Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT5S-TM3203 is a 320 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution.
£1,416.50
The ABB EPX-XT5S-TM3203 is a 320 A three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution systems against overloads and short circuits. Featuring a 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection, this circuit breaker provides dependable protection for commercial, industrial and infrastructure applications.
Part of the ABB Protecta Power Devices range, the EPX-XT5S-TM3203 belongs to the ABB SACE Tmax XT5S circuit breaker family. Its thermal-magnetic protection release combines thermal overload detection with magnetic short-circuit protection, helping safeguard conductors, electrical equipment and distribution circuits against excessive currents.
With a 320 A rated current, three-pole configuration and 50 kA breaking capacity, the EPX-XT5S-TM3203 is suitable for appropriately designed three-phase electrical distribution systems. Its combination of substantial current-carrying capability and thermal-magnetic protection makes it a practical choice for distribution feeders, industrial switchboards and compatible ABB Protecta Power assemblies.
The ABB EPX-XT5S-TM3203 incorporates TMA thermal-magnetic protection to respond to overload and short-circuit conditions. The thermal protection element operates in response to sustained excessive currents, helping reduce the risk of conductor overheating and equipment damage. The magnetic protection element provides rapid operation when the fault current reaches the applicable short-circuit tripping threshold. Protection settings should be selected in accordance with ABB's technical instructions and the requirements of the electrical installation.
The ABB SACE Tmax XT5S platform provides a robust foundation for higher-current low-voltage circuit protection. Combining a 320 A rated current, three-pole construction and 50 kA breaking capacity, the EPX-XT5S-TM3203 is suitable for distribution feeders and industrial electrical systems requiring substantial load capacity and dependable fault interruption. Correct selection must consider the operating voltage, prospective short-circuit current, conductor ratings and coordination with other protective devices.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker family | SACE Tmax XT |
| Series | XT5S |
| ABB order code | 1SDX254981R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 320 A |
| Number of poles | 3 |
| Short-circuit breaking capacity | 50 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Frame family | XT5 |
| Breaking capacity class | S |
| Operating mechanism | Manual switching with automatic protective tripping |
| Application | Low-voltage three-phase electrical distribution |
| Circuit breaker standard | IEC 60947-2 |
The ABB EPX-XT5S-TM3203 is a 320 A three-pole MCCB used to protect low-voltage electrical distribution circuits against overloads and short circuits.
The EPX-XT5S-TM3203 has a rated current of 320 A, making it suitable for appropriately designed higher-capacity electrical distribution circuits.
The EPX-XT5S-TM3203 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation voltage must be checked against the prospective fault current.
TMA identifies a thermal-magnetic protection release with adjustable protection functionality. Thermal protection responds to overloads, while magnetic protection responds to short-circuit faults.
The TMA designation indicates adjustable thermal-magnetic protection functionality. The available settings and adjustment ranges should be confirmed against ABB's documentation for the supplied release.
Yes. The EPX-XT5S-TM3203 has a three-pole (3P) configuration suitable for three-phase electrical distribution applications.
The EPX-XT5S-TM3203 belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT5S circuit breaker platform.
The S designation identifies a breaking capacity class within the ABB SACE Tmax XT5 family. This model has a specified breaking capacity of 50 kA.
Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its electrical ratings, protection characteristics and installation requirements match the application.
The ABB order code is 1SDX254981R1, identifying this model within the ABB Protecta Power Devices range.
ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, contractors and industrial maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT5S-TM3203 combines a 320 A rated current, three-pole configuration and 50 kA breaking capacity with TMA thermal-magnetic protection, making it a practical solution for commercial and industrial electrical distribution.