1SDX254945R1 ABB EPX-XT2S-TM1253 125A 3-Pole 50kA TMA MCCB

1SDX254945R1 ABB EPX-XT2S-TM1253 125A 3-Pole 50kA TMA MCCB

ABB EPX-XT2S-TM1253 is a 125 A three-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA breaking capacity at 415 V AC and adjustable TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX254945R1Alt SKU: EPX-XT2S-TM1253MPN: 1SDX254945R1
Price
List Price £554.49 ex VAT
Your Price (ex VAT)
£554.49
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £554.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£554.49

Why Choose the ABB EPX-XT2S-TM1253 125A 3-Pole 50kA MCCB?

The ABB EPX-XT2S-TM1253 is a high-performance 125 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT2S160 platform, offering robust electrical protection for commercial buildings, industrial facilities and power distribution infrastructure.

Featuring an ABB TMA thermal-magnetic trip unit, the EPX-XT2S-TM1253 combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid fault interruption when short-circuit currents exceed the selected threshold. These protection functions help safeguard electrical cables, switchgear and connected equipment while allowing protection settings to be matched to the installation.

With a 125 A rated current, three-pole construction and 50 kA rated ultimate short-circuit breaking capacity at 415 V AC, this MCCB is suitable for three-phase electrical distribution applications requiring substantial fault-interruption capability. Its compact XT2S160 frame, fixed-mounted construction and front terminal arrangement support integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • 125 A rated current for commercial and industrial electrical distribution circuits.
  • Three-pole configuration suitable for three-phase low-voltage electrical systems.
  • 50 kA breaking capacity at 415 V AC provides substantial short-circuit fault-interruption capability.
  • ABB TMA thermal-magnetic trip unit combines adjustable overload and short-circuit protection.
  • Adjustable thermal protection helps protect electrical cables and connected equipment against sustained excessive current.
  • Adjustable magnetic protection enables short-circuit trip settings to be selected according to circuit requirements.
  • Thermal adjustment range of 87.5–125 A provides flexibility for overload protection settings.
  • Magnetic adjustment range of 625–1250 A supports short-circuit protection configuration.
  • ABB Tmax XT2S160 frame combines compact construction with robust electrical performance.
  • 90 mm three-pole width supports efficient use of switchboard space.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT2S160 moulded case circuit breaker platform.
  • 125 A rated current.
  • Three-pole (3P) construction.
  • 50 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • TMA thermal-magnetic trip unit.
  • Adjustable thermal overload protection from 87.5–125 A.
  • Adjustable magnetic short-circuit protection from 625–1250 A.
  • XT2S160 frame with a maximum frame rating of 160 A.
  • 90 mm three-pole frame width for compact electrical distribution assemblies.
  • Fixed-mounted construction for suitable distribution board and switchgear installations.
  • Front terminal connections for electrical conductor termination.
  • Manual toggle operating mechanism with trip indication and reset capability.
  • Three-pole switching and protection for three-phase electrical circuits.
  • Designed for low-voltage electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT2 installation accessories.

Adjustable Thermal-Magnetic Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT2S-TM1253 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Its TMA thermal-magnetic trip unit provides adjustable thermal protection against sustained overcurrent and adjustable magnetic protection against short-circuit faults. The thermal setting range of 87.5–125 A and magnetic setting range of 625–1250 A allow the protection characteristics to be configured according to the electrical circuit and coordination requirements.

The ABB SACE Tmax XT2 circuit breaker family is engineered for dependable protection in modern low-voltage distribution assemblies. The EPX-XT2S-TM1253 is particularly suitable for installations requiring 125 A three-pole circuit protection and a 50 kA short-circuit breaking rating at 415 V AC. Circuit breaker selection should consider operating voltage, prospective fault current, conductor characteristics, load requirements and protective device coordination. Where the MCCB supplies a motor circuit, dedicated motor overload protection may also be necessary depending on the installation design.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Main and sub-distribution switchboards.
  • Industrial machinery supply circuits and electrical feeders.
  • Manufacturing facilities and industrial workshops.
  • Building services and commercial electrical infrastructure.
  • Warehouses, logistics centres and production facilities.
  • Industrial control panels requiring adjustable thermal-magnetic protection.
  • Electrical distribution circuits requiring high short-circuit breaking capacity.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT2S160
ABB order code 1SDX254945R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 125 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 50 kA at 415 V AC
Trip unit TMA
Trip unit technology Thermal-magnetic
Thermal overload protection setting 87.5–125 A
Thermal adjustment 0.7–1 × In
Magnetic short-circuit protection setting 625–1250 A
Magnetic adjustment 5–10 × In
Protection functions Adjustable thermal overload and magnetic short-circuit protection
Frame family XT2S160
Maximum frame rating 160 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Three-pole frame width 90 mm
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual toggle operation
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-TM1253 used for?

The ABB EPX-XT2S-TM1253 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial three-phase electrical installations.

What is the rated current of the EPX-XT2S-TM1253?

The circuit breaker has a 125 A rated current and uses the ABB Tmax XT2S160 frame, which has a maximum frame rating of 160 A. Its adjustable thermal protection setting ranges from 87.5–125 A.

What is the breaking capacity of the ABB EPX-XT2S-TM1253?

The EPX-XT2S-TM1253 has a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current before selection.

What protection does the TMA thermal-magnetic trip unit provide?

The ABB TMA thermal-magnetic trip unit provides adjustable thermal overload protection and adjustable magnetic short-circuit protection. For this 125 A configuration, the thermal adjustment range is 87.5–125 A, while the magnetic adjustment range is 625–1250 A.

Where is the ABB EPX-XT2S-TM1253 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies. Its fixed-mounted construction, front terminal connections and compact 90 mm three-pole width support integration into suitable electrical distribution panels.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT2S-TM1253 combines a 125 A rating, three-pole construction, 50 kA breaking capacity at 415 V AC and adjustable TMA thermal-magnetic protection in a compact solution for commercial, industrial and infrastructure power distribution applications.