1SDX254966R1 ABB EPX-XT4S-TM0633 63A 3-Pole 50kA TMA MCCB

1SDX254966R1 ABB EPX-XT4S-TM0633 63A 3-Pole 50kA TMA MCCB

ABB EPX-XT4S-TM0633 is a 63 A three-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit with adjustable magnetic protection for low-voltage electrical distribution systems.

SKU: 1SDX254966R1Alt SKU: EPX-XT4S-TM0633MPN: 1SDX254966R1
Price
List Price £678.40 ex VAT
Your Price (ex VAT)
£678.40
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £678.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£678.40

Why Choose the ABB EPX-XT4S-TM0633 63A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-TM0633 is a high-performance 63 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the proven ABB SACE Tmax XT4S160 platform, offering reliable electrical protection for commercial buildings, industrial facilities and electrical infrastructure.

Equipped with an ABB TMA thermal-magnetic trip unit, the EPX-XT4S-TM0633 combines thermal overload protection with adjustable magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption when short-circuit current reaches the selected trip threshold. These complementary protection functions help safeguard electrical cables, switchgear and connected equipment against damaging fault conditions.

With a 63 A rated current, three-pole construction and 50 kA short-circuit breaking capacity, this MCCB is suitable for three-phase electrical distribution circuits requiring substantial fault-interruption capability. Its XT4S160 frame, fixed-mounted construction and front terminal connections support integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • 63 A rated current for commercial and industrial electrical distribution circuits.
  • Three-pole configuration suitable for three-phase low-voltage electrical systems.
  • 50 kA short-circuit breaking capacity provides substantial fault-interruption capability.
  • ABB TMA thermal-magnetic trip unit combines overload and short-circuit protection in one device.
  • Thermal overload protection helps safeguard electrical cables against sustained excessive current.
  • Adjustable magnetic protection allows short-circuit tripping characteristics to be configured according to circuit requirements.
  • Magnetic trip adjustment range of 315–630 A supports appropriate protection settings.
  • ABB Tmax XT4S160 frame offers robust construction for demanding electrical distribution applications.
  • Compact three-pole design supports efficient installation in compatible switchboards.
  • Fixed-mounted construction provides a practical arrangement for electrical distribution assemblies.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT4S160 moulded case circuit breaker platform.
  • 63 A rated current.
  • Three-pole (3P) construction.
  • 50 kA short-circuit breaking capacity.
  • TMA thermal-magnetic trip unit.
  • Thermal overload protection against sustained overcurrent conditions.
  • Adjustable magnetic short-circuit protection from 315–630 A.
  • Magnetic adjustment range: 5–10 × In.
  • XT4S160 frame with a maximum frame rating of 160 A.
  • Fixed-mounted construction for compatible distribution assemblies.
  • Front terminal connections for electrical conductor termination.
  • Manual operating mechanism with mechanical trip indication and reset capability.
  • Three-pole switching and protection for three-phase electrical circuits.
  • Designed for low-voltage electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT4 installation accessories.

Reliable Thermal-Magnetic Protection for Industrial Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT4S-TM0633 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Its TMA thermal-magnetic trip unit incorporates thermal protection against sustained overcurrent and an adjustable magnetic element for rapid short-circuit fault interruption. The magnetic setting range of 315–630 A allows the short-circuit trip threshold to be configured according to the electrical circuit and protection coordination requirements.

The ABB SACE Tmax XT4 circuit breaker family is engineered for dependable protection in modern low-voltage distribution assemblies. The EPX-XT4S-TM0633 is particularly suitable for installations requiring 63 A three-pole circuit protection and a 50 kA short-circuit breaking rating. Circuit breaker selection should account for operating voltage, prospective fault current, conductor characteristics, load requirements and protective device coordination. Where the MCCB supplies a motor circuit, dedicated motor overload protection may also be necessary depending on the installation design.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuits and electrical feeders.
  • Manufacturing facilities and industrial workshops.
  • Building services and commercial electrical infrastructure.
  • Warehouses, logistics centres and production facilities.
  • Industrial control panels requiring thermal-magnetic protection.
  • Electrical distribution circuits requiring high short-circuit breaking capacity.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT4S160
ABB order code 1SDX254966R1
Corresponding ABB circuit breaker reference 1SDA068305R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 63 A
Number of poles 3
Short-circuit breaking capacity 50 kA
Trip unit TMA
Trip unit technology Thermal-magnetic
Overload protection Thermal trip element
Short-circuit protection Adjustable magnetic trip element
Magnetic short-circuit protection setting 315–630 A
Magnetic adjustment 5–10 × In
Protection functions Thermal overload and magnetic short-circuit protection
Frame family XT4S160
Maximum frame rating 160 A
Rated operational voltage Up to 690 V AC
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual operation
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0633 used for?

The ABB EPX-XT4S-TM0633 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial three-phase electrical installations.

What is the rated current of the EPX-XT4S-TM0633?

The circuit breaker has a 63 A rated current and uses the ABB Tmax XT4S160 frame, which has a maximum frame rating of 160 A. The rated current of this specific MCCB is 63 A, not the maximum rating of its frame.

What is the breaking capacity of the ABB EPX-XT4S-TM0633?

The EPX-XT4S-TM0633 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation's operating voltage must be verified against ABB technical documentation and the prospective fault current before selection.

What protection does the TMA thermal-magnetic trip unit provide?

The ABB TMA thermal-magnetic trip unit provides thermal overload protection and adjustable magnetic short-circuit protection. For this 63 A configuration, the magnetic trip setting can be adjusted from 315–630 A, equivalent to 5–10 times the rated current.

Where is the ABB EPX-XT4S-TM0633 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies. Its fixed-mounted construction, front terminal connections and three-pole configuration support integration into suitable three-phase electrical distribution panels.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT4S-TM0633 combines a 63 A rating, three-pole construction, 50 kA breaking capacity and TMA thermal-magnetic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.