1SDX254960R1 ABB EPX-XT4S-TM0323 32A 3-Pole 50kA TMA Moulded Case Circuit Breaker

1SDX254960R1 ABB EPX-XT4S-TM0323 32A 3-Pole 50kA TMA Moulded Case Circuit Breaker

ABB EPX-XT4S-TM0323 is a 32 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution.

SKU: 1SDX254960R1Alt SKU: EPX-XT4S-TM0323MPN: 1SDX254960R1
Price
List Price £678.40 ex VAT
Your Price (ex VAT)
£678.40
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £678.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£678.40

Why Choose the ABB EPX-XT4S-TM0323 32A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-TM0323 is a 32 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker is suitable for commercial, industrial and infrastructure installations requiring reliable electrical protection.

Part of the ABB Protecta Power Devices range, the EPX-XT4S-TM0323 belongs to the ABB SACE Tmax XT4S circuit breaker family. Its TMA protection release combines thermal overload protection with magnetic short-circuit protection, helping safeguard electrical conductors, distribution equipment and connected circuits against abnormal current conditions.

With its 32 A rated current, three-pole configuration and 50 kA breaking capacity, the EPX-XT4S-TM0323 is a practical solution for three-phase electrical distribution circuits where relatively modest continuous currents must be protected against potentially high fault levels. The ABB Tmax XT4S platform provides robust circuit protection for electrical contractors, panel builders and industrial maintenance professionals.

Key Advantages

  • 32 A rated current suitable for appropriately designed commercial and industrial electrical circuits.
  • 50 kA breaking capacity provides substantial short-circuit interruption capability.
  • Three-pole configuration supports protection of three-phase electrical distribution systems.
  • TMA thermal-magnetic trip unit combines overload and short-circuit protection.
  • Thermal overload protection helps prevent damage caused by sustained excessive current.
  • Magnetic short-circuit protection provides rapid tripping during sufficiently high fault currents.
  • Adjustable protection functionality supports appropriate coordination with the electrical installation.
  • ABB SACE Tmax XT4S technology provides dependable switching and protective operation.
  • High breaking capacity relative to rated current makes the device suitable for circuits with demanding fault-level requirements.
  • Manual switching with automatic protective tripping combines circuit control and electrical protection.
  • Protecta Power application supports integration into compatible ABB electrical distribution assemblies.

Key Features

  • ABB EPX-XT4S-TM0323 moulded case circuit breaker.
  • 32 A rated current.
  • Three-pole (3P) configuration.
  • 50 kA short-circuit breaking capacity.
  • ABB SACE Tmax XT4S circuit breaker platform.
  • TMA thermal-magnetic protection release.
  • Thermal protection against sustained overload currents.
  • Magnetic protection against short-circuit faults.
  • Automatic protective tripping under applicable overcurrent conditions.
  • Manual operating mechanism for circuit switching.
  • Three-pole switching arrangement for three-phase applications.
  • S breaking capacity class within the ABB Tmax XT4 family.
  • Designed for low-voltage AC electrical distribution.
  • Suitable for appropriately configured ABB Protecta Power distribution equipment.
  • Supports commercial and industrial electrical panel applications.

Thermal-Magnetic Protection for Three-Phase Electrical Distribution

The ABB EPX-XT4S-TM0323 incorporates a TMA thermal-magnetic protection release designed to respond to overload and short-circuit conditions. The thermal element provides an inverse-time response to sustained excessive currents, helping protect conductors and connected equipment against overheating. The magnetic element provides rapid fault interruption when the current reaches the applicable short-circuit tripping threshold. Protection settings should be selected according to the manufacturer's technical documentation and the requirements of the electrical installation.

The ABB SACE Tmax XT4S platform combines dependable protective operation with robust construction suitable for low-voltage distribution equipment. With a 32 A rated current, three-pole switching arrangement and 50 kA breaking capacity, the EPX-XT4S-TM0323 provides a practical solution for distribution feeders, industrial control panel supplies and electrical circuits requiring high fault interruption capability. Correct selection must consider the installation voltage, prospective short-circuit current, conductor ratings and protection coordination.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution circuits.
  • 32 A outgoing feeders and distribution circuits.
  • Industrial control panel supply circuits.
  • Electrical panels requiring substantial short-circuit breaking capacity.
  • Manufacturing and production facilities.
  • Commercial building electrical infrastructure.
  • Warehouses and logistics installations.
  • Electrical panel building and switchgear assembly projects.
  • Distribution circuits requiring thermal overload and magnetic short-circuit protection.
  • Electrical maintenance, refurbishment and distribution system upgrades.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4S
ABB order code 1SDX254960R1
Product type Moulded case circuit breaker (MCCB)
Rated current 32 A
Number of poles 3
Short-circuit breaking capacity 50 kA
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Frame family XT4
Breaking capacity class S
Operating mechanism Manual switching with automatic protective tripping
Application Low-voltage three-phase electrical distribution
Circuit breaker standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0323 used for?

The ABB EPX-XT4S-TM0323 is a 32 A three-pole MCCB used to protect low-voltage electrical distribution circuits against overloads and short circuits.

What is the rated current of the EPX-XT4S-TM0323?

The EPX-XT4S-TM0323 has a rated current of 32 A. The connected load, conductor ratings and installation conditions must be considered when selecting the circuit breaker.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4S-TM0323 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation voltage must be verified against the prospective fault current.

What does TMA mean on the ABB EPX-XT4S-TM0323?

TMA identifies a thermal-magnetic trip unit with adjustable protection functionality. Thermal protection responds to sustained overloads, while magnetic protection responds to short-circuit faults.

Does the ABB EPX-XT4S-TM0323 provide adjustable protection?

The TMA designation indicates adjustable thermal-magnetic protection functionality. The available settings and adjustment ranges must be checked against the technical documentation for the supplied device.

Is the EPX-XT4S-TM0323 a three-pole circuit breaker?

Yes. The EPX-XT4S-TM0323 has a three-pole (3P) configuration suitable for appropriately designed three-phase electrical distribution applications.

What ABB circuit breaker series does this model belong to?

The EPX-XT4S-TM0323 belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT4S circuit breaker platform.

What does the S designation mean in XT4S?

The S designation identifies a breaking capacity class within the ABB SACE Tmax XT4 family. The EPX-XT4S-TM0323 has a specified breaking capacity of 50 kA.

Can the EPX-XT4S-TM0323 be used in industrial distribution panels?

Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its current rating, breaking capacity, protection characteristics and installation requirements match the application.

What is the ABB order code for the EPX-XT4S-TM0323?

The ABB order code is 1SDX254960R1, identifying this model within the ABB Protecta Power Devices range.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, contractors and maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT4S-TM0323 combines a 32 A rated current, three-pole configuration and 50 kA breaking capacity with TMA thermal-magnetic protection, making it a practical choice for commercial and industrial electrical distribution.