ABB EPX-XT2S-TM0633 is a 63 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring adjustable TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.
£451.41
The ABB EPX-XT2S-TM0633 is a high-performance 63 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT2S 160 A frame platform, combining compact construction, thermal-magnetic protection and high short-circuit interruption capability.
Equipped with an ABB TMA thermal-magnetic trip unit, the EPX-XT2S-TM0633 provides adjustable thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect cables and connected equipment against overheating. The magnetic element provides rapid tripping when short-circuit current reaches its configured threshold, helping reduce the consequences of electrical faults.
With a rated current of 63 A, a three-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for protecting three-phase outgoing circuits in commercial and industrial distribution systems. Its compact 90 mm-wide XT2 frame supports integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, panel builders and maintenance engineers.
The ABB EPX-XT2S-TM0633 uses thermal and magnetic trip mechanisms to protect electrical circuits against abnormal current conditions. The thermal protection element responds to sustained overloads, helping prevent excessive heating of conductors and connected equipment. The magnetic protection element responds rapidly when short-circuit current reaches its configured threshold, allowing the breaker to interrupt the circuit and reduce the potential for damage caused by electrical faults.
The ABB TMA trip unit provides adjustable protection characteristics. For the corresponding ABB XT2S TMA 63 A configuration, the thermal protection setting is adjustable from approximately 44.1–63 A, while the magnetic protection setting covers 315–630 A. These adjustments allow electrical engineers to select suitable protection characteristics for conductor capacity, connected equipment and expected fault conditions. The settings available on the supplied device should be confirmed before commissioning.
The ABB SACE Tmax XT2S platform combines thermal-magnetic protection with compact moulded case construction and substantial short-circuit performance. The specified 50 kA breaking capacity makes this circuit breaker suitable for appropriately designed circuits where higher fault interruption capability is required. Its three-pole configuration supports three-phase distribution applications, while the XT2 frame enables integration into compatible ABB Protecta Power distribution boards and electrical switchgear assemblies.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT2 |
| Product model | EPX-XT2S-TM0633 |
| ABB order code | 1SDX254940R1 |
| Corresponding ABB circuit breaker reference | 1SDA067556R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT2S 160 |
| Frame current class | 160 A |
| Rated current (In) | 63 A |
| Number of poles | 3 |
| Specified short-circuit breaking capacity | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu), corresponding XT2S configuration | 50 kA at 415 V AC |
| Rated service short-circuit breaking capacity (Ics), corresponding XT2S configuration | 50 kA at 415 V AC |
| Trip unit technology | Thermal-magnetic |
| Trip unit designation | TMA |
| Overload protection | Adjustable thermal trip |
| Short-circuit protection | Adjustable magnetic trip |
| Thermal adjustment range, corresponding XT2S TMA 63 A configuration | 44.1–63 A |
| Magnetic adjustment range, corresponding XT2S TMA 63 A configuration | 315–630 A |
| Rated operational voltage (Ue), XT2S series | Up to 690 V AC |
| Rated insulation voltage (Ui), XT2S series | 1000 V |
| Rated impulse withstand voltage (Uimp), XT2S series | 8 kV |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase |
| Nominal device width | 90 mm |
| Operating mechanism | Manual toggle operation |
| Primary function | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT2S-TM0633 is a 63 A three-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT2S-TM0633 has a 63 A rated current and uses the ABB SACE Tmax XT2S 160 A frame platform. The 160 A designation identifies the current class of the breaker frame rather than the rated current of this individual device.
The EPX-XT2S-TM0633 has a specified 50 kA short-circuit breaking capacity. The corresponding ABB XT2S configuration provides a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC. The prospective fault current and applicable operating voltage must be verified when selecting the circuit breaker.
TMA identifies a thermal-magnetic trip unit providing adjustable thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element enables rapid tripping during short-circuit conditions.
Yes. The corresponding ABB XT2S TMA 63 A configuration provides a thermal adjustment range of approximately 44.1–63 A and a magnetic adjustment range of 315–630 A. Settings should be confirmed against the supplied device and selected according to conductor ratings, connected loads and installation protection requirements.
XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding ABB Protecta Power XT2N devices are specified at 36 kA, while XT2S versions are specified at 50 kA. The correct version should be selected according to the prospective fault current and applicable operating voltage.
Yes. The EPX-XT2S-TM0633 has a three-pole configuration designed for switching and protecting three phase conductors. It is suitable for appropriately designed three-phase low-voltage distribution circuits where neutral switching through the breaker is not required.
Yes. The EPX-XT2S-TM0633 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection settings should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, adjustable thermal-magnetic protection and dependable short-circuit interruption capability for modern low-voltage power systems.