ABB EPX-XT2S-TM0633 is a 63 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring adjustable TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX254940R1Alt SKU: EPX-XT2S-TM0633MPN: 1SDX254940R1
Price
List Price £451.41 ex VAT
Your Price (ex VAT)
£451.41
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £451.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£451.41

Why Choose the ABB EPX-XT2S-TM0633 63A 3-Pole 50kA MCCB?

The ABB EPX-XT2S-TM0633 is a high-performance 63 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S 160 A frame platform, combining compact construction, thermal-magnetic protection and high short-circuit interruption capability.

Equipped with an ABB TMA thermal-magnetic trip unit, the EPX-XT2S-TM0633 provides adjustable thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect cables and connected equipment against overheating. The magnetic element provides rapid tripping when short-circuit current reaches its configured threshold, helping reduce the consequences of electrical faults.

With a rated current of 63 A, a three-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for protecting three-phase outgoing circuits in commercial and industrial distribution systems. Its compact 90 mm-wide XT2 frame supports integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, panel builders and maintenance engineers.

Key Advantages

  • 63 A rated current: Suitable for protecting appropriately designed low-voltage electrical distribution circuits.
  • Three-pole construction: Provides coordinated switching and protection of three phase conductors.
  • 50 kA breaking capacity: Offers substantial short-circuit interruption capability at the applicable rated operating voltage.
  • ABB TMA thermal-magnetic protection: Combines overload and short-circuit protection within one compact circuit breaker.
  • Adjustable thermal protection: Allows the overload protection threshold to be matched to suitable circuit requirements.
  • Adjustable magnetic protection: Enables selection of magnetic short-circuit trip characteristics within the manufacturer's specified range.
  • Rapid fault interruption: Magnetic tripping responds to high-current short-circuit conditions.
  • Independent protection operation: Thermal-magnetic protection does not require an external auxiliary power supply.
  • ABB Tmax XT2S platform: Uses established ABB circuit breaker technology for dependable electrical protection.
  • Compact 90 mm construction: Helps conserve installation space in compatible distribution assemblies.
  • Protecta Power integration: Designed for appropriately configured ABB Protecta Power distribution boards.
  • Robust moulded case design: Suitable for commercial and industrial electrical distribution environments.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Circuit breaker series: ABB SACE Tmax XT2.
  • Frame designation: XT2S.
  • Rated current: 63 A.
  • Number of poles: 3.
  • Specified short-circuit breaking capacity: 50 kA.
  • Trip unit: ABB TMA thermal-magnetic.
  • Thermal protection: Adjustable overload protection.
  • Magnetic protection: Adjustable short-circuit protection.
  • XT2 frame current class: 160 A.
  • Thermal adjustment range: Approximately 44.1–63 A for the corresponding XT2S TMA 63 A configuration.
  • Magnetic adjustment range: 315–630 A for the corresponding XT2S TMA 63 A configuration.
  • Three-pole switching: Coordinated operation of three phase conductors.
  • Nominal device width: 90 mm.
  • Operating mechanism: Manual front-operated toggle mechanism.
  • Trip indication: Mechanical indication of the tripped condition.
  • Accessory compatibility: Supports appropriately selected ABB Tmax XT2 accessories and mounting components.
  • Product family standard: IEC/EN 60947-2.

Reliable TMA Thermal-Magnetic Protection for Electrical Distribution

The ABB EPX-XT2S-TM0633 uses thermal and magnetic trip mechanisms to protect electrical circuits against abnormal current conditions. The thermal protection element responds to sustained overloads, helping prevent excessive heating of conductors and connected equipment. The magnetic protection element responds rapidly when short-circuit current reaches its configured threshold, allowing the breaker to interrupt the circuit and reduce the potential for damage caused by electrical faults.

The ABB TMA trip unit provides adjustable protection characteristics. For the corresponding ABB XT2S TMA 63 A configuration, the thermal protection setting is adjustable from approximately 44.1–63 A, while the magnetic protection setting covers 315–630 A. These adjustments allow electrical engineers to select suitable protection characteristics for conductor capacity, connected equipment and expected fault conditions. The settings available on the supplied device should be confirmed before commissioning.

The ABB SACE Tmax XT2S platform combines thermal-magnetic protection with compact moulded case construction and substantial short-circuit performance. The specified 50 kA breaking capacity makes this circuit breaker suitable for appropriately designed circuits where higher fault interruption capability is required. Its three-pole configuration supports three-phase distribution applications, while the XT2 frame enables integration into compatible ABB Protecta Power distribution boards and electrical switchgear assemblies.

Typical Applications

  • ABB Protecta Power distribution boards: Protection of compatible three-phase outgoing circuits.
  • Commercial electrical distribution: Circuit protection in offices, retail premises and commercial buildings.
  • Industrial switchboards: Protection of suitably rated three-phase distribution feeders.
  • Sub-distribution boards: Overload and short-circuit protection for outgoing electrical circuits.
  • Electrical control panels: Protection of appropriately designed three-phase equipment supply circuits.
  • Building services: Electrical protection for ventilation, heating, cooling and mechanical plant installations.
  • Industrial machinery supplies: Feeder protection where thermal-magnetic trip characteristics are suitable for the connected equipment.
  • Warehouses and manufacturing facilities: Protection of low-voltage electrical distribution circuits.
  • High-fault-level installations: Circuits requiring 50 kA short-circuit breaking capability at the applicable operating voltage.
  • Electrical panel building: Distribution assemblies incorporating the ABB SACE Tmax XT2 circuit breaker platform.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT2
Product model EPX-XT2S-TM0633
ABB order code 1SDX254940R1
Corresponding ABB circuit breaker reference 1SDA067556R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT2S 160
Frame current class 160 A
Rated current (In) 63 A
Number of poles 3
Specified short-circuit breaking capacity 50 kA
Rated ultimate short-circuit breaking capacity (Icu), corresponding XT2S configuration 50 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics), corresponding XT2S configuration 50 kA at 415 V AC
Trip unit technology Thermal-magnetic
Trip unit designation TMA
Overload protection Adjustable thermal trip
Short-circuit protection Adjustable magnetic trip
Thermal adjustment range, corresponding XT2S TMA 63 A configuration 44.1–63 A
Magnetic adjustment range, corresponding XT2S TMA 63 A configuration 315–630 A
Rated operational voltage (Ue), XT2S series Up to 690 V AC
Rated insulation voltage (Ui), XT2S series 1000 V
Rated impulse withstand voltage (Uimp), XT2S series 8 kV
Electrical system Low-voltage AC distribution
Phase configuration Three-phase
Nominal device width 90 mm
Operating mechanism Manual toggle operation
Primary function Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0633 used for?

The ABB EPX-XT2S-TM0633 is a 63 A three-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.

What is the rated current of the EPX-XT2S-TM0633?

The EPX-XT2S-TM0633 has a 63 A rated current and uses the ABB SACE Tmax XT2S 160 A frame platform. The 160 A designation identifies the current class of the breaker frame rather than the rated current of this individual device.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2S-TM0633 has a specified 50 kA short-circuit breaking capacity. The corresponding ABB XT2S configuration provides a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC. The prospective fault current and applicable operating voltage must be verified when selecting the circuit breaker.

What does TMA thermal-magnetic protection mean?

TMA identifies a thermal-magnetic trip unit providing adjustable thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element enables rapid tripping during short-circuit conditions.

Can the overload and short-circuit settings be adjusted?

Yes. The corresponding ABB XT2S TMA 63 A configuration provides a thermal adjustment range of approximately 44.1–63 A and a magnetic adjustment range of 315–630 A. Settings should be confirmed against the supplied device and selected according to conductor ratings, connected loads and installation protection requirements.

What is the difference between ABB XT2N and XT2S circuit breakers?

XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding ABB Protecta Power XT2N devices are specified at 36 kA, while XT2S versions are specified at 50 kA. The correct version should be selected according to the prospective fault current and applicable operating voltage.

Is the EPX-XT2S-TM0633 suitable for three-phase electrical systems?

Yes. The EPX-XT2S-TM0633 has a three-pole configuration designed for switching and protecting three phase conductors. It is suitable for appropriately designed three-phase low-voltage distribution circuits where neutral switching through the breaker is not required.

Can the EPX-XT2S-TM0633 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2S-TM0633 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection settings should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, adjustable thermal-magnetic protection and dependable short-circuit interruption capability for modern low-voltage power systems.