ABB EPX-XT2S-TM1003 is a Protecta Power Devices XT2S 100 A three-pole moulded case circuit breaker featuring a specified 50 kA breaking capacity and TMA thermal-magnetic trip unit for compatible low-voltage electrical distribution applications.
£461.03
The ABB EPX-XT2S-TM1003 is a 100 A, three-pole moulded case circuit breaker (MCCB) from the ABB Protecta Power Devices range. Featuring the XT2S circuit-breaker configuration, a specified 50 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this device is designed for compatible low-voltage electrical distribution systems requiring overload and short-circuit protection.
The ABB XT2S 100 A 3P MCCB combines three-pole circuit protection with thermal-magnetic tripping technology. Its thermal protection function responds to sustained overload conditions, while its magnetic protection function responds to high short-circuit currents. Together, these protection principles help safeguard electrical conductors and connected equipment when the circuit breaker is correctly selected, coordinated and installed.
Identified by ABB order code 1SDX254943R1, the EPX-XT2S-TM1003 provides a manufacturer-specified combination of 100 A rated current, three-pole construction, 50 kA breaking capacity and TMA protection. It is suitable for appropriately engineered electrical distribution boards, industrial switchboards and commercial power distribution assemblies.
Moulded case circuit breakers are important components of low-voltage electrical distribution systems, providing circuit switching and protection against excessive current. Thermal-magnetic MCCBs combine two complementary protection mechanisms: a thermal element that responds to sustained overloads and a magnetic element that reacts rapidly to sufficiently high short-circuit currents.
The ABB EPX-XT2S-TM1003 provides these protection functions in a 100 A, three-pole XT2S configuration. Its TMA trip unit supports thermal-magnetic overcurrent protection, while the specified 50 kA breaking capacity makes it relevant to installations requiring a circuit breaker with substantial fault interruption capability.
The specified 50 kA breaking capacity must be evaluated at the applicable operating voltage and under the manufacturer's relevant test conditions. Exact Icu and Ics ratings, rated operational voltage, trip adjustment ranges, mounting arrangements and terminal configurations should be confirmed using the appropriate ABB technical documentation. Proper selection also requires consideration of prospective fault current, conductor protection, discrimination and the overall electrical installation design.
The ABB EPX-XT2S-TM1003 is a 100 A, three-pole moulded case circuit breaker featuring an XT2S configuration, a specified 50 kA breaking capacity and a TMA thermal-magnetic trip unit. It belongs to the ABB Protecta Power Devices range.
The EPX-XT2S-TM1003 has a rated current of 100 A and a three-pole (3P) configuration, making it suitable for appropriately designed three-phase electrical distribution circuits.
The specified 50 kA breaking capacity identifies the circuit breaker's short-circuit interruption capability under the applicable manufacturer-defined conditions. The relevant operational voltage and Icu/Ics ratings must be verified against ABB documentation before installation.
TMA identifies a thermal-magnetic trip unit. Thermal protection responds to sustained overload conditions, while magnetic protection responds to short-circuit faults. The exact trip characteristics and adjustment settings depend on the specific ABB configuration.
The EPX-XT2S-TM1003 is an XT2S 100 A MCCB, while the EPX-XT1S-TM1253 is an XT1S 125 A MCCB. Both are specified as three-pole devices with 50 kA breaking capacity and TMA thermal-magnetic protection. They are different configurations and should not be treated as interchangeable without confirming their electrical and mechanical compatibility.
ABB Protecta Power Devices support professional electrical engineers, contractors and switchboard manufacturers with dedicated low-voltage circuit protection equipment. The EPX-XT2S-TM1003 combines a 100 A three-pole XT2S MCCB configuration, 50 kA specified breaking capacity and TMA thermal-magnetic protection for compatible industrial and commercial electrical distribution applications.