ABB EPX-XT4S-TM2503 is a 250 A three-pole Tmax XT4S moulded case circuit breaker with 50 kA breaking capacity and adjustable TMA thermal-magnetic protection, designed for compatible Protecta Power low-voltage electrical distribution systems.
£1,106.15
The ABB EPX-XT4S-TM2503 is a high-performance 250 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection, this circuit breaker forms part of the ABB Protecta Power Devices range and incorporates the proven ABB Tmax XT4S circuit breaker platform.
Designed for professional electrical distribution applications, the EPX-XT4S-TM2503 combines reliable switching performance with adjustable thermal-magnetic protection technology. Its TMA trip unit provides thermal overload protection and magnetic short-circuit protection, helping safeguard cables, electrical equipment and distribution circuits against excessive current and fault conditions.
With a rated current of 250 A, a three-pole configuration and a specified 50 kA breaking capacity, the EPX-XT4S-TM2503 is suitable for compatible Protecta Power distribution assemblies serving commercial buildings, industrial facilities and electrical infrastructure. Identified by ABB order code 1SDX254975R1, this MCCB provides a coordinated solution for three-phase outgoing feeder protection and professional low-voltage switchboard construction.
Moulded case circuit breakers protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. Thermal-magnetic MCCBs combine two complementary protective mechanisms: a thermal element that responds to sustained overload currents and a magnetic element that operates rapidly when high short-circuit currents are detected.
The ABB EPX-XT4S-TM2503 incorporates TMA thermal-magnetic protection, providing adjustable overload and short-circuit protection within a compact three-pole circuit breaker. The thermal protection function helps prevent prolonged overcurrent conditions from damaging cables and connected equipment, while the magnetic protection function provides rapid interruption of severe electrical faults.
The ABB Tmax XT4S platform is developed for dependable switching and circuit protection in low-voltage distribution systems. Its combination of robust moulded case construction, adjustable thermal-magnetic protection and high short-circuit interruption performance makes it suitable for industrial and commercial electrical distribution applications.
As part of the ABB Protecta Power Devices range, the EPX-XT4S-TM2503 is intended for integration into compatible Protecta Power panelboard configurations. Correct installation requires verification of the prospective short-circuit current, appropriate conductor sizing, protection settings and coordination with upstream and downstream protective devices. The specified 50 kA breaking capacity must be assessed at the relevant operating voltage and in accordance with the manufacturer's rating conditions.
The ABB EPX-XT4S-TM2503 is a 250 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection for three-phase electrical distribution circuits within compatible ABB Protecta Power assemblies.
The EPX-XT4S-TM2503 has a rated current of 250 A and uses the ABB Tmax XT4S circuit breaker platform.
The circuit breaker has a specified 50 kA short-circuit breaking capacity. The XT4S platform provides this breaking capacity at 415 V AC, subject to the applicable manufacturer rating conditions.
TMA refers to a thermal-magnetic trip unit with adjustable thermal overload and magnetic short-circuit protection. The thermal element responds to sustained overload conditions, while the magnetic element provides rapid tripping during high-current short-circuit faults.
Yes. The XT4S 250 TMA platform supports adjustable thermal and magnetic protection. The corresponding 250 A TMA configuration provides a thermal setting range of 175–250 A and a magnetic setting range of 1,250–2,500 A. Settings must be selected according to the circuit design and applicable ABB documentation.
The EPX-XT4S-TM2503 is a three-pole (3P) MCCB, designed for applications requiring simultaneous switching and protection of three phase conductors.
This model uses the ABB Tmax XT4S frame and forms part of the ABB Protecta Power Devices range for compatible low-voltage electrical distribution assemblies.
The ABB order code is 1SDX254975R1, identifying the EPX-XT4S-TM2503 250 A, three-pole, 50 kA MCCB with TMA thermal-magnetic protection.
ABB Tmax XT moulded case circuit breakers and Protecta Power distribution components provide electrical engineers, contractors and panel builders with coordinated solutions for dependable low-voltage circuit protection. The EPX-XT4S-TM2503 combines a 250 A rating, three-pole construction, 50 kA breaking capacity and adjustable TMA thermal-magnetic protection to support reliable operation in commercial and industrial power distribution systems.