ABB EPX-XT2S-TM0323 is a 32 A three-pole moulded case circuit breaker with 50 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, providing thermal overload and magnetic short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£451.41
The ABB EPX-XT2S-TM0323 is a high-performance 32 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 50 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on ABB's established SACE Tmax XT2S circuit breaker platform.
Designed for electrical installations requiring dependable circuit protection and substantial fault-current interruption capability, the EPX-XT2S-TM0323 combines thermal overload protection with magnetic short-circuit protection. Its thermal-magnetic protection technology operates without requiring an electronic trip-unit power supply, offering a practical solution for three-phase distribution circuits where straightforward operation and reliable fault protection are essential.
With a 32 A rated current, three-pole configuration and 50 kA breaking capacity, the ABB EPX-XT2S-TM0323 is suitable for appropriately designed three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX254934R1, this MCCB offers a robust circuit protection solution for demanding low-voltage installations.
The ABB EPX-XT2S-TM0323 combines the mechanical switching and short-circuit interruption capabilities of the ABB SACE Tmax XT2S platform with a TMA thermal-magnetic protection release. This combination provides protection against two important electrical fault conditions: sustained overloads and high-current short circuits. By interrupting the circuit when the applicable trip conditions are reached, the MCCB helps protect electrical conductors, connected equipment and distribution infrastructure.
The thermal overload protection function responds to excessive current flowing for a sustained period. Thermal protection uses a time-dependent operating characteristic, meaning that higher overload currents generally produce faster tripping. This helps protect cables and electrical equipment against overheating while allowing the protective response to accommodate appropriate operating conditions within the circuit's design limits.
The magnetic short-circuit protection function provides rapid tripping when the current reaches the applicable magnetic operating threshold. This is particularly important during short-circuit faults, where current can rise significantly above normal operating levels. The magnetic release helps disconnect the affected circuit quickly, reducing the duration of fault-current exposure.
The TMA thermal-magnetic trip unit offers a straightforward alternative to electronic protection releases. It uses thermal and magnetic operating principles rather than electronic sensing and processing. Where a particular adjustment range is required, the available thermal and magnetic settings for the exact 32 A configuration should be confirmed against ABB's technical documentation before commissioning.
A major advantage of the XT2S breaking-capacity classification is its specified 50 kA short-circuit breaking capacity. This provides greater fault-interruption capability than the corresponding XT2N 36 kA variant at the relevant reference conditions. Higher breaking capacity can be particularly valuable where the circuit is located closer to the electrical supply or where the installation has a relatively high prospective short-circuit current.
The three-pole construction enables coordinated switching and protection of the three phase conductors in an appropriately designed three-phase electrical system. Because the EPX-XT2S-TM0323 is a three-pole device, it does not include a fourth switched neutral pole. Where neutral switching is required, an appropriately specified four-pole circuit breaker should be considered.
The ABB SACE Tmax XT2 frame platform supports circuit breakers with ratings up to 160 A, but the EPX-XT2S-TM0323 is specifically a 32 A rated protective device. The frame family's maximum current rating must not be confused with the rated current of the installed protection release. Conductor sizing and protective device selection must be based on the actual circuit breaker rating and applicable installation requirements.
As part of the ABB Protecta Power Devices range, the EPX-XT2S-TM0323 is intended for integration into compatible electrical distribution assemblies. Correct selection of mounting accessories, cable terminations and enclosure arrangements is essential. The specified 50 kA breaking capacity must also be checked against the installation's operating voltage and prospective fault current before the MCCB is selected.
The standard TMA release provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where additional earth-leakage protection is required, an appropriate residual-current protective device or compatible solution must be specified separately.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT2 / Protecta Power |
| ABB order code | 1SDX254934R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 32 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Short-circuit breaking capacity | 50 kA |
| Breaking capacity classification | S |
| Trip unit type | TMA thermal-magnetic |
| Protection technology | Thermal-magnetic overcurrent release |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Thermal protection characteristic | Inverse-time |
| Magnetic protection characteristic | Rapid tripping at the applicable fault-current threshold |
| Trip-unit power supply | No separate electronic trip-unit supply required |
| Frame family | XT2S |
| XT2 frame family maximum current rating | 160 A |
| Rated protective current | 32 A |
| Rated operational voltage | Subject to the applicable XT2S configuration and manufacturer's ratings |
| Short-circuit rating reference | Verify the 50 kA rating at the installation's operating voltage |
| Mounting configuration | Fixed-mounted MCCB platform |
| Terminal configuration | Front terminals on the corresponding XT2S configuration |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Switching arrangement | Three-pole simultaneous operation |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Application | Low-voltage electrical distribution |
| Installation type | Compatible electrical distribution board / switchgear assembly |
| Typical electrical system | Three-phase AC distribution |
The ABB EPX-XT2S-TM0323 is a 32 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses a TMA thermal-magnetic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2S-TM0323 has a 32 A rated current. It is intended for appropriately designed electrical circuits where the conductor ratings, expected load and protection characteristics are compatible with the circuit breaker.
The ABB EPX-XT2S-TM0323 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the circuit breaker.
TMA identifies a thermal-magnetic trip unit. It combines thermal protection against sustained overloads with magnetic protection against short-circuit currents. The available adjustment settings depend on the exact trip-unit configuration.
Thermal protection responds to overload conditions using a time-dependent characteristic, helping protect conductors against overheating. Magnetic protection responds rapidly when a sufficiently high short-circuit current is detected. Both functions work together to provide overcurrent protection.
The XT2S and XT2N are ABB SACE Tmax XT2 breaking-capacity variants. For the corresponding Protecta Power configurations, the XT2S is specified with a 50 kA breaking capacity, compared with 36 kA for the XT2N. The correct selection depends on the installation voltage and prospective short-circuit current.
TMA thermal-magnetic releases may provide adjustable protection settings depending on the exact device configuration. The available thermal and magnetic adjustment ranges for the 32 A EPX-XT2S-TM0323 should be confirmed against the applicable ABB technical documentation before installation or commissioning.
Yes. The three-pole (3P) configuration is designed for appropriately rated three-phase electrical distribution circuits requiring coordinated switching and protection of the three phase conductors. Where neutral switching is required, a suitable four-pole circuit breaker should be considered.
The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.
The ABB manufacturer order code is 1SDX254934R1. The corresponding product reference is EPX-XT2S-TM0323, identifying the 32 A, three-pole, 50 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.
ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with reliable thermal-magnetic protection. The EPX-XT2S-TM0323 delivers dependable 32 A three-pole circuit protection, a 50 kA short-circuit breaking capacity and practical TMA overload and short-circuit protection for appropriately specified commercial and industrial low-voltage electrical distribution systems.