Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT4S-TM1003 is a 100 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.
£688.49
The ABB EPX-XT4S-TM1003 is a robust 100 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT4S 160 A frame platform, combining dependable thermal-magnetic protection with substantial short-circuit interruption capability for commercial, industrial and building services installations.
Equipped with an ABB TMA thermal-magnetic trip unit, the EPX-XT4S-TM1003 provides thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect cables and connected equipment against overheating, while the magnetic element provides rapid circuit interruption when short-circuit current reaches the applicable trip threshold. The TMA protection system offers adjustable trip characteristics without requiring an electronic trip unit or external auxiliary power supply.
With a rated current of 100 A, a three-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for protecting three-phase outgoing feeders and distribution circuits. Its ABB XT4S construction supports integration into compatible Protecta Power distribution boards, making it a practical choice for electrical contractors, panel builders, consulting engineers and maintenance professionals.
The ABB EPX-XT4S-TM1003 provides circuit protection through the combined operation of thermal and magnetic trip mechanisms. During sustained overload conditions, the thermal protection element responds to excessive current according to its time-current characteristics. This helps prevent prolonged overheating of electrical conductors, terminals and connected equipment. During short-circuit conditions, the magnetic protection element responds rapidly when fault current reaches the applicable trip threshold, initiating circuit interruption to reduce the consequences of electrical faults.
The ABB TMA trip unit provides conventional thermal-magnetic protection with adjustable characteristics suited to the selected breaker configuration. This allows electrical designers to coordinate overload protection with conductor capacity and evaluate short-circuit performance against the electrical installation's prospective fault current. Unlike electronic trip units, the thermal-magnetic system does not rely on electronic current measurement for its basic protective functions. The actual setting ranges should be confirmed from the markings and technical documentation for the supplied circuit breaker.
The ABB SACE Tmax XT4S platform combines robust moulded case construction with a specified 50 kA short-circuit breaking capacity, making the EPX-XT4S-TM1003 suitable for appropriately engineered distribution systems requiring substantial fault interruption capability. Its three-pole configuration is designed for three-phase circuits, while compatibility with ABB Protecta Power distribution assemblies helps simplify equipment selection for panel building and installation projects. Electrical engineers should verify the applicable operating voltage, prospective short-circuit current, protection settings and coordination with other protective devices before commissioning.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT4 |
| Product model | EPX-XT4S-TM1003 |
| ABB order code | 1SDX254970R1 |
| Corresponding ABB circuit breaker reference | 1SDA068307R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT4S 160 |
| Frame current class | 160 A |
| Rated current (In) | 100 A |
| Number of poles | 3 |
| Specified short-circuit breaking capacity | 50 kA |
| Trip unit technology | Thermal-magnetic |
| Trip unit designation | TMA |
| Overload protection | Thermal trip mechanism |
| Short-circuit protection | Magnetic trip mechanism |
| Thermal protection adjustment | According to the TMA trip unit setting range |
| Magnetic protection characteristic | According to the TMA trip unit configuration |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase |
| Operating mechanism | Manual toggle operation |
| Primary function | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT4S-TM1003 is a 100 A three-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT4S-TM1003 has a 100 A rated current and uses the ABB SACE Tmax XT4S 160 A frame platform. The 160 A frame designation identifies the current class of the circuit breaker platform rather than the rated current of this individual device.
The EPX-XT4S-TM1003 has a specified 50 kA short-circuit breaking capacity. The applicable rated operating voltage and manufacturer short-circuit performance conditions must be verified against the prospective fault current at the installation location.
TMA identifies a thermal-magnetic trip unit that combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid tripping during short-circuit conditions.
The ABB TMA trip unit provides adjustable thermal-magnetic protection characteristics according to its specific configuration. The available adjustment ranges should be checked against the supplied device and selected to suit conductor ratings, connected equipment and the electrical installation's protection requirements.
XT4N and XT4S identify different short-circuit performance versions within the ABB SACE Tmax XT4 family. The corresponding ABB Protecta Power XT4N devices are specified at 36 kA, while XT4S versions are specified at 50 kA. Selection should be based on the prospective fault current and the applicable operating voltage.
Yes. The EPX-XT4S-TM1003 has a three-pole configuration designed for switching and protecting three phase conductors. It is suitable for appropriately designed three-phase low-voltage distribution circuits where neutral switching through the breaker is not required.
Yes. The EPX-XT4S-TM1003 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT4 mounting arrangement, electrical connections, enclosure compatibility and protection settings should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining robust construction, practical thermal-magnetic protection and dependable short-circuit interruption capability for modern low-voltage power systems.