1SDX254974R1 ABB EPX-XT4S-TM2003 200A 3P 50kA MCCB - TMA

1SDX254974R1 ABB EPX-XT4S-TM2003 200A 3P 50kA MCCB – TMA

ABB EPX-XT4S-TM2003 is a 200 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit. Part of the ABB Protecta Power Devices range, it provides adjustable thermal overload and instantaneous magnetic short-circuit protection for commercial and industrial low-voltage distribution systems.

SKU: 1SDX254974R1Alt SKU: EPX-XT4S-TM2003MPN: 1SDX254974R1
Price
List Price £874.70 ex VAT
Your Price (ex VAT)
£874.70
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £874.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£874.70

Why Choose the ABB EPX-XT4S-TM2003 200A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-TM2003 is a high-performance 200 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit, this circuit breaker forms part of the ABB Protecta Power Devices range and incorporates ABB's established SACE Tmax XT4S technology.

Engineered for installations requiring dependable circuit protection and substantial fault-current interruption capability, the EPX-XT4S-TM2003 combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection. Its thermal-magnetic operating principle provides a practical alternative to electronic trip releases, offering straightforward protection configuration without requiring a separate electronic trip-unit power supply.

With its 200 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT4S-TM2003 is suitable for appropriately designed three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX254974R1, this MCCB provides robust circuit protection for demanding low-voltage electrical installations.

Key Advantages

  • 200 A rated current provides dependable protection for appropriately designed three-phase electrical distribution circuits.
  • Three-pole (3P) configuration enables coordinated switching and protection of three phase conductors.
  • 50 kA short-circuit breaking capacity supports installations with substantial prospective fault currents.
  • TMA thermal-magnetic trip unit combines adjustable overload and short-circuit protection.
  • Adjustable thermal overload protection allows the protective threshold to be matched to circuit requirements.
  • Thermal adjustment range of 140–200 A provides flexibility for appropriately rated conductors and connected loads.
  • Adjustable magnetic short-circuit protection supports configuration of the instantaneous fault-current threshold.
  • Magnetic adjustment range of 1,000–2,000 A enables protection settings to be coordinated with the electrical installation.
  • Thermal-magnetic operating technology does not require a separate electronic trip-unit power supply.
  • ABB SACE Tmax XT4S construction combines robust switching performance with compact moulded case design.
  • S breaking-capacity classification offers a higher specified breaking capacity than corresponding XT4N 36 kA configurations.
  • 250 A XT4 frame platform provides the mechanical basis for the 200 A protective configuration.
  • Manual toggle-operated mechanism enables straightforward local switching and resetting.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial and industrial installations requiring adjustable thermal-magnetic overcurrent protection.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT4S moulded case circuit breaker platform.
  • 200 A rated current.
  • Three-pole (3P) configuration.
  • 50 kA short-circuit breaking capacity at the applicable rated operating conditions.
  • TMA adjustable thermal-magnetic protection release.
  • Adjustable thermal overload protection for sustained excessive current.
  • Thermal overload adjustment: 0.7–1.0 × In.
  • Thermal overload setting range: 140–200 A.
  • Adjustable instantaneous magnetic protection for short-circuit faults.
  • Magnetic protection adjustment: 5–10 × In.
  • Magnetic short-circuit setting range: 1,000–2,000 A.
  • Inverse-time thermal protection characteristic for overload conditions.
  • Rapid magnetic tripping when the selected short-circuit threshold is reached.
  • Thermal-magnetic operation without a separate electronic protection supply.
  • XT4S 250 A frame platform with a 200 A protective current rating.
  • Three-pole construction for appropriately designed three-phase circuits.
  • Fixed-mounted circuit breaker configuration on the corresponding XT4S TMA platform.
  • Front-terminal connection arrangement on the corresponding XT4S TMA platform.
  • Manual toggle-operated switching mechanism.
  • Mechanical trip indication through the operating mechanism.
  • Designed in accordance with IEC/EN 60947-2.
  • ABB manufacturer order code: 1SDX254974R1.

Advanced 200A Thermal-Magnetic Protection with 50kA Breaking Capacity

The ABB EPX-XT4S-TM2003 combines the mechanical switching and short-circuit interruption capabilities of the ABB SACE Tmax XT4S platform with an adjustable TMA thermal-magnetic trip unit. This arrangement provides protection against sustained overload conditions and short-circuit faults, helping protect electrical conductors, connected equipment and distribution infrastructure against abnormal current levels.

The thermal overload protection function responds to excessive current flowing for a sustained period. Its inverse-time characteristic means that larger overload currents generally result in faster tripping. For the 200 A TMA configuration, the thermal protection threshold can be adjusted between 140 A and 200 A, corresponding to 0.7–1.0 times the rated current. This flexibility allows the protection setting to be selected according to the conductor current-carrying capacity, expected load and installation design.

The magnetic short-circuit protection function provides rapid tripping when the current reaches the selected instantaneous operating threshold. For the corresponding 200 A TMA release, the magnetic threshold can be adjusted between 1,000 A and 2,000 A, equivalent to 5–10 times the rated current. These settings allow electrical designers to account for circuit characteristics and fault-current conditions when configuring short-circuit protection.

Unlike an electronic LSI trip unit, the TMA thermal-magnetic release does not provide a separately configurable short-time delayed protection function. Instead, it combines a time-dependent thermal overload response with an instantaneous magnetic short-circuit response. This makes it a practical choice for installations where adjustable thermal and magnetic thresholds meet the required protection and coordination objectives.

A key advantage of the XT4S breaking-capacity classification is its specified 50 kA short-circuit breaking capacity. This provides a higher fault-interruption rating than corresponding XT4N configurations with a 36 kA breaking capacity at the same reference conditions. The higher rating may be particularly valuable for distribution circuits installed close to a transformer, main switchboard or other point where prospective short-circuit currents can be substantial.

The corresponding ABB SACE Tmax XT4S IEC circuit breaker platform supports operation at voltages up to 690 V AC, although its short-circuit breaking capacity varies according to the system voltage. Consequently, the specified 50 kA rating must not be assumed to apply at every operating voltage. Electrical designers must confirm the appropriate voltage-dependent breaking capacity using ABB's technical data and compare it with the installation's calculated prospective fault current.

The XT4S 250 A frame platform provides the mechanical foundation for the 200 A TMA configuration. Although the frame is designed to accommodate protective ratings up to 250 A, the EPX-XT4S-TM2003 is specifically a 200 A rated circuit breaker. The frame rating must not be confused with the rated current of the installed protection release or the permissible current of the connected circuit.

The three-pole configuration provides coordinated switching and protection of three phase conductors in appropriately designed three-phase distribution systems. Because this is a three-pole MCCB, it does not incorporate a fourth switched neutral pole. Where neutral isolation is required, an appropriately specified four-pole device should be considered.

For installations using ABB Protecta Power distribution assemblies, the EPX-XT4S-TM2003 offers a high-current outgoing circuit protection solution. Correct selection of mounting accessories, cable terminations, enclosure arrangements and protective settings is essential. The standard TMA trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection, so any required additional protective functions must be specified separately.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial three-phase distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 200 A thermal-magnetic protection.
  • Distribution circuits requiring a 50 kA short-circuit breaking capacity.
  • Commercial building main and sub-distribution systems.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Mechanical plant and building services power distribution.
  • Electrical installations requiring adjustable thermal overload protection.
  • Three-phase equipment supply circuits with compatible operating and starting-current characteristics.
  • Electrical refurbishment and distribution board upgrades involving compatible ABB MCCBs.
  • Professional installations requiring robust, adjustable overcurrent protection.

Technical Specifications

Product group Protecta Power Devices
Product reference EPX-XT4S-TM2003
ABB order code 1SDX254974R1
Product type Moulded case circuit breaker (MCCB)
Series SACE Tmax XT4 / Protecta Power
Circuit breaker designation XT4S
Rated current (In) 200 A
Number of poles 3
Pole configuration 3P
Specified short-circuit breaking capacity 50 kA
Corresponding XT4S IEC breaking capacity 50 kA at 415 V AC
Breaking-capacity classification S
Trip unit type TMA adjustable thermal-magnetic
Protection technology Thermal-magnetic overcurrent release
Overload protection Adjustable thermal
Thermal adjustment range 0.7–1.0 × In
Thermal overload current setting 140–200 A
Thermal operating characteristic Inverse-time
Short-circuit protection Adjustable instantaneous magnetic
Magnetic adjustment range 5–10 × In
Magnetic short-circuit current setting 1,000–2,000 A
Magnetic operating characteristic Rapid tripping at the selected threshold
Trip-unit adjustment method Mechanical setting controls
Separate electronic trip-unit supply Not required
Frame family XT4S
Frame rating 250 A
Rated protective current 200 A
Corresponding XT4S platform operational voltage Up to 690 V AC
Corresponding XT4S platform insulation voltage (Ui) 1,000 V
Corresponding XT4S platform impulse withstand voltage (Uimp) 8 kV
Corresponding XT4S platform mounting Fixed
Corresponding XT4S platform terminals Front terminals
Operating mechanism Manual toggle-operated circuit breaker
Switching arrangement Three-pole simultaneous operation
Applicable circuit breaker standard IEC/EN 60947-2
Application Low-voltage three-phase electrical distribution

Frequently Asked Questions

What is the ABB EPX-XT4S-TM2003 used for?

The ABB EPX-XT4S-TM2003 is a 200 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an adjustable TMA thermal-magnetic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT4S-TM2003?

The EPX-XT4S-TM2003 has a 200 A rated current. Its thermal overload protection can be adjusted below the full rated current to suit appropriately designed electrical circuits.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT4S-TM2003 has a specified 50 kA short-circuit breaking capacity. The corresponding XT4S IEC breaker configuration has a 50 kA rating at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the circuit breaker.

What does TMA mean on an ABB MCCB?

TMA identifies an adjustable thermal-magnetic trip unit. It combines thermal protection against sustained overloads with instantaneous magnetic protection against short-circuit currents. Both protection thresholds can be adjusted within the specified ranges for the release.

What is the thermal overload adjustment range?

The 200 A TMA release provides a thermal overload adjustment range of 140–200 A, corresponding to 0.7–1.0 times the rated current. The appropriate setting must be selected according to conductor ratings, expected load and electrical installation requirements.

What is the magnetic short-circuit adjustment range?

The magnetic short-circuit protection threshold is adjustable between 1,000 A and 2,000 A, corresponding to 5–10 times the 200 A rated current. The setting should be selected according to the installation's fault-current conditions and protection coordination requirements.

What is the difference between XT4S and XT4N MCCBs?

XT4S and XT4N identify different breaking-capacity variants within the ABB SACE Tmax XT4 range. Corresponding XT4S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT4N configurations. The correct selection depends on the installation voltage and prospective short-circuit current.

What is the difference between the 200A trip rating and the 250A frame rating?

The 200 A trip rating identifies the circuit breaker's rated protective current, while the 250 A frame rating identifies the current rating of the XT4S frame platform used for this configuration. The EPX-XT4S-TM2003 is a 200 A protective device and must not be treated as a 250 A rated circuit breaker.

Is the ABB EPX-XT4S-TM2003 suitable for three-phase distribution systems?

Yes. Its three-pole (3P) configuration is designed for appropriately rated three-phase electrical distribution circuits requiring coordinated switching and protection of the three phase conductors. Where neutral switching is required, a suitable four-pole circuit breaker should be considered.

Does the ABB EPX-XT4S-TM2003 provide earth-leakage protection?

The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.

What is the ABB order code for the EPX-XT4S-TM2003?

The ABB manufacturer order code is 1SDX254974R1. The corresponding product reference is EPX-XT4S-TM2003, identifying the 200 A, three-pole, 50 kA adjustable thermal-magnetic MCCB within the ABB Protecta Power Devices range.

Trusted ABB Thermal-Magnetic Circuit Protection for Professional Installations

The ABB EPX-XT4S-TM2003 combines a 200 A three-pole configuration, 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection in a robust SACE Tmax XT4S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides dependable overload and short-circuit protection for professionally specified commercial and industrial low-voltage electrical distribution systems.