1SDX254963R1 ABB EPX-XT4S-TM0503 50A 3-Pole 50kA TMA MCCB

1SDX254963R1 ABB EPX-XT4S-TM0503 50A 3-Pole 50kA TMA MCCB

ABB EPX-XT4S-TM0503 is a 50 A three-pole moulded case circuit breaker with 50 kA breaking capacity and an adjustable thermal-magnetic trip unit, designed for overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX254963R1Alt SKU: EPX-XT4S-TM0503MPN: 1SDX254963R1
Price
List Price £678.40 ex VAT
Your Price (ex VAT)
£678.40
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £678.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£678.40

Why Choose the ABB EPX-XT4S-TM0503 50A 3-Pole MCCB?

The ABB EPX-XT4S-TM0503 is a high-performance 50 A, 3-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity and a thermal-magnetic adjustable (TMA) trip unit, this circuit breaker offers reliable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power Devices range, the EPX-XT4S-TM0503 incorporates proven ABB SACE Tmax XT4S circuit breaker technology. Its thermal-magnetic protection system combines adjustable thermal overload protection with magnetic short-circuit protection, helping safeguard electrical cables, distribution equipment and connected circuits against potentially damaging fault conditions.

With a 50 A rated current, three-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT4S-TM0503 is suitable for three-phase power distribution applications. Its compact XT4S160 frame, fixed mounting arrangement and front terminal connections support straightforward integration into electrical switchboards, distribution boards and industrial control panels.

Key Advantages

  • 50 A rated current suitable for low-voltage electrical distribution circuits.
  • 50 kA breaking capacity provides protection against high prospective short-circuit currents at the applicable rated voltage.
  • Three-pole construction enables simultaneous switching and protection of three-phase circuits.
  • Thermal-magnetic adjustable (TMA) trip unit provides overload and short-circuit protection.
  • Adjustable thermal and magnetic protection settings support coordination with installation requirements.
  • ABB SACE Tmax XT4S160 platform combines reliable circuit protection with compact construction.
  • Fixed mounting arrangement with front terminals simplifies integration into suitable electrical assemblies.
  • Designed for use within ABB Protecta Power distribution systems and compatible low-voltage switchgear.

Key Features

  • ABB Protecta Power Devices moulded case circuit breaker.
  • SACE Tmax XT4S160 circuit breaker platform.
  • 50 A rated current for electrical distribution protection.
  • 50 kA short-circuit breaking capacity at the specified operating voltage.
  • Three-pole configuration for three-phase electrical systems.
  • TMA thermal-magnetic adjustable release with overload and instantaneous short-circuit protection.
  • Adjustable instantaneous magnetic trip setting of 250–500 A.
  • Fixed installation design with front terminal connections.
  • 690 V AC rated operational voltage for the corresponding XT4S circuit breaker platform.
  • Mechanical operating mechanism with manual switching and automatic protective tripping.
  • Compact construction for low-voltage distribution boards and switchgear assemblies.
  • Designed in accordance with IEC 60947-2 circuit breaker requirements.

Reliable Thermal-Magnetic Circuit Protection

The ABB EPX-XT4S-TM0503 protects electrical distribution circuits through a combination of thermal and magnetic tripping mechanisms. The thermal element responds to sustained overload conditions, while the magnetic element provides rapid interruption when high short-circuit currents occur. The adjustable protection settings allow the circuit breaker to be configured according to the electrical characteristics and protection requirements of the installation.

The ABB SACE Tmax XT4S platform is designed for reliable operation in low-voltage electrical networks. Its robust moulded case construction, fixed mounting configuration and front terminal connections support secure installation in distribution assemblies. With a 50 kA breaking capacity and 50 A rated current, this MCCB provides an effective solution for protecting three-phase distribution circuits against overloads and short circuits.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power low-voltage distribution assemblies.
  • Three-phase electrical distribution and feeder circuits.
  • Industrial machinery and equipment supply circuits.
  • Electrical switchboards and control panels.
  • Building services and infrastructure power distribution.
  • Manufacturing facilities and industrial electrical installations.
  • Sub-distribution circuits requiring adjustable thermal-magnetic protection.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT4S
ABB order code 1SDX254963R1
Product type Moulded case circuit breaker (MCCB)
Rated current 50 A
Number of poles 3
Breaking capacity 50 kA
Trip unit TMA – thermal-magnetic adjustable
Magnetic trip adjustment 250–500 A
Protection functions Thermal overload and magnetic short-circuit protection
Frame designation XT4S160
Frame rated current 160 A
Rated operational voltage Up to 690 V AC
Number of phases Three-phase application
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Mechanical toggle operation
Applicable standard IEC 60947-2
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0503 used for?

The ABB EPX-XT4S-TM0503 is a moulded case circuit breaker used to protect three-phase low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT4S-TM0503?

The circuit breaker has a 50 A rated current and belongs to the ABB SACE Tmax XT4S160 frame family.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4S-TM0503 has a specified 50 kA breaking capacity. The applicable rated voltage and installation conditions should be verified when selecting the breaker for a particular electrical system.

What does TMA mean on the ABB EPX-XT4S-TM0503?

TMA means thermal-magnetic adjustable. The trip unit provides thermal overload protection and magnetic short-circuit protection, with an adjustable instantaneous magnetic trip setting of 250–500 A.

Where is the ABB EPX-XT4S-TM0503 typically installed?

This MCCB is typically installed in electrical distribution boards, switchboards and industrial control panels, including suitable ABB Protecta Power assemblies, using its fixed mounting arrangement and front terminal connections.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT moulded case circuit breakers are engineered to provide dependable electrical protection in commercial and industrial low-voltage distribution systems. The EPX-XT4S-TM0503 combines a 50 A current rating, three-pole construction, 50 kA breaking capacity and adjustable thermal-magnetic protection to support safe and reliable electrical distribution.