ABB EPX-XT2S-TM0503 is a 50 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring TMA adjustable thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.
£451.41
The ABB EPX-XT2S-TM0503 is a high-performance 50 A three-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT2S platform, combining compact construction, thermal-magnetic protection technology and substantial fault interruption capability for commercial and industrial installations.
Featuring an ABB TMA thermal-magnetic trip unit, the EPX-XT2S-TM0503 provides adjustable thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, helping protect cables and connected equipment against overheating, while the magnetic element provides rapid interruption during short-circuit conditions. This conventional protection technology offers dependable operation without requiring an electronic trip unit or external auxiliary power supply.
With a rated current of 50 A, a three-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is suitable for protecting three-phase outgoing circuits in electrical distribution systems with significant prospective fault currents. Its compact 90 mm-wide XT2 frame supports integration into compatible ABB Protecta Power distribution boards, making it a practical choice for electrical contractors, panel builders and maintenance engineers.
The ABB EPX-XT2S-TM0503 uses thermal and magnetic trip mechanisms to protect electrical circuits against abnormal current conditions. The thermal protection element responds to sustained overloads, helping prevent excessive heating of conductors and connected equipment. The magnetic protection element responds rapidly when short-circuit current reaches its configured threshold, allowing the breaker to interrupt the circuit and limit the consequences of electrical faults.
The ABB TMA trip unit offers adjustable protection characteristics for the corresponding XT2S 50 A breaker configuration. The thermal protection setting can be selected within the 35–50 A range, while the magnetic trip setting can be adjusted within the 250–500 A range. These adjustments help electrical engineers match circuit protection to conductor capacity, connected loads and fault conditions. Final settings should always be confirmed against the exact supplied breaker and the installation design.
The ABB SACE Tmax XT2S platform combines this protection technology with compact moulded case construction and a high short-circuit performance class. Its specified 50 kA breaking capacity makes it particularly useful for circuits where the prospective short-circuit current exceeds the capability of lower-rated protective devices. The three-pole design is suitable for three-phase circuits, while the compact XT2 frame facilitates installation in compatible ABB Protecta Power distribution boards and switchgear assemblies.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT2 |
| Product model | EPX-XT2S-TM0503 |
| ABB order code | 1SDX254938R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT2S |
| Frame current class | 160 A |
| Rated current (In) | 50 A |
| Number of poles | 3 |
| Specified short-circuit breaking capacity | 50 kA |
| XT2S series rated ultimate short-circuit breaking capacity (Icu) | 50 kA at 415 V AC |
| XT2S series rated service short-circuit breaking capacity (Ics) | 50 kA at 415 V AC |
| Trip unit technology | Thermal-magnetic |
| Trip unit designation | TMA |
| Overload protection | Adjustable thermal trip |
| Short-circuit protection | Adjustable magnetic trip |
| Thermal adjustment range, corresponding XT2S TMA 50 A configuration | 35–50 A |
| Magnetic adjustment range, corresponding XT2S TMA 50 A configuration | 250–500 A |
| Rated operational voltage (Ue), XT2S series | Up to 690 V AC |
| Rated insulation voltage (Ui), XT2S series | 1000 V |
| Rated impulse withstand voltage (Uimp), XT2S series | 8 kV |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase |
| Nominal device width | 90 mm |
| Operating mechanism | Manual toggle operation |
| Primary function | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT2S-TM0503 is a 50 A three-pole thermal-magnetic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.
The EPX-XT2S-TM0503 has a 50 A rated current and uses the ABB SACE Tmax XT2S 160 A frame platform. The 160 A frame designation identifies the current class of the breaker platform rather than the rated current of this individual device.
The EPX-XT2S-TM0503 has a specified 50 kA short-circuit breaking capacity. The ABB XT2S series provides a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC for the corresponding configuration. The prospective fault current and operating voltage must be verified when selecting the circuit breaker.
TMA identifies a thermal-magnetic trip unit providing adjustable thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element enables rapid tripping during short-circuit conditions.
Yes. The corresponding ABB XT2S TMA 50 A configuration provides a thermal adjustment range of 35–50 A and a magnetic adjustment range of 250–500 A. The applicable settings should be confirmed for the supplied breaker and selected according to the electrical installation's protection requirements.
XT2N and XT2S identify different short-circuit performance versions within the ABB SACE Tmax XT2 family. The corresponding Protecta Power XT2N devices are specified at 36 kA, while XT2S versions provide 50 kA. The appropriate version should be selected according to the prospective fault current and applicable operating voltage.
Yes. The EPX-XT2S-TM0503 has a three-pole configuration for switching and protecting three phase conductors. It is suitable for appropriately designed three-phase low-voltage distribution circuits where neutral switching through the breaker is not required.
Yes. The EPX-XT2S-TM0503 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT2 mounting arrangement, electrical connections, enclosure compatibility and circuit protection settings should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, adjustable thermal-magnetic protection and dependable short-circuit interruption capability for modern low-voltage power systems.