1SDX254955R1 ABB EPX-XT4S-TM0163 16A 3-Pole 50kA MCCB TMA

1SDX254955R1 ABB EPX-XT4S-TM0163 16A 3-Pole 50kA MCCB TMA

ABB EPX-XT4S-TM0163 is a 16 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection. Part of the ABB Protecta Power Devices range, it is designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254955R1Alt SKU: EPX-XT4S-TM0163MPN: 1SDX254955R1
Price
List Price £678.40 ex VAT
Your Price (ex VAT)
£678.40
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £678.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£678.40

Why Choose the ABB EPX-XT4S-TM0163 16A 3-Pole 50kA MCCB?

The ABB EPX-XT4S-TM0163 is a robust 16 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection for commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 50 kA short-circuit breaking capacity with TMA thermal-magnetic protection, making it a practical choice for three-phase circuits requiring a relatively low current rating and substantial fault-interruption capability.

Built around the established ABB SACE Tmax XT4S platform, the EPX-XT4S-TM0163 uses a thermal-magnetic trip unit rather than an electronic protection release. Its TMA protection arrangement combines adjustable thermal overload protection with adjustable magnetic short-circuit protection, providing flexibility when matching protective characteristics to conductor ratings, connected loads and installation requirements.

With its 16 A rated current, three-pole configuration and 50 kA breaking capacity, this MCCB is particularly useful for appropriately designed outgoing circuits within electrical distribution systems where prospective short-circuit currents may be significant. The XT4S platform also offers a 110 mm three-pole device width for integration into compatible ABB Protecta Power distribution assemblies.

The ABB EPX-XT4S-TM0163 is identified by ABB order code 1SDX254955R1, supporting accurate product specification, procurement and replacement.

Key Advantages

  • 16 A rated current for appropriately designed low-current three-phase distribution circuits.
  • Three-pole (3P) configuration for coordinated switching and protection of three-phase circuits.
  • 50 kA short-circuit breaking capacity for installations requiring substantial fault-interruption performance.
  • TMA thermal-magnetic protection combines overload and short-circuit protection in one MCCB.
  • Adjustable thermal overload protection helps match the protective setting to the electrical circuit.
  • Adjustable magnetic short-circuit protection provides flexibility in configuring high-current fault response.
  • Inverse-time thermal operation helps safeguard conductors against sustained overload conditions.
  • Rapid magnetic tripping helps limit the duration of significant short-circuit faults.
  • Mechanical protection technology provides straightforward operation without requiring an electronic trip unit.
  • ABB SACE Tmax XT4S construction combines robust mechanical design with established circuit protection technology.
  • 110 mm three-pole width supports efficient installation in compatible distribution equipment.
  • Three-pole switching enables coordinated disconnection of the three phase conductors.
  • Part of the ABB Protecta Power Devices range for professional low-voltage electrical distribution applications.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4S-TM0163 product designation.
  • 16 A rated current for low-voltage circuit protection.
  • Three-pole (3P) construction for three-phase electrical distribution.
  • 50 kA specified short-circuit breaking capacity.
  • TMA thermal-magnetic trip unit for overload and short-circuit protection.
  • Adjustable thermal protection for sustained overcurrent conditions.
  • Adjustable magnetic protection for high-current short-circuit faults.
  • Inverse-time overload response to help protect conductors against excessive heating.
  • Magnetic short-circuit response for rapid operation during significant faults.
  • ABB SACE Tmax XT4S platform with S short-circuit performance classification.
  • XT4 frame family for commercial and industrial circuit protection.
  • 110 mm three-pole device width for compact distribution assembly installation.
  • Manual switching mechanism with automatic thermal-magnetic protective tripping.
  • Robust moulded case construction suitable for professional electrical distribution environments.
  • Three-phase outgoing circuit protection for appropriately rated conductors and connected loads.
  • Compatible ABB Protecta Power installation using the appropriate mounting and connection components.
  • ABB order code 1SDX254955R1 for accurate product identification.

Advanced Thermal-Magnetic Protection for Three-Phase Power Distribution

The ABB EPX-XT4S-TM0163 provides essential protection for low-voltage electrical distribution circuits where a compact, dependable MCCB with a relatively low current rating is required. Its thermal-magnetic protection system combines an overload-sensitive thermal element with a magnetic element that responds to short-circuit faults. This arrangement helps safeguard electrical conductors, connected equipment and distribution infrastructure against excessive current.

The thermal overload protection responds when current exceeds the selected operating threshold for a sufficient period. Its inverse-time characteristic means that higher overload currents generally produce faster tripping. This helps protect conductors against excessive heating while accommodating normal variations in electrical load within the circuit's design limits.

The adjustable thermal setting allows the protection characteristic to be configured according to the conductor current-carrying capacity and connected equipment requirements. For a 16 A MCCB, correct overload protection selection is particularly important when supplying smaller outgoing circuits from a distribution system with a much higher available fault current.

The magnetic short-circuit protection responds rapidly when fault current reaches the selected magnetic operating threshold. This helps reduce the duration of significant short-circuit faults and the resulting thermal and mechanical stresses on the electrical installation. The TMA configuration provides an adjustable magnetic setting, allowing the fault response to be matched to the requirements of the circuit.

A key advantage of the TMA trip unit is its combination of adjustable thermal and magnetic protection. Unlike a thermal-magnetic configuration with a fixed magnetic threshold, TMA protection provides additional flexibility when selecting the circuit breaker's operating characteristics. This can be beneficial when coordinating protection with connected equipment, provided the settings are selected using the appropriate ABB technical data.

The 50 kA short-circuit breaking capacity is a particularly important feature of the EPX-XT4S-TM0163. Although the circuit breaker has a relatively low 16 A rated current, it is intended for use in appropriately designed electrical systems where the prospective short-circuit current may be substantial. The breaking capacity must be assessed at the relevant operating voltage and compared with the calculated fault level at the point of installation.

The ABB SACE Tmax XT4S platform provides a robust foundation for the device, while its 110 mm three-pole width supports integration into compatible distribution equipment. The three-pole construction allows coordinated switching of the phase conductors, making the circuit breaker suitable for three-phase outgoing circuits and other appropriately designed low-voltage distribution applications.

As part of the ABB Protecta Power range, the EPX-XT4S-TM0163 is intended for installation in compatible panelboards and distribution assemblies using the appropriate mounting and connection components. Electrical designers and installers should verify the prospective fault current, operating voltage, conductor ratings, protective settings and discrimination requirements before commissioning. Correct configuration and installation are essential to achieving the intended protective performance.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible distribution assemblies.
  • Three-phase outgoing circuit protection.
  • Industrial switchboards and sub-distribution panels.
  • Manufacturing and production facilities.
  • Commercial offices and business premises.
  • Retail buildings and hospitality facilities.
  • Warehouses and logistics centres.
  • Building services and mechanical plant electrical distribution.
  • Lower-current three-phase feeder circuits with appropriately rated conductors.
  • Distribution circuits requiring adjustable thermal overload protection.
  • Installations requiring adjustable magnetic short-circuit protection.
  • Electrical systems requiring a 50 kA breaking-capacity MCCB.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Product range Protecta Power
Circuit breaker platform ABB SACE Tmax XT4S
ABB order code 1SDX254955R1
Product type Moulded case circuit breaker (MCCB)
Rated current 16 A
Number of poles 3
Electrical configuration Three-phase
Short-circuit breaking capacity 50 kA
Trip unit designation TMA
Protection technology Thermal-magnetic
Thermal overload protection Adjustable
Magnetic short-circuit protection Adjustable
Overload protection principle Thermal inverse-time operation
Short-circuit protection principle Magnetic instantaneous operation
Frame family XT4
Frame performance designation S
Device width 110 mm
Operating mechanism Manual switching with automatic thermal-magnetic tripping
Applicable circuit breaker standard IEC 60947-2
Application category Low-voltage electrical power distribution
Mounting application Compatible electrical distribution assemblies
Typical installation ABB Protecta Power panelboards and compatible distribution equipment
Installation requirements Confirm operating voltage, prospective fault current, conductor ratings, protection settings and assembly compatibility before installation
Protection setting verification Confirm the exact thermal and magnetic adjustment ranges against the ABB technical documentation for the supplied device

Frequently Asked Questions

What is the ABB EPX-XT4S-TM0163 used for?

The ABB EPX-XT4S-TM0163 is a three-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT4S-TM0163?

The circuit breaker has a rated current of 16 A. Its TMA thermal-magnetic trip unit provides adjustable overload and short-circuit protection characteristics, allowing the protective settings to be configured for the electrical circuit.

What is the breaking capacity of this MCCB?

The ABB EPX-XT4S-TM0163 has a specified 50 kA short-circuit breaking capacity. Its suitability must be assessed against the installation's prospective fault current, operating voltage and applicable electrical protection requirements.

What does TMA mean on the ABB XT4S circuit breaker?

TMA refers to a thermal-magnetic trip unit with adjustable thermal overload protection and adjustable magnetic short-circuit protection. The thermal element responds to sustained overloads, while the magnetic element provides rapid operation during high-current short-circuit faults.

What is the difference between TMA and TMD protection?

Both TMA and TMD are thermal-magnetic protection arrangements. A TMA trip unit provides adjustable thermal and magnetic protection thresholds, while a TMD trip unit typically combines an adjustable thermal threshold with a fixed magnetic threshold. TMA therefore offers additional flexibility when configuring short-circuit protection characteristics.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection engineering with practical low-voltage distribution solutions. The EPX-XT4S-TM0163 offers a robust 16 A, three-pole XT4S MCCB configuration with adjustable TMA thermal-magnetic protection and a 50 kA breaking capacity, supporting dependable circuit protection in appropriately designed commercial and industrial electrical installations.