Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT4S-TM0323 is a 32 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution.
£678.40
The ABB EPX-XT4S-TM0323 is a 32 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker is suitable for commercial, industrial and infrastructure installations requiring reliable electrical protection.
Part of the ABB Protecta Power Devices range, the EPX-XT4S-TM0323 belongs to the ABB SACE Tmax XT4S circuit breaker family. Its TMA protection release combines thermal overload protection with magnetic short-circuit protection, helping safeguard electrical conductors, distribution equipment and connected circuits against abnormal current conditions.
With its 32 A rated current, three-pole configuration and 50 kA breaking capacity, the EPX-XT4S-TM0323 is a practical solution for three-phase electrical distribution circuits where relatively modest continuous currents must be protected against potentially high fault levels. The ABB Tmax XT4S platform provides robust circuit protection for electrical contractors, panel builders and industrial maintenance professionals.
The ABB EPX-XT4S-TM0323 incorporates a TMA thermal-magnetic protection release designed to respond to overload and short-circuit conditions. The thermal element provides an inverse-time response to sustained excessive currents, helping protect conductors and connected equipment against overheating. The magnetic element provides rapid fault interruption when the current reaches the applicable short-circuit tripping threshold. Protection settings should be selected according to the manufacturer's technical documentation and the requirements of the electrical installation.
The ABB SACE Tmax XT4S platform combines dependable protective operation with robust construction suitable for low-voltage distribution equipment. With a 32 A rated current, three-pole switching arrangement and 50 kA breaking capacity, the EPX-XT4S-TM0323 provides a practical solution for distribution feeders, industrial control panel supplies and electrical circuits requiring high fault interruption capability. Correct selection must consider the installation voltage, prospective short-circuit current, conductor ratings and protection coordination.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker family | SACE Tmax XT |
| Series | XT4S |
| ABB order code | 1SDX254960R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 32 A |
| Number of poles | 3 |
| Short-circuit breaking capacity | 50 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Frame family | XT4 |
| Breaking capacity class | S |
| Operating mechanism | Manual switching with automatic protective tripping |
| Application | Low-voltage three-phase electrical distribution |
| Circuit breaker standard | IEC 60947-2 |
The ABB EPX-XT4S-TM0323 is a 32 A three-pole MCCB used to protect low-voltage electrical distribution circuits against overloads and short circuits.
The EPX-XT4S-TM0323 has a rated current of 32 A. The connected load, conductor ratings and installation conditions must be considered when selecting the circuit breaker.
The EPX-XT4S-TM0323 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation voltage must be verified against the prospective fault current.
TMA identifies a thermal-magnetic trip unit with adjustable protection functionality. Thermal protection responds to sustained overloads, while magnetic protection responds to short-circuit faults.
The TMA designation indicates adjustable thermal-magnetic protection functionality. The available settings and adjustment ranges must be checked against the technical documentation for the supplied device.
Yes. The EPX-XT4S-TM0323 has a three-pole (3P) configuration suitable for appropriately designed three-phase electrical distribution applications.
The EPX-XT4S-TM0323 belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT4S circuit breaker platform.
The S designation identifies a breaking capacity class within the ABB SACE Tmax XT4 family. The EPX-XT4S-TM0323 has a specified breaking capacity of 50 kA.
Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its current rating, breaking capacity, protection characteristics and installation requirements match the application.
The ABB order code is 1SDX254960R1, identifying this model within the ABB Protecta Power Devices range.
ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, contractors and maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT4S-TM0323 combines a 32 A rated current, three-pole configuration and 50 kA breaking capacity with TMA thermal-magnetic protection, making it a practical choice for commercial and industrial electrical distribution.