thermal-magnetic (TMA) trip unit, this circuit breaker is suitable for commercial, industrial and building services electrical installations requiring reliable four-pole circuit protection.

As part of the ABB Protecta Power Devices range, the EPX-XT1S-TM0504 incorporates proven ABB SACE Tmax XT1S160 circuit breaker technology. Its thermal-magnetic protection system combines overload protection with rapid magnetic short-circuit tripping, helping protect electrical cables, distribution equipment and connected installations against damaging fault conditions.

With a 50 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT1S-TM0504 is designed for three-phase electrical distribution applications requiring neutral conductor switching. Its compact XT1S frame and 110 mm four-pole device width support efficient integration into ABB Protecta Power distribution boards and compatible low-voltage switchgear assemblies.

Key Advantages

  • 50 A rated current suitable for low-voltage electrical distribution circuits.
  • 50 kA breaking capacity provides protection against high prospective short-circuit currents at the applicable rated voltage.
  • Four-pole construction enables switching of three phase conductors and the neutral conductor.
  • Thermal-magnetic trip unit provides dependable overload and short-circuit protection.
  • ABB SACE Tmax XT1S160 technology combines reliable circuit protection with compact construction.
  • 110 mm device width supports efficient use of space in distribution assemblies.
  • Mechanical switching and automatic fault tripping help improve electrical system reliability.
  • Suitable for integration into ABB Protecta Power distribution systems and compatible low-voltage switchgear.

Key Features

  • ABB Protecta Power Devices moulded case circuit breaker.
  • SACE Tmax XT1S160 circuit breaker platform.
  • 50 A rated current for electrical distribution protection.
  • 50 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • Four-pole configuration for three-phase and neutral electrical distribution.
  • Thermal-magnetic (TMA) protection for overload and short-circuit fault conditions.
  • Compact moulded case construction for electrical distribution assemblies.
  • 110 mm four-pole width for compatible Protecta Power installations.
  • Manual mechanical switching with automatic protective tripping.
  • Designed for use in commercial and industrial low-voltage electrical systems.
  • Based on ABB circuit breaker technology designed in accordance with IEC 60947-2.

Reliable Four-Pole Thermal-Magnetic Circuit Protection

The ABB EPX-XT1S-TM0504 provides essential electrical protection through its thermal-magnetic trip mechanism. The thermal element responds to sustained overload conditions, while the magnetic element enables rapid interruption during high-current short-circuit faults. These protection functions help reduce the risk of damage to electrical conductors, distribution equipment and connected installations.

The four-pole XT1S configuration supports simultaneous switching of three phase conductors and the neutral conductor, making it suitable for distribution systems requiring four-pole isolation. Combined with its 50 kA breaking capacity, compact construction and proven ABB Tmax XT technology, the EPX-XT1S-TM0504 provides dependable circuit protection for modern commercial and industrial electrical distribution systems.

Typical Applications

  • Commercial and industrial low-voltage distribution boards.
  • ABB Protecta Power electrical distribution assemblies.
  • Three-phase and neutral electrical distribution circuits.
  • Industrial machinery and equipment supply circuits.
  • Electrical switchboards and control panels.
  • Building services and infrastructure power distribution.
  • Manufacturing facilities and industrial electrical installations.
  • Sub-distribution circuits requiring four-pole thermal-magnetic protection.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT1S
ABB order code 1SDX255102R1
Product type Moulded case circuit breaker (MCCB)
Rated current 50 A
Number of poles 4
Rated ultimate short-circuit breaking capacity 50 kA at 415 V AC
Trip unit type TMA – thermal-magnetic
Protection functions Thermal overload and magnetic short-circuit protection
Frame designation XT1S160
Frame current rating 160 A
Device width 110 mm
Electrical system Three-phase with neutral
Operating mechanism Mechanical toggle operation
Application Low-voltage electrical distribution
Applicable standard IEC 60947-2
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT1S-TM0504 used for?

The ABB EPX-XT1S-TM0504 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT1S-TM0504?

The circuit breaker has a 50 A rated current and belongs to the ABB SACE Tmax XT1S160 frame family.

What is the breaking capacity of this ABB MCCB?

The EPX-XT1S-TM0504 has a 50 kA rated ultimate short-circuit breaking capacity at 415 V AC, making it suitable for appropriately designed low-voltage electrical distribution systems.

What does TMA mean on the ABB EPX-XT1S-TM0504?

TMA identifies a thermal-magnetic trip unit that provides overload protection through a thermal element and short-circuit protection through a magnetic element. The applicable adjustment characteristics depend on the specific trip unit configuration.

What is the advantage of the four-pole configuration?

The four-pole design allows switching of all three phase conductors together with the neutral conductor, making the breaker suitable for electrical distribution systems requiring four-pole switching and isolation.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT moulded case circuit breakers are engineered to provide reliable electrical protection in commercial and industrial low-voltage distribution systems. The EPX-XT1S-TM0504 combines a 50 A rated current, four-pole construction, 50 kA breaking capacity and thermal-magnetic protection in a compact XT1S160 frame for dependable electrical distribution applications.