ABB EPX-XT2S-TM0403 is a 40 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity at 415 V AC and an adjustable TMA thermal-magnetic trip unit, providing adjustable thermal overload and magnetic short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£451.41
The ABB EPX-XT2S-TM0403 is a high-performance 40 A three-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity at 415 V AC and an adjustable TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and incorporates ABB's established SACE Tmax XT2S circuit breaker technology.
Engineered for electrical installations requiring dependable circuit protection and substantial fault-current interruption capability, the EPX-XT2S-TM0403 combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. Its thermal-magnetic protection system operates without a separate electronic trip-unit power supply, providing a practical and robust solution for three-phase distribution circuits where straightforward operation, reliable protection and flexible settings are important.
With a 40 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-TM0403 is particularly suitable for three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX254936R1, this MCCB offers a versatile circuit protection solution for demanding low-voltage installations.
The ABB EPX-XT2S-TM0403 combines the mechanical switching and short-circuit interruption capabilities of the ABB SACE Tmax XT2S platform with an adjustable TMA thermal-magnetic protection release. This combination provides protection against sustained overloads and high-current short circuits, helping protect electrical conductors, connected equipment and distribution infrastructure against abnormal current conditions.
The thermal overload protection function responds to excessive current flowing for a sustained period. Thermal protection uses an inverse-time operating characteristic, meaning that higher overload currents generally produce faster tripping. For the 40 A TMA configuration, the thermal protection threshold can be adjusted between 28 A and 40 A, corresponding to 0.7–1.0 times the rated current. This allows the overload protection setting to be selected according to the circuit's conductor ratings, expected load and installation requirements.
The magnetic short-circuit protection function provides rapid tripping when the current reaches the selected magnetic operating threshold. For the 40 A TMA release, the magnetic protection threshold can be adjusted between 200 A and 400 A, corresponding to 5–10 times the rated current. This provides flexibility when configuring the circuit breaker for the expected fault-current conditions and the protection requirements of connected electrical equipment.
The TMA thermal-magnetic trip unit offers a straightforward alternative to electronic protection releases. It uses thermal and magnetic operating principles rather than electronic sensing and processing. Unlike electronic trip units with configurable time-delay functions, TMA protection provides a conventional thermal overload response and magnetic short-circuit response. The available settings must be selected according to ABB's published trip curves and the electrical installation's design requirements.
A major advantage of the XT2S breaking-capacity classification is its specified 50 kA short-circuit breaking capacity at 415 V AC. This provides greater fault-interruption capability than the corresponding XT2N 36 kA variant at the same reference voltage. Higher breaking capacity can be particularly valuable where the circuit is located closer to the electrical supply or where the installation has a relatively high prospective short-circuit current.
The ABB SACE Tmax XT2S platform is rated for operation at voltages up to 690 V AC, although the available short-circuit breaking capacity decreases at higher operating voltages. For the corresponding XT2S TMA configuration, the breaking capacity is 50 kA at 415 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC and 12 kA at 690 V AC. The correct rating must always be selected according to the actual installation voltage and calculated prospective fault current.
The three-pole construction enables coordinated switching and protection of the three phase conductors in an appropriately designed three-phase electrical system. Because the EPX-XT2S-TM0403 is a three-pole device, it does not include a fourth switched neutral pole. Where neutral switching is required, an appropriately specified four-pole circuit breaker should be considered.
The ABB SACE Tmax XT2 160 A frame platform provides a robust mechanical foundation for the 40 A TMA protection configuration. Although the XT2 frame family supports ratings up to 160 A, the EPX-XT2S-TM0403 is specifically a 40 A rated protective device. The frame rating must not be confused with the rated current of the installed trip unit or the permissible current of the protected circuit.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0403 is intended for integration into compatible electrical distribution assemblies. Correct selection of mounting accessories, cable terminations, enclosure arrangements and protective settings is essential. The standard TMA release provides overload and short-circuit protection rather than residual-current or earth-leakage protection, so any required additional protective functions must be specified separately.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT2 / Protecta Power |
| ABB order code | 1SDX254936R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 40 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Rated ultimate short-circuit breaking capacity (Icu) | 50 kA at 415 V AC |
| Breaking capacity classification | S |
| Trip unit type | TMA adjustable thermal-magnetic |
| Protection technology | Thermal-magnetic overcurrent release |
| Overload protection | Adjustable thermal |
| Short-circuit protection | Adjustable magnetic |
| Thermal protection adjustment | 0.7–1.0 × In |
| Thermal overload setting range | 28–40 A |
| Magnetic protection adjustment | 5–10 × In |
| Magnetic short-circuit setting range | 200–400 A |
| Thermal protection characteristic | Inverse-time |
| Magnetic protection characteristic | Rapid tripping at the selected short-circuit threshold |
| Trip-unit power supply | No separate electronic trip-unit supply required |
| Frame family | XT2S |
| XT2 frame rating | 160 A |
| Rated protective current | 40 A |
| Rated operational voltage | Up to 690 V AC |
| Rated insulation voltage (Ui) | 1,000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated ultimate breaking capacity at 380–440 V AC | 50 kA |
| Rated ultimate breaking capacity at 500 V AC | 36 kA |
| Rated ultimate breaking capacity at 525 V AC | 25 kA |
| Rated ultimate breaking capacity at 690 V AC | 12 kA |
| Mounting configuration | Fixed-mounted MCCB platform |
| Terminal configuration | Front terminals |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Switching arrangement | Three-pole simultaneous operation |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Application | Low-voltage electrical distribution |
| Installation type | Compatible electrical distribution board / switchgear assembly |
| Typical electrical system | Three-phase AC distribution |
The ABB EPX-XT2S-TM0403 is a 40 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an adjustable TMA thermal-magnetic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-TM0403 has a 40 A rated current. Its adjustable thermal protection can be configured below the rated current to suit appropriately designed electrical circuits.
The ABB EPX-XT2S-TM0403 has a specified 50 kA short-circuit breaking capacity at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the circuit breaker.
TMA identifies an adjustable thermal-magnetic trip unit. It combines adjustable thermal protection against sustained overloads with adjustable magnetic protection against short-circuit currents.
The 40 A TMA release provides a thermal overload adjustment range of 28–40 A, corresponding to 0.7–1.0 times the rated current. The appropriate setting must be selected according to the conductor ratings, expected load and electrical installation requirements.
The magnetic protection threshold can be adjusted between 200 A and 400 A, corresponding to 5–10 times the 40 A rated current. The setting should be selected according to the installation's fault-current conditions and protection coordination requirements.
The XT2S and XT2N are ABB SACE Tmax XT2 breaking-capacity variants. For the corresponding Protecta Power configurations, the XT2S is specified with a 50 kA breaking capacity at 415 V AC, compared with 36 kA for the XT2N. The correct selection depends on the installation voltage and prospective short-circuit current.
Yes. The three-pole (3P) configuration is designed for appropriately rated three-phase electrical distribution circuits requiring coordinated switching and protection of the three phase conductors. Where neutral switching is required, a suitable four-pole circuit breaker should be considered.
The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.
The ABB manufacturer order code is 1SDX254936R1. The corresponding product reference is EPX-XT2S-TM0403, identifying the 40 A, three-pole, 50 kA adjustable thermal-magnetic MCCB within the ABB Protecta Power Devices range.
ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with reliable thermal-magnetic protection. The EPX-XT2S-TM0403 delivers dependable 40 A three-pole circuit protection, a 50 kA short-circuit breaking capacity and adjustable TMA overload and short-circuit protection for appropriately specified commercial and industrial low-voltage electrical distribution systems.