1SDX254936R1 ABB EPX-XT2S-TM0403 40A 3P 50kA MCCB – TMA

ABB EPX-XT2S-TM0403 is a 40 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity at 415 V AC and an adjustable TMA thermal-magnetic trip unit, providing adjustable thermal overload and magnetic short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254936R1Alt SKU: EPX-XT2S-TM0403MPN: 1SDX254936R1
Price
List Price £451.41 ex VAT
Your Price (ex VAT)
£451.41
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £451.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£451.41

Why Choose the ABB EPX-XT2S-TM0403 40A 3-Pole 50kA MCCB?

The ABB EPX-XT2S-TM0403 is a high-performance 40 A three-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity at 415 V AC and an adjustable TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and incorporates ABB's established SACE Tmax XT2S circuit breaker technology.

Engineered for electrical installations requiring dependable circuit protection and substantial fault-current interruption capability, the EPX-XT2S-TM0403 combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. Its thermal-magnetic protection system operates without a separate electronic trip-unit power supply, providing a practical and robust solution for three-phase distribution circuits where straightforward operation, reliable protection and flexible settings are important.

With a 40 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-TM0403 is particularly suitable for three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX254936R1, this MCCB offers a versatile circuit protection solution for demanding low-voltage installations.

Key Advantages

  • 40 A rated current provides dependable overcurrent protection for appropriately rated three-phase electrical circuits.
  • Three-pole (3P) configuration enables simultaneous switching and protection of three phase conductors.
  • 50 kA short-circuit breaking capacity supports installations with relatively high prospective fault currents.
  • TMA thermal-magnetic trip unit combines adjustable overload and short-circuit protection in one device.
  • Adjustable thermal overload protection allows the protection threshold to be matched to conductor ratings and circuit requirements.
  • Adjustable magnetic short-circuit protection supports appropriate configuration of fault-current tripping thresholds.
  • Thermal overload setting range of 28–40 A provides flexibility for appropriately designed circuits.
  • Magnetic protection setting range of 200–400 A enables short-circuit protection adjustment.
  • Thermal-magnetic operating principle does not require a separate electronic trip-unit power supply.
  • ABB SACE Tmax XT2S construction combines compact dimensions with robust switching performance.
  • S breaking-capacity classification offers a higher short-circuit interruption rating than the corresponding XT2N 36 kA variant.
  • Compact three-pole design supports efficient use of space within distribution assemblies.
  • Manual toggle-operated mechanism provides straightforward switching and resetting.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for new installations, electrical distribution upgrades and compatible ABB MCCB replacement applications.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT2S moulded case circuit breaker platform.
  • 40 A rated current.
  • Three-pole (3P) configuration.
  • 50 kA short-circuit breaking capacity at 415 V AC.
  • TMA adjustable thermal-magnetic protection release.
  • Adjustable thermal overload protection: 0.7–1.0 × In.
  • Thermal overload adjustment range: 28–40 A.
  • Adjustable magnetic short-circuit protection: 5–10 × In.
  • Magnetic short-circuit adjustment range: 200–400 A.
  • Inverse-time thermal protection characteristic for sustained overload conditions.
  • Rapid magnetic tripping when the selected short-circuit threshold is reached.
  • Thermal-magnetic operating technology without an electronic trip-unit supply requirement.
  • XT2S 160 A frame family with a 40 A protective current rating.
  • Three-pole construction for appropriately designed three-phase electrical circuits.
  • Fixed-mounted MCCB platform for compatible electrical distribution assemblies.
  • Front-terminal connection arrangement on the corresponding XT2S TMA breaker.
  • 690 V AC rated operational voltage for the corresponding XT2S circuit breaker platform.
  • 1,000 V rated insulation voltage and 8 kV rated impulse withstand voltage.
  • Manual toggle operation for switching and resetting the breaker.
  • Mechanical trip indication through the circuit breaker operating mechanism.
  • Designed in accordance with IEC/EN 60947-2.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • ABB manufacturer order code: 1SDX254936R1.

Reliable 40A Thermal-Magnetic Circuit Protection with 50kA Breaking Capacity

The ABB EPX-XT2S-TM0403 combines the mechanical switching and short-circuit interruption capabilities of the ABB SACE Tmax XT2S platform with an adjustable TMA thermal-magnetic protection release. This combination provides protection against sustained overloads and high-current short circuits, helping protect electrical conductors, connected equipment and distribution infrastructure against abnormal current conditions.

The thermal overload protection function responds to excessive current flowing for a sustained period. Thermal protection uses an inverse-time operating characteristic, meaning that higher overload currents generally produce faster tripping. For the 40 A TMA configuration, the thermal protection threshold can be adjusted between 28 A and 40 A, corresponding to 0.7–1.0 times the rated current. This allows the overload protection setting to be selected according to the circuit's conductor ratings, expected load and installation requirements.

The magnetic short-circuit protection function provides rapid tripping when the current reaches the selected magnetic operating threshold. For the 40 A TMA release, the magnetic protection threshold can be adjusted between 200 A and 400 A, corresponding to 5–10 times the rated current. This provides flexibility when configuring the circuit breaker for the expected fault-current conditions and the protection requirements of connected electrical equipment.

The TMA thermal-magnetic trip unit offers a straightforward alternative to electronic protection releases. It uses thermal and magnetic operating principles rather than electronic sensing and processing. Unlike electronic trip units with configurable time-delay functions, TMA protection provides a conventional thermal overload response and magnetic short-circuit response. The available settings must be selected according to ABB's published trip curves and the electrical installation's design requirements.

A major advantage of the XT2S breaking-capacity classification is its specified 50 kA short-circuit breaking capacity at 415 V AC. This provides greater fault-interruption capability than the corresponding XT2N 36 kA variant at the same reference voltage. Higher breaking capacity can be particularly valuable where the circuit is located closer to the electrical supply or where the installation has a relatively high prospective short-circuit current.

The ABB SACE Tmax XT2S platform is rated for operation at voltages up to 690 V AC, although the available short-circuit breaking capacity decreases at higher operating voltages. For the corresponding XT2S TMA configuration, the breaking capacity is 50 kA at 415 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. The correct rating must always be selected according to the actual installation voltage and calculated prospective fault current.

The three-pole construction enables coordinated switching and protection of the three phase conductors in an appropriately designed three-phase electrical system. Because the EPX-XT2S-TM0403 is a three-pole device, it does not include a fourth switched neutral pole. Where neutral switching is required, an appropriately specified four-pole circuit breaker should be considered.

The ABB SACE Tmax XT2 160 A frame platform provides a robust mechanical foundation for the 40 A TMA protection configuration. Although the XT2 frame family supports ratings up to 160 A, the EPX-XT2S-TM0403 is specifically a 40 A rated protective device. The frame rating must not be confused with the rated current of the installed trip unit or the permissible current of the protected circuit.

As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0403 is intended for integration into compatible electrical distribution assemblies. Correct selection of mounting accessories, cable terminations, enclosure arrangements and protective settings is essential. The standard TMA release provides overload and short-circuit protection rather than residual-current or earth-leakage protection, so any required additional protective functions must be specified separately.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 40 A thermal-magnetic protection.
  • Distribution circuits with prospective fault currents requiring a 50 kA rated MCCB.
  • Commercial building electrical sub-distribution boards.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Building services and mechanical plant distribution circuits.
  • Electrical installations requiring adjustable thermal overload protection.
  • Three-phase equipment supply circuits where the load characteristics are compatible with the trip unit.
  • Electrical refurbishment and distribution board upgrades involving compatible ABB MCCBs.
  • Professional electrical installations requiring compact, high-breaking-capacity circuit protection.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT2 / Protecta Power
ABB order code 1SDX254936R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 40 A
Number of poles 3
Pole configuration 3P
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Breaking capacity classification S
Trip unit type TMA adjustable thermal-magnetic
Protection technology Thermal-magnetic overcurrent release
Overload protection Adjustable thermal
Short-circuit protection Adjustable magnetic
Thermal protection adjustment 0.7–1.0 × In
Thermal overload setting range 28–40 A
Magnetic protection adjustment 5–10 × In
Magnetic short-circuit setting range 200–400 A
Thermal protection characteristic Inverse-time
Magnetic protection characteristic Rapid tripping at the selected short-circuit threshold
Trip-unit power supply No separate electronic trip-unit supply required
Frame family XT2S
XT2 frame rating 160 A
Rated protective current 40 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate breaking capacity at 380–440 V AC 50 kA
Rated ultimate breaking capacity at 500 V AC 36 kA
Rated ultimate breaking capacity at 525 V AC 25 kA
Rated ultimate breaking capacity at 690 V AC 12 kA
Mounting configuration Fixed-mounted MCCB platform
Terminal configuration Front terminals
Operating mechanism Manual toggle-operated circuit breaker
Switching arrangement Three-pole simultaneous operation
Applicable circuit breaker standard IEC/EN 60947-2
Application Low-voltage electrical distribution
Installation type Compatible electrical distribution board / switchgear assembly
Typical electrical system Three-phase AC distribution

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0403 used for?

The ABB EPX-XT2S-TM0403 is a 40 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an adjustable TMA thermal-magnetic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT2S-TM0403?

The EPX-XT2S-TM0403 has a 40 A rated current. Its adjustable thermal protection can be configured below the rated current to suit appropriately designed electrical circuits.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT2S-TM0403 has a specified 50 kA short-circuit breaking capacity at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the circuit breaker.

What does TMA mean on an ABB MCCB?

TMA identifies an adjustable thermal-magnetic trip unit. It combines adjustable thermal protection against sustained overloads with adjustable magnetic protection against short-circuit currents.

What is the thermal overload adjustment range?

The 40 A TMA release provides a thermal overload adjustment range of 28–40 A, corresponding to 0.7–1.0 times the rated current. The appropriate setting must be selected according to the conductor ratings, expected load and electrical installation requirements.

What is the magnetic short-circuit adjustment range?

The magnetic protection threshold can be adjusted between 200 A and 400 A, corresponding to 5–10 times the 40 A rated current. The setting should be selected according to the installation's fault-current conditions and protection coordination requirements.

What is the difference between XT2S and XT2N MCCBs?

The XT2S and XT2N are ABB SACE Tmax XT2 breaking-capacity variants. For the corresponding Protecta Power configurations, the XT2S is specified with a 50 kA breaking capacity at 415 V AC, compared with 36 kA for the XT2N. The correct selection depends on the installation voltage and prospective short-circuit current.

Is the ABB EPX-XT2S-TM0403 suitable for three-phase distribution systems?

Yes. The three-pole (3P) configuration is designed for appropriately rated three-phase electrical distribution circuits requiring coordinated switching and protection of the three phase conductors. Where neutral switching is required, a suitable four-pole circuit breaker should be considered.

Does the ABB EPX-XT2S-TM0403 provide earth-leakage protection?

The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.

What is the ABB order code for the EPX-XT2S-TM0403?

The ABB manufacturer order code is 1SDX254936R1. The corresponding product reference is EPX-XT2S-TM0403, identifying the 40 A, three-pole, 50 kA adjustable thermal-magnetic MCCB within the ABB Protecta Power Devices range.

Trusted ABB Thermal-Magnetic Circuit Protection for Professional Installations

ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with reliable thermal-magnetic protection. The EPX-XT2S-TM0403 delivers dependable 40 A three-pole circuit protection, a 50 kA short-circuit breaking capacity and adjustable TMA overload and short-circuit protection for appropriately specified commercial and industrial low-voltage electrical distribution systems.