ABB EPX-XT4S-TM0253 is a 25 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection for low-voltage commercial and industrial electrical distribution.
£678.40
The ABB EPX-XT4S-TM0253 is a 25 A three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short circuits. Featuring a 50 kA short-circuit breaking capacity and TMA thermal-magnetic protection, this circuit breaker provides dependable protection for commercial, industrial and infrastructure electrical installations.
Part of the ABB Protecta Power Devices range, the EPX-XT4S-TM0253 is associated with the ABB SACE Tmax XT4S circuit breaker family. Its thermal-magnetic protection combines a thermal element for overload detection with a magnetic element for short-circuit fault response. This protection arrangement provides an established solution for electrical installations requiring automatic disconnection under abnormal current conditions.
With a 25 A rated current, three-pole configuration and 50 kA breaking capacity, the EPX-XT4S-TM0253 is suitable for appropriately designed three-phase electrical distribution circuits. The XT4S platform provides a robust MCCB solution for panel builders, electrical contractors and maintenance engineers working with compatible ABB Protecta Power distribution equipment.
The ABB EPX-XT4S-TM0253 uses thermal-magnetic protection principles to respond to two important electrical fault conditions. The thermal element responds to sustained overload currents, helping protect conductors and connected equipment against excessive heating. The magnetic element responds rapidly to short-circuit currents, allowing the breaker to disconnect the affected circuit when its magnetic tripping threshold is reached. The exact protection characteristics should be confirmed against the release documentation for the supplied device.
The ABB SACE Tmax XT4S platform provides a robust foundation for low-voltage circuit protection. Combining a 25 A current rating, three-pole construction and 50 kA breaking capacity, the EPX-XT4S-TM0253 is suitable for electrical distribution applications where relatively modest continuous load currents must be protected in systems with potentially significant short-circuit fault levels. Correct selection requires consideration of the operating voltage, prospective fault current, conductor ratings and protective coordination requirements.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker family | SACE Tmax XT |
| Series | XT4S |
| ABB order code | 1SDX254958R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 25 A |
| Number of poles | 3 |
| Short-circuit breaking capacity | 50 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Frame family | XT4 |
| Breaking capacity class | S |
| Operating mechanism | Manual switching with automatic protective tripping |
| Application | Low-voltage three-phase electrical distribution |
| Circuit breaker standard | IEC 60947-2 |
The ABB EPX-XT4S-TM0253 is a 25 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits.
The EPX-XT4S-TM0253 has a rated current of 25 A. Circuit selection must account for the connected load, conductor ratings and installation conditions.
The EPX-XT4S-TM0253 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation voltage must be checked against the prospective fault current.
TMA is a thermal-magnetic protection designation associated with adjustable protection functionality. Thermal-magnetic releases use a thermal element for overload protection and a magnetic element for short-circuit protection. The exact adjustment facilities should be confirmed for the supplied device.
Thermal protection responds to sustained overload currents, while magnetic protection provides rapid operation when sufficiently high short-circuit currents occur. Both functions contribute to protecting the electrical circuit.
Yes. The EPX-XT4S-TM0253 has a three-pole (3P) configuration suitable for appropriately designed three-phase electrical distribution applications.
The EPX-XT4S-TM0253 belongs to the ABB Protecta Power Devices range and is associated with the ABB SACE Tmax XT4S circuit breaker family.
The S designation identifies a breaking capacity class within the ABB SACE Tmax XT4 circuit breaker family. The EPX-XT4S-TM0253 has a specified breaking capacity of 50 kA.
Yes. It is suitable for appropriately designed industrial distribution panels and low-voltage switchboards, provided its current rating, breaking capacity, protection characteristics and installation requirements match the application.
No. The specified thermal-magnetic protection uses thermal and magnetic operating principles rather than an electronic LSI protection release.
The ABB order code is 1SDX254958R1. This code identifies the specified EPX-XT4S-TM0253 product within the ABB Protecta Power Devices range.
ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders, contractors and maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT4S-TM0253 combines a 25 A rated current, three-pole configuration and 50 kA breaking capacity with thermal-magnetic protection, making it a practical solution for commercial and industrial electrical distribution applications.