1SDX255098R1 ABB EPX-XT1S-TM0164 16A 4-Pole 50kA MCCB TMA

1SDX255098R1 ABB EPX-XT1S-TM0164 16A 4-Pole 50kA MCCB TMA

ABB EPX-XT1S-TM0164 is a 16 A four-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection. Part of the ABB Protecta Power Devices range, it is designed for commercial and industrial low-voltage electrical distribution systems requiring four-pole switching.

SKU: 1SDX255098R1Alt SKU: EPX-XT1S-TM0164MPN: 1SDX255098R1
Price
List Price £508.39 ex VAT
Your Price (ex VAT)
£508.39
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £508.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£508.39

Why Choose the ABB EPX-XT1S-TM0164 16A 4-Pole 50kA MCCB?

The ABB EPX-XT1S-TM0164 is a compact, high-performance 16 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 50 kA short-circuit breaking capacity with TMA thermal-magnetic protection, offering a practical solution for three-phase and neutral circuits requiring a relatively low current rating and substantial fault-interruption capability.

Built around the established ABB SACE Tmax XT1S platform, the EPX-XT1S-TM0164 incorporates a thermal-magnetic protection arrangement that responds to sustained overloads and high-current short circuits. The TMA trip designation identifies a thermal-magnetic protection system, combining inverse-time thermal overload protection with rapid magnetic short-circuit operation.

Its four-pole (4P) configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design. This makes the ABB EPX-XT1S-TM0164 suitable for appropriately designed three-phase distribution circuits in commercial buildings, industrial facilities and electrical distribution assemblies.

With a 16 A rated current, 50 kA breaking capacity and compact 110 mm four-pole width, the ABB EPX-XT1S-TM0164 offers a space-efficient circuit protection solution for compatible ABB Protecta Power panelboards. The product is identified by ABB order code 1SDX255098R1.

Key Advantages

  • 16 A rated current for appropriately designed low-current electrical distribution circuits.
  • Four-pole (4P) configuration for coordinated switching of three phase conductors and a neutral conductor.
  • 50 kA short-circuit breaking capacity for installations requiring substantial fault-interruption performance.
  • TMA thermal-magnetic protection combines overload and short-circuit protection within one MCCB.
  • Thermal overload protection helps safeguard conductors and connected equipment against sustained excessive current.
  • Magnetic short-circuit protection provides rapid operation during significant fault conditions.
  • Four-pole switching supports distribution arrangements requiring neutral disconnection.
  • Compact 110 mm width helps optimise installation space within compatible distribution equipment.
  • ABB SACE Tmax XT1S construction combines robust mechanical design with established circuit protection technology.
  • Mechanical thermal-magnetic operation provides straightforward protection without requiring an electronic trip unit.
  • High breaking capacity relative to rated current makes the device suitable for consideration in distribution systems with significant prospective fault currents.
  • Compatible ABB Protecta Power installation supports integration into appropriately configured panelboards.
  • ABB product identification simplifies specification, procurement and maintenance documentation.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT1S-TM0164 product designation.
  • 16 A rated current for low-voltage circuit protection.
  • Four-pole (4P) construction for three-phase and neutral electrical distribution.
  • 50 kA specified short-circuit breaking capacity.
  • TMA thermal-magnetic trip designation for overload and short-circuit protection.
  • Thermal overload response for sustained overcurrent conditions.
  • Magnetic short-circuit response for rapid operation during high-current faults.
  • Inverse-time thermal characteristic to help protect conductors against excessive heating.
  • Four-pole switching arrangement for circuits requiring coordinated phase and neutral disconnection.
  • ABB SACE Tmax XT1S platform with S breaking-capacity classification.
  • XT1 frame family for compact low-voltage circuit protection.
  • 110 mm four-pole device width for efficient distribution assembly installation.
  • Manual switching mechanism with automatic thermal-magnetic protective tripping.
  • Robust moulded case construction suitable for professional electrical distribution environments.
  • Three-phase and neutral circuit protection for appropriately designed installations.
  • Compatible ABB Protecta Power installation using the correct mounting and connection components.
  • ABB order code 1SDX255098R1 for accurate product identification.

Reliable Four-Pole Thermal-Magnetic Protection for Electrical Distribution

The ABB EPX-XT1S-TM0164 provides dependable protection for low-voltage electrical distribution circuits where a compact four-pole MCCB is required. Its thermal-magnetic protection system responds to sustained overload conditions and high-current short-circuit faults, helping safeguard electrical conductors, connected equipment and distribution infrastructure against excessive current.

The thermal overload protection responds when current exceeds the applicable protective threshold for a sufficient period. Its inverse-time characteristic means that higher overload currents generally produce faster tripping. This helps limit excessive conductor heating while accommodating normal operating conditions within the electrical circuit's design parameters.

The magnetic short-circuit protection responds rapidly when fault current reaches the magnetic operating threshold. This is particularly important during short circuits, where large fault currents can create substantial thermal and mechanical stresses within an electrical installation. Rapid circuit interruption helps reduce the duration of these potentially damaging conditions.

The TMA thermal-magnetic configuration offers a practical alternative to electronic circuit protection where straightforward operation is preferred. Thermal-magnetic MCCBs combine overload and short-circuit protection within a single switching device. The exact available adjustment settings and protection characteristics should be confirmed from the ABB technical documentation for the supplied breaker.

The four-pole construction is an important feature of the EPX-XT1S-TM0164. Unlike a three-pole MCCB, a four-pole device can provide coordinated switching of the neutral conductor alongside the three phase conductors. This may be necessary for certain electrical distribution arrangements, isolation requirements and installation designs. However, the suitability of neutral switching depends on the earthing system, applicable electrical standards and the specific circuit configuration.

It is also important to distinguish between neutral switching and neutral overcurrent protection. A four-pole circuit breaker provides an additional switched pole, but the protection characteristics of that pole depend on the specific device construction. Electrical designers should verify the manufacturer's neutral pole arrangements and applicable protection characteristics before specifying the MCCB for a particular installation.

The 50 kA short-circuit breaking capacity is particularly valuable where a relatively low-current outgoing circuit is supplied from a distribution system with substantial available fault current. Although the breaker has a 16 A rated current, the prospective short-circuit current at its installation point may be significantly higher. The selected breaker must therefore have adequate fault-interruption capability at the relevant operating voltage.

The ABB SACE Tmax XT1S platform provides a compact and robust foundation for this MCCB. Its 110 mm four-pole width supports efficient installation within compatible electrical distribution equipment, while the XT1S construction offers established thermal-magnetic circuit protection for commercial and industrial applications.

As part of the ABB Protecta Power range, the EPX-XT1S-TM0164 is intended for installation in compatible panelboards and distribution assemblies using the correct mounting and connection components. Before commissioning, electrical designers and installers should verify the prospective fault current, operating voltage, conductor ratings, protection characteristics, neutral requirements and coordination with other protective devices.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible distribution assemblies.
  • Three-phase outgoing circuits requiring four-pole switching.
  • Industrial switchboards and sub-distribution panels.
  • Manufacturing and production facilities.
  • Commercial offices and business premises.
  • Retail buildings and hospitality facilities.
  • Warehouses and logistics centres.
  • Building services and mechanical plant electrical distribution.
  • Lower-current three-phase and neutral feeder circuits.
  • Distribution circuits requiring thermal overload and magnetic short-circuit protection.
  • Installations requiring a 50 kA short-circuit breaking capacity.
  • Electrical distribution arrangements requiring appropriately designed neutral switching.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Product range Protecta Power
Circuit breaker platform ABB SACE Tmax XT1S
ABB order code 1SDX255098R1
Corresponding ABB XT1S breaker reference 1SDA080845R1
Product type Moulded case circuit breaker (MCCB)
Rated current 16 A
Number of poles 4
Electrical configuration Three-phase and neutral
Short-circuit breaking capacity 50 kA
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection principle Thermal inverse-time operation
Short-circuit protection principle Magnetic operation
Frame family XT1
Frame designation XT1S
Frame current class 160 A
Breaking-capacity classification S
Device width 110 mm
Operating mechanism Manual switching with automatic thermal-magnetic tripping
Applicable circuit breaker standard IEC 60947-2
Application category Low-voltage electrical power distribution
Mounting application Compatible electrical distribution assemblies
Typical installation ABB Protecta Power panelboards and compatible distribution equipment
Neutral switching Four-pole configuration; neutral protection characteristics must be confirmed against the applicable ABB documentation
Installation requirements Verify operating voltage, prospective fault current, conductor ratings, earthing arrangements and assembly compatibility before installation

Frequently Asked Questions

What is the ABB EPX-XT1S-TM0164 used for?

The ABB EPX-XT1S-TM0164 is a four-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT1S-TM0164?

The circuit breaker has a rated current of 16 A. It is intended for appropriately designed three-phase and neutral electrical circuits requiring thermal-magnetic overload and short-circuit protection.

What is the breaking capacity of this MCCB?

The ABB EPX-XT1S-TM0164 has a specified 50 kA short-circuit breaking capacity. Its suitability must be assessed against the installation's prospective fault current, operating voltage and applicable electrical protection requirements.

What does TMA mean on the ABB XT1S circuit breaker?

TMA is a thermal-magnetic trip designation. Thermal-magnetic protection combines a thermal element that responds to sustained overloads with a magnetic element that operates during high-current short circuits. The exact adjustment characteristics should be verified against the ABB technical documentation for the supplied device.

What is the advantage of the four-pole configuration?

The four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design. This can be useful in three-phase and neutral distribution systems, subject to the installation's earthing arrangements, neutral protection requirements and applicable electrical standards.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection engineering with practical low-voltage distribution solutions. The EPX-XT1S-TM0164 offers a compact 16 A, four-pole XT1S MCCB configuration with TMA thermal-magnetic protection and a 50 kA breaking capacity, supporting dependable circuit protection in appropriately designed commercial and industrial electrical installations.