1SDX254942R1 ABB EPX-XT2S-TM0803 80A 3-Pole 50kA TMA Moulded Case Circuit Breaker

1SDX254942R1 ABB EPX-XT2S-TM0803 80A 3-Pole 50kA TMA Moulded Case Circuit Breaker

ABB EPX-XT2S-TM0803 is an 80 A three-pole moulded case circuit breaker with 50 kA breaking capacity at 380–415 V AC and an adjustable TMA thermal-magnetic trip unit providing overload and instantaneous short-circuit protection for low-voltage electrical distribution.

SKU: 1SDX254942R1Alt SKU: EPX-XT2S-TM0803MPN: 1SDX254942R1
Price
List Price £461.03 ex VAT
Your Price (ex VAT)
£461.03
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £461.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£461.03

Why Choose the ABB EPX-XT2S-TM0803 80A 3-Pole MCCB?

The ABB EPX-XT2S-TM0803 is a 80 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 50 kA breaking capacity at 380–415 V AC and an adjustable TMA thermal-magnetic trip unit, this circuit breaker is suitable for commercial, industrial and infrastructure installations requiring dependable circuit protection.

Part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0803 incorporates proven ABB SACE Tmax XT2S technology. Its TMA trip unit combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. Unlike electronic trip units, the thermal-magnetic release uses thermal and electromagnetic operating principles to detect and respond to overcurrent conditions.

With an 80 A rated current, three-pole configuration and 50 kA short-circuit breaking capacity, the EPX-XT2S-TM0803 provides effective protection for three-phase distribution circuits. Its XT2S 160 frame, fixed-mounted construction and front connection terminals make it a practical solution for electrical panel builders, contractors and maintenance engineers working with compatible ABB Protecta Power distribution assemblies.

Key Advantages

  • 80 A rated current suitable for commercial and industrial low-voltage distribution circuits.
  • 50 kA breaking capacity at 380–415 V AC provides robust short-circuit protection.
  • Three-pole configuration supports three-phase electrical distribution applications.
  • Adjustable TMA thermal-magnetic trip unit combines overload and short-circuit protection.
  • Adjustable thermal protection allows the overload threshold to be configured between 56 A and 80 A.
  • Adjustable magnetic protection provides an instantaneous short-circuit trip setting between 400 A and 800 A.
  • Thermal-magnetic operating principle provides circuit protection without requiring an electronic protection release.
  • ABB SACE Tmax XT2S construction combines dependable switching performance with a compact frame.
  • Fixed-mounted design with front terminals supports installation in suitable electrical distribution assemblies.
  • Protecta Power integration makes the breaker suitable for compatible ABB distribution board configurations.
  • Adjustable protection settings help engineers match the breaker characteristics to connected conductors and equipment.

Key Features

  • ABB EPX-XT2S-TM0803 moulded case circuit breaker.
  • 80 A rated current.
  • Three-pole (3P) configuration.
  • 50 kA rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC.
  • ABB SACE Tmax XT2S 160 frame.
  • TMA adjustable thermal-magnetic protection release.
  • Thermal overload protection adjustment: 56–80 A.
  • Magnetic short-circuit protection adjustment: 400–800 A.
  • Thermal adjustment range: 0.7–1 × In.
  • Magnetic adjustment range: 5–10 × In.
  • Inverse-time thermal overload response for sustained overcurrent conditions.
  • Instantaneous magnetic protection for short-circuit faults.
  • Fixed installation with front connection terminals.
  • Manual operating mechanism with automatic tripping under fault conditions.
  • Rated operational voltage up to 690 V AC.
  • Designed for low-voltage AC power distribution and circuit protection.
  • Compatible with appropriately selected ABB Tmax XT accessories and distribution equipment.

Adjustable Thermal-Magnetic Protection for Three-Phase Distribution

The ABB EPX-XT2S-TM0803 uses a TMA thermal-magnetic trip unit to provide two complementary protection functions. The thermal element responds to sustained overload currents through an inverse-time operating characteristic, while the magnetic element provides instantaneous tripping when a sufficiently high short-circuit current occurs. The thermal setting can be adjusted from 56 A to 80 A, while the magnetic setting can be adjusted from 400 A to 800 A. These adjustment ranges allow engineers to configure protection according to the requirements of the installation.

The ABB SACE Tmax XT2S 160 platform combines a compact circuit breaker frame with robust fault interruption capabilities. The EPX-XT2S-TM0803 provides a 50 kA ultimate breaking capacity at 380–415 V AC, making it suitable for appropriately designed distribution systems with significant prospective fault currents. Its three-pole construction, fixed mounting arrangement and front terminals support installation in compatible electrical panels, switchboards and ABB Protecta Power distribution assemblies.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution systems requiring three-pole protection.
  • 80 A electrical distribution feeders and outgoing circuits.
  • Secondary distribution panels in commercial buildings.
  • Industrial machinery and equipment supply circuits.
  • Manufacturing and production facilities.
  • Warehouses, logistics centres and industrial infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Distribution circuits requiring adjustable thermal overload protection.
  • Installations requiring adjustable instantaneous magnetic short-circuit protection.
  • Electrical maintenance, refurbishment and distribution board upgrades.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT2S
ABB order code 1SDX254942R1
ABB base circuit breaker reference 1SDA067557R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 80 A
Rated uninterrupted current (Iu) 80 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 380–415 V AC
Rated ultimate breaking capacity at 220–230 V AC 85 kA
Rated ultimate breaking capacity at 440 V AC 50 kA
Rated ultimate breaking capacity at 500 V AC 36 kA
Rated ultimate breaking capacity at 690 V AC 12 kA
Trip unit TMA
Release type Adjustable thermal-magnetic
Thermal protection function Adjustable overload protection
Thermal adjustment range 0.7–1 × In
Thermal current setting range 56–80 A
Magnetic protection function Adjustable instantaneous short-circuit protection
Magnetic adjustment range 5–10 × In
Magnetic trip current setting range 400–800 A
Frame size XT2
Frame designation XT2S 160
Frame maximum current rating 160 A
Breaking capacity class S
Rated operational voltage (Ue) Up to 690 V AC
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Operating mechanism Manual toggle
Application Low-voltage three-phase electrical distribution
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0803 used for?

The ABB EPX-XT2S-TM0803 is an 80 A three-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT2S-TM0803?

The circuit breaker has a rated current of 80 A and uses an ABB SACE Tmax XT2S 160 frame with an 80 A adjustable TMA thermal-magnetic protection release.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2S-TM0803 has a 50 kA rated ultimate short-circuit breaking capacity at 380–415 V AC. Its breaking capacity varies with operating voltage, so the applicable rating must be checked against the prospective fault current of the installation.

What does TMA mean on the ABB EPX-XT2S-TM0803?

TMA identifies an adjustable thermal-magnetic trip unit. It combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection.

What is the thermal overload adjustment range?

The TMA release provides an adjustable thermal overload setting from 0.7 to 1 × In. For this 80 A circuit breaker, the adjustment range is 56–80 A.

What is the magnetic short-circuit adjustment range?

The instantaneous magnetic protection setting can be adjusted between 5 and 10 × In, corresponding to 400–800 A for the 80 A TMA release.

What is the difference between TMA and TMD trip units?

A TMA trip unit provides adjustable thermal overload protection and adjustable magnetic short-circuit protection. A TMD trip unit provides thermal-magnetic protection but generally uses a fixed magnetic threshold for the relevant configurations. The available settings depend on the particular ABB circuit breaker and release.

Is the ABB EPX-XT2S-TM0803 a three-pole circuit breaker?

Yes. The EPX-XT2S-TM0803 is a three-pole (3P) MCCB designed for three-phase electrical distribution applications requiring three-pole switching and circuit protection.

What ABB circuit breaker series does this model belong to?

The EPX-XT2S-TM0803 belongs to the ABB Protecta Power Devices range and uses ABB SACE Tmax XT2S 160 technology. The corresponding ABB base circuit breaker reference is 1SDA067557R1.

What is the difference between XT2S and XT2N circuit breakers?

XT2S and XT2N identify different breaking capacity classes within the ABB SACE Tmax XT2 family. The XT2S version offers a higher short-circuit breaking capacity than the corresponding XT2N version under comparable rated conditions. The EPX-XT2S-TM0803 has a 50 kA breaking capacity at 380–415 V AC.

Where is the ABB EPX-XT2S-TM0803 typically installed?

This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems. Its fixed-mounted construction and front terminals support integration into suitable electrical enclosures.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT2S-TM0803 combines an 80 A rated current, three-pole configuration and 50 kA breaking capacity with adjustable TMA thermal-magnetic protection, making it a practical choice for reliable three-phase low-voltage electrical distribution.