1SDX254972R1 ABB EPX-XT4S-TM1603 160A 3P 50kA MCCB - TMA

1SDX254972R1 ABB EPX-XT4S-TM1603 160A 3P 50kA MCCB – TMA

ABB EPX-XT4S-TM1603 is a 160 A three-pole moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and an adjustable TMA thermal-magnetic trip unit. Part of the ABB Protecta Power Devices range, it provides adjustable thermal overload and instantaneous magnetic short-circuit protection for commercial and industrial low-voltage distribution systems.

SKU: 1SDX254972R1Alt SKU: EPX-XT4S-TM1603MPN: 1SDX254972R1
Price
List Price £867.10 ex VAT
Your Price (ex VAT)
£867.10
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £867.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£867.10

Why Choose the ABB EPX-XT4S-TM1603 160A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-TM1603 is a 160 A three-pole moulded case circuit breaker (MCCB) designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining a 50 kA short-circuit breaking capacity with an adjustable TMA thermal-magnetic trip unit, this device offers dependable protection for installations where high fault-current interruption capability and practical protection settings are essential.

Part of the ABB Protecta Power Devices range, the EPX-XT4S-TM1603 uses the established ABB SACE Tmax XT4S circuit breaker platform. Its thermal-magnetic protection system incorporates an adjustable thermal overload element and an adjustable magnetic short-circuit element, enabling electrical designers to select appropriate protective thresholds for the connected circuit. The trip unit operates through thermal and magnetic principles without requiring a separate electronic protection supply.

With its 160 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT4S-TM1603 is suited to appropriately designed three-phase outgoing circuits in distribution boards, industrial control panels and commercial switchgear. Identified by ABB order code 1SDX254972R1, it provides a robust solution for compatible ABB Protecta Power installations requiring reliable switching, adjustable overcurrent protection and high short-circuit interruption performance.

Key Advantages of the ABB EPX-XT4S-TM1603

  • 160 A rated current supports appropriately designed three-phase distribution circuits and electrical loads.
  • Three-pole (3P) construction enables coordinated switching of three phase conductors.
  • 50 kA breaking capacity provides substantial short-circuit interruption capability.
  • TMA thermal-magnetic trip unit combines overload and short-circuit protection in one MCCB.
  • Adjustable thermal overload protection allows the protection threshold to be matched to circuit requirements.
  • Adjustable magnetic short-circuit protection provides flexibility when setting fault-current tripping thresholds.
  • Thermal adjustment range of 112–160 A supports suitable conductor and load protection settings.
  • Magnetic adjustment range of 800–1,600 A enables configuration of instantaneous short-circuit protection.
  • Thermal-magnetic operation requires no separate electronic trip-unit power supply.
  • ABB SACE Tmax XT4S technology offers established circuit breaker performance for professional installations.
  • S breaking-capacity classification provides a higher specified breaking capacity than the corresponding XT4N 36 kA variant.
  • Compact moulded case construction supports efficient integration into compatible distribution assemblies.
  • Manual switching and resetting provide straightforward local operation.
  • Designed for use with compatible ABB Protecta Power distribution systems.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • ABB SACE Tmax XT4S circuit breaker platform.
  • 160 A nominal current rating.
  • Three-pole (3P) switching configuration.
  • 50 kA rated short-circuit breaking capacity.
  • TMA adjustable thermal-magnetic protection release.
  • Adjustable thermal overload protection (L).
  • Thermal overload setting range: 0.7–1.0 × In.
  • Thermal overload current settings: 112–160 A.
  • Adjustable instantaneous magnetic protection (I).
  • Magnetic protection setting range: 5–10 × In.
  • Magnetic short-circuit current settings: 800–1,600 A.
  • Inverse-time thermal response to sustained overload conditions.
  • Rapid magnetic operation at the selected short-circuit threshold.
  • Front-accessible trip-unit adjustment controls.
  • XT4S 160 A frame platform.
  • Fixed-mounted breaker configuration on the corresponding XT4S TMA platform.
  • Front-terminal connection arrangement on the corresponding XT4S TMA platform.
  • Manual toggle-operated switching mechanism.
  • Designed to meet applicable IEC/EN 60947-2 circuit breaker requirements.
  • ABB order code: 1SDX254972R1.

Adjustable 160A Thermal-Magnetic Protection for Three-Phase Circuits

The ABB EPX-XT4S-TM1603 combines the switching and fault-interruption capabilities of the ABB SACE Tmax XT4S platform with a TMA thermal-magnetic protection release. This arrangement provides protection against two principal overcurrent conditions: sustained overloads and short circuits. The thermal element responds to excessive current over time, while the magnetic element operates rapidly when a sufficiently high fault current is detected.

The thermal overload protection is adjustable between 0.7 and 1.0 times the 160 A rated current, equivalent to 112–160 A. This enables the protection setting to be selected in accordance with conductor ratings, expected circuit loading and installation requirements. The thermal element uses an inverse-time characteristic, so the operating time generally decreases as the magnitude of the overload increases.

The magnetic short-circuit protection is adjustable between 5 and 10 times the rated current, equivalent to 800–1,600 A. This function provides a rapid response to high fault currents and can be configured to accommodate the electrical characteristics of the protected circuit. Magnetic settings must be selected with regard to prospective short-circuit currents, equipment starting currents and the required coordination with other protective devices.

Unlike an electronic LSI trip unit, a TMA thermal-magnetic release does not provide a separately configurable short-time delayed protection function. Instead, it uses a thermal overload characteristic and an instantaneous magnetic protection characteristic. This makes it a practical choice for circuits where adjustable thermal and magnetic thresholds meet the required protection and discrimination objectives.

The XT4S breaking-capacity classification offers a specified 50 kA short-circuit breaking capacity, compared with 36 kA for corresponding XT4N configurations at the relevant reference conditions. This higher rating can be valuable in electrical distribution systems with substantial prospective fault currents. However, breaking capacity varies with operating voltage, and the correct rating must be checked against the manufacturer's data for the intended installation.

The three-pole design provides coordinated operation of three phase conductors, making the EPX-XT4S-TM1603 suitable for appropriately designed three-phase electrical distribution circuits. It does not provide a fourth switched neutral pole. Where neutral isolation is required, the electrical designer should select a suitable four-pole configuration and verify the neutral arrangement against the installation requirements.

As part of the ABB Protecta Power Devices range, the EPX-XT4S-TM1603 is intended for use in compatible distribution assemblies. Correct installation requires confirmation of the board arrangement, mechanical mounting, electrical terminations, conductor sizes and any required connection accessories. The MCCB's 160 A rated current must be considered alongside the selected thermal setting and the current-carrying capacity of the protected conductors.

The standard TMA trip unit provides overload and short-circuit protection, not residual-current or earth-leakage protection. Where additional earth-leakage protection is required, it must be provided by an appropriately specified device or compatible protection arrangement. Final circuit breaker selection should be supported by fault-level calculations, protective device coordination studies and the applicable electrical installation standards.

Typical Applications

  • ABB Protecta Power distribution boards and compatible switchgear assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial three-phase power distribution panels.
  • 160 A three-phase outgoing circuits requiring thermal-magnetic protection.
  • Distribution circuits requiring a 50 kA short-circuit breaking capacity.
  • Commercial building main and sub-distribution systems.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Mechanical and electrical building services distribution.
  • Electrical circuits requiring adjustable thermal overload thresholds.
  • Three-phase equipment supply circuits with suitable starting-current characteristics.
  • Electrical refurbishment and upgrades involving compatible ABB MCCBs.
  • Professional electrical installations requiring robust, adjustable overcurrent protection.

Technical Specifications

Brand ABB
Product group Protecta Power Devices
Product reference EPX-XT4S-TM1603
ABB manufacturer order code 1SDX254972R1
Product category Moulded case circuit breaker (MCCB)
Manufacturer platform SACE Tmax XT4
Circuit breaker designation XT4S
Breaking-capacity variant S
Rated current (In) 160 A
Number of poles 3
Pole arrangement 3P
Specified short-circuit breaking capacity 50 kA
Reference breaking capacity for corresponding XT4S IEC breaker 50 kA at 415 V AC
Trip unit TMA
Trip technology Adjustable thermal-magnetic
Overload protection function Thermal (L)
Overload protection adjustment 0.7–1.0 × In
Thermal setting range 112–160 A
Overload operating characteristic Inverse-time
Short-circuit protection function Instantaneous magnetic (I)
Magnetic protection adjustment 5–10 × In
Magnetic setting range 800–1,600 A
Trip-unit adjustment Front-mounted setting controls
Separate electronic trip supply Not required
Frame family XT4S
Corresponding frame rating 160 A
Corresponding XT4S platform rated voltage Up to 690 V AC
Corresponding mounting configuration Fixed
Corresponding terminal configuration Front terminals
Switching mechanism Manual toggle operation
Applicable product standard IEC/EN 60947-2
Typical application Three-phase low-voltage electrical distribution

Frequently Asked Questions

What is the ABB EPX-XT4S-TM1603 used for?

The ABB EPX-XT4S-TM1603 is a 160 A three-pole moulded case circuit breaker used to protect appropriately designed low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT4S-TM1603?

The EPX-XT4S-TM1603 has a 160 A rated current. Its TMA thermal-magnetic trip unit provides adjustable thermal overload protection, allowing the thermal threshold to be selected below the full rated current where required.

What is the breaking capacity of this ABB MCCB?

The ABB EPX-XT4S-TM1603 has a specified 50 kA short-circuit breaking capacity. ABB's corresponding XT4S IEC breaker configuration is rated at 50 kA at 415 V AC. The applicable breaking capacity must always be checked against the installation voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT4S-TM1603?

TMA identifies an adjustable thermal-magnetic trip unit. It combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection, providing two complementary overcurrent protection functions.

What is the thermal overload adjustment range?

The 160 A TMA trip unit provides a thermal overload setting range of 112–160 A, equivalent to 0.7–1.0 times the rated current. The appropriate setting depends on conductor ratings, expected load and installation requirements.

What is the magnetic short-circuit adjustment range?

The magnetic short-circuit protection setting is adjustable between 800 A and 1,600 A, equivalent to 5–10 times the 160 A rated current. The setting should be selected according to the installation's fault-current conditions and protection coordination requirements.

What is the difference between XT4S and XT4N circuit breakers?

XT4S and XT4N identify different breaking-capacity variants within the ABB SACE Tmax XT4 range. Corresponding XT4S configurations provide a 50 kA breaking capacity at 415 V AC, compared with 36 kA for XT4N configurations. The correct version depends on the installation voltage and prospective short-circuit current.

Is the ABB EPX-XT4S-TM1603 suitable for three-phase systems?

Yes. Its three-pole configuration is designed for coordinated switching and protection of three phase conductors in appropriately rated three-phase electrical distribution circuits. It does not include a fourth switched neutral pole.

Does the ABB EPX-XT4S-TM1603 provide earth-leakage protection?

No. The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriately specified additional protective device or compatible arrangement must be provided.

What is the ABB order code for the EPX-XT4S-TM1603?

The ABB manufacturer order code is 1SDX254972R1. The corresponding product reference is EPX-XT4S-TM1603, identifying the 160 A, three-pole, 50 kA TMA thermal-magnetic MCCB within the ABB Protecta Power Devices range.

Trusted ABB Circuit Protection for Professional Installations

The ABB EPX-XT4S-TM1603 combines a 160 A three-pole design, 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection in a robust SACE Tmax XT4S moulded case circuit breaker. Designed for compatible ABB Protecta Power assemblies, it provides dependable overload and short-circuit protection for professionally specified commercial and industrial electrical distribution systems.