1SDX254969R1 ABB EPX-XT4S-TM0803 80A 3-Pole 50kA TMA MCCB

1SDX254969R1 ABB EPX-XT4S-TM0803 80A 3-Pole 50kA TMA MCCB

ABB EPX-XT4S-TM0803 is an 80 A three-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA ultimate short-circuit breaking capacity at 415 V AC and adjustable TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX254969R1Alt SKU: EPX-XT4S-TM0803MPN: 1SDX254969R1
Price
List Price £688.49 ex VAT
Your Price (ex VAT)
£688.49
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £688.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£688.49

Why Choose the ABB EPX-XT4S-TM0803 80A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-TM0803 is a high-performance 80 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT4S160 platform, delivering reliable electrical protection for commercial buildings, industrial facilities and electrical infrastructure.

Equipped with an ABB TMA thermal-magnetic trip unit, the EPX-XT4S-TM0803 combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption when short-circuit current reaches the selected trip threshold. These complementary protection functions help safeguard electrical cables, switchgear and connected equipment while allowing protection settings to be matched to the requirements of the installation.

With an 80 A rated current, three-pole construction and 50 kA rated ultimate short-circuit breaking capacity at 415 V AC, this MCCB is suitable for three-phase electrical distribution circuits requiring substantial fault-interruption capability. Its XT4S160 frame, fixed-mounted construction and front terminal connections support integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • 80 A rated current for commercial and industrial electrical distribution circuits.
  • Three-pole configuration suitable for three-phase low-voltage electrical systems.
  • 50 kA breaking capacity at 415 V AC provides substantial short-circuit fault-interruption capability.
  • ABB TMA thermal-magnetic trip unit combines adjustable overload and short-circuit protection in one device.
  • Adjustable thermal protection helps safeguard electrical cables against sustained excessive current.
  • Adjustable magnetic protection allows short-circuit tripping characteristics to be configured according to circuit requirements.
  • Thermal adjustment range of 56–80 A provides flexibility when setting overload protection.
  • Magnetic adjustment range of 400–800 A supports appropriate short-circuit protection coordination.
  • ABB Tmax XT4S160 frame offers robust construction for demanding electrical distribution applications.
  • Fixed-mounted design supports secure installation in compatible electrical assemblies.
  • Front terminal arrangement facilitates electrical connections during installation.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT4S160 moulded case circuit breaker platform.
  • 80 A rated current.
  • Three-pole (3P) construction.
  • 50 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • TMA thermal-magnetic trip unit.
  • Adjustable thermal overload protection from 56–80 A.
  • Adjustable magnetic short-circuit protection from 400–800 A.
  • Thermal adjustment range: 0.7–1 × In.
  • Magnetic adjustment range: 5–10 × In.
  • XT4S160 frame with a maximum frame rating of 160 A.
  • Fixed-mounted construction for compatible distribution assemblies.
  • Front terminal connections for electrical conductor termination.
  • Manual toggle operating mechanism with trip indication and reset capability.
  • Three-pole switching and protection for three-phase electrical circuits.
  • Designed for low-voltage electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT4 installation accessories.

Adjustable Thermal-Magnetic Protection for Industrial Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT4S-TM0803 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Its TMA thermal-magnetic trip unit incorporates adjustable thermal protection against sustained overcurrent and an adjustable magnetic element for rapid short-circuit fault interruption. The thermal setting range of 56–80 A and magnetic setting range of 400–800 A allow protection characteristics to be configured according to conductor requirements, connected loads and coordination with other protective devices.

The ABB SACE Tmax XT4 circuit breaker family is engineered for dependable protection in modern low-voltage distribution assemblies. The EPX-XT4S-TM0803 is particularly suitable for installations requiring 80 A three-pole circuit protection and a 50 kA short-circuit breaking rating at 415 V AC. Circuit breaker selection should account for operating voltage, prospective fault current, conductor characteristics, load requirements and protective device coordination. Where the MCCB supplies a motor circuit, dedicated motor overload protection may also be necessary depending on the installation design.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuits and electrical feeders.
  • Manufacturing facilities and industrial workshops.
  • Building services and commercial electrical infrastructure.
  • Warehouses, logistics centres and production facilities.
  • Industrial control panels requiring adjustable thermal-magnetic protection.
  • Electrical distribution circuits requiring high short-circuit breaking capacity.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT4S160
ABB order code 1SDX254969R1
Corresponding ABB circuit breaker reference 1SDA068306R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 80 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Trip unit TMA
Trip unit technology Thermal-magnetic
Thermal overload protection setting 56–80 A
Thermal adjustment 0.7–1 × In
Magnetic short-circuit protection setting 400–800 A
Magnetic adjustment 5–10 × In
Protection functions Adjustable thermal overload and magnetic short-circuit protection
Frame family XT4S160
Maximum frame rating 160 A
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual toggle operation
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0803 used for?

The ABB EPX-XT4S-TM0803 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial three-phase electrical installations.

What is the rated current of the EPX-XT4S-TM0803?

The circuit breaker has an 80 A rated current and uses the ABB Tmax XT4S160 frame, which has a maximum frame rating of 160 A. Its adjustable thermal overload protection setting ranges from 56–80 A.

What is the breaking capacity of the ABB EPX-XT4S-TM0803?

The EPX-XT4S-TM0803 has a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current before selection.

What protection does the TMA thermal-magnetic trip unit provide?

The ABB TMA thermal-magnetic trip unit provides adjustable thermal overload protection and adjustable magnetic short-circuit protection. For this 80 A configuration, the thermal adjustment range is 56–80 A, while the magnetic adjustment range is 400–800 A.

Where is the ABB EPX-XT4S-TM0803 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies. Its fixed-mounted construction, front terminal connections and three-pole configuration support integration into suitable three-phase electrical distribution panels.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT4S-TM0803 combines an 80 A rating, three-pole construction, 50 kA breaking capacity at 415 V AC and adjustable TMA thermal-magnetic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.