1SDX254933R1 ABB EPX-XT2S-TM0253 25A 3P 50kA MCCB TMA Thermal-Magnetic

1SDX254933R1 ABB EPX-XT2S-TM0253 25A 3P 50kA MCCB TMA Thermal-Magnetic

ABB EPX-XT2S-TM0253 is a 25 A three-pole SACE Tmax XT2S160 moulded case circuit breaker with 50 kA breaking capacity and TMA thermal-magnetic overload and short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254933R1Alt SKU: EPX-XT2S-TM0253MPN: 1SDX254933R1
Price
List Price £451.41 ex VAT
Your Price (ex VAT)
£451.41
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £451.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£451.41

Why Choose the ABB EPX-XT2S-TM0253 Protecta Power Circuit Breaker?

The ABB EPX-XT2S-TM0253 is a 25 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection for commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker is based on the ABB SACE Tmax XT2S160 platform and features a TMA thermal-magnetic trip unit, combining established protection technology with a compact circuit breaker design.

Featuring a 50 kA short-circuit breaking capacity, the EPX-XT2S-TM0253 provides enhanced fault-interruption capability for electrical installations where higher prospective short-circuit currents must be accommodated. Its thermal-magnetic protection combines thermal overload protection with magnetic short-circuit protection, helping safeguard electrical cables, distribution equipment and connected loads against potentially damaging electrical faults.

With a 25 A rated current, three-pole configuration and compact XT2 frame construction, this MCCB is particularly suitable for three-phase outgoing circuits requiring dependable protection. Its robust ABB design, straightforward operating mechanism and compatibility with appropriately configured ABB Protecta Power distribution boards make it a practical choice for electrical contractors, panel builders and maintenance engineers.

Key Advantages

  • 25 A rated current provides protection for appropriately designed low-voltage electrical distribution circuits.
  • Three-pole (3P) configuration enables coordinated switching and protection of three phase conductors.
  • 50 kA short-circuit breaking capacity offers enhanced fault-interruption capability for demanding electrical installations.
  • TMA thermal-magnetic trip unit combines thermal overload and magnetic short-circuit protection.
  • Thermal overload protection responds to sustained excessive current, helping prevent overheating of electrical conductors.
  • Magnetic short-circuit protection provides rapid tripping when significant fault currents occur.
  • Adjustable thermal-magnetic protection supports appropriate selection of protective characteristics within the trip unit's available settings.
  • ABB SACE Tmax XT2S160 platform combines compact construction with established circuit protection technology.
  • 100 mm nominal installation width for the Protecta Power three-pole XT2 arrangement.
  • Self-contained protection mechanism operates without a separate electronic trip-unit power supply.
  • Suitable for commercial and industrial three-phase electrical distribution circuits.
  • Designed for integration into compatible ABB Protecta Power electrical distribution assemblies.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT2S-TM0253 model designation.
  • ABB SACE Tmax XT2S moulded case circuit breaker platform.
  • 25 A rated current.
  • XT2S160 frame with a maximum frame rating of 160 A.
  • Three-pole (3P) circuit breaker construction.
  • 50 kA short-circuit breaking capacity.
  • TMA thermal-magnetic trip unit.
  • Thermal protection: Overload protection using a temperature-responsive tripping mechanism.
  • Magnetic protection: Short-circuit protection using an electromagnetic tripping mechanism.
  • Adjustable protection characteristics within the TMA trip unit's specified operating range.
  • Three-pole switching capability for compatible three-phase electrical distribution circuits.
  • Manual operating mechanism for circuit switching and resetting.
  • Compact moulded case construction for integration into compatible electrical assemblies.
  • Suitable for low-voltage AC electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.
  • Suitable for use with correctly specified terminal covers and protective connection arrangements.
  • Designed for outgoing feeder protection in commercial and industrial switchboards.
  • Thermal-magnetic protection provides an alternative to electronic-trip MCCBs where the installation requirements permit.
  • Suitable for installations requiring a higher breaking capacity than comparable 36 kA XT2N configurations.

Reliable TMA Thermal-Magnetic Protection for Three-Phase Distribution

The ABB EPX-XT2S-TM0253 incorporates a TMA thermal-magnetic trip unit designed to protect electrical installations against sustained overloads and short-circuit faults. Thermal-magnetic protection uses established electromechanical operating principles, providing dependable circuit protection without requiring a separate electronic trip-unit power supply.

The thermal protection element responds to excessive current sustained over time. When current exceeds the permitted operating conditions, the thermal mechanism develops the response required to trip the circuit breaker. This inverse-time behaviour helps protect cables and connected electrical equipment against overheating caused by prolonged overloads.

The magnetic protection element responds to high fault currents associated with short circuits. When the magnetic operating threshold is reached, the circuit breaker trips rapidly to interrupt the fault. The TMA arrangement provides adjustable protection characteristics within the specified trip unit range, allowing settings to be selected to suit the installation.

The 50 kA short-circuit breaking capacity makes the XT2S performance level particularly relevant where a higher fault-interruption rating is required. Electrical designers must confirm the applicable breaking capacity at the system operating voltage and verify that the selected device is suitable for the prospective short-circuit current at its installation point.

The three-pole configuration allows coordinated switching and protection of the three phase conductors in a three-phase circuit. Unlike a four-pole MCCB, this arrangement does not provide a fourth switched pole for the neutral conductor. Device selection must therefore take account of the installation's neutral arrangements, earthing system and applicable electrical standards.

When installing the EPX-XT2S-TM0253 within an ABB Protecta Power distribution board, appropriate mounting components, terminal connections and protective covers must be selected. Electrical designers should verify conductor ratings, prospective fault current, thermal-magnetic trip settings and protective device coordination before commissioning.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical switchboards and distribution panels.
  • 25 A three-pole outgoing feeder protection.
  • Three-phase electrical distribution circuits.
  • Building services and mechanical plant distribution.
  • Commercial premises and office building electrical infrastructure.
  • Manufacturing and industrial facility electrical installations.
  • Commercial switchboards and sub-distribution assemblies.
  • Electrical panel building and switchboard manufacturing.
  • Distribution circuits requiring thermal-magnetic overload and short-circuit protection.
  • Electrical installations requiring a suitable 50 kA breaking capacity at the applicable operating voltage.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series SACE Tmax XT
Circuit breaker frame XT2
Performance level XT2S
Frame configuration XT2S160
ABB order code 1SDX254933R1
Product type Moulded case circuit breaker (MCCB)
Rated current 25 A
Maximum frame rating 160 A
Number of poles 3P (three pole)
Short-circuit breaking capacity 50 kA
Trip unit TMA
Trip technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Protection adjustment According to the TMA trip unit's specified settings
Rated frequency 50/60 Hz
Nominal Protecta Power installation width 100 mm
Applicable standard IEC 60947-2
Installation type Electrical distribution board / switchboard mounting
Compatible system ABB Protecta Power
Product category Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT2S-TM0253 used for?

The ABB EPX-XT2S-TM0253 is a 25 A three-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using a TMA thermal-magnetic trip unit.

What is the rated current of the EPX-XT2S-TM0253?

The EPX-XT2S-TM0253 has a 25 A rated current and uses the ABB SACE Tmax XT2S160 platform, which has a maximum frame rating of 160 A. The frame rating does not change the specified 25 A rating of this device.

What is the breaking capacity of this circuit breaker?

The EPX-XT2S-TM0253 is specified with a 50 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.

What does TMA mean on the ABB EPX-XT2S-TM0253?

TMA identifies an adjustable thermal-magnetic trip unit. It combines a thermal element for overload protection with a magnetic element for short-circuit protection, allowing protection characteristics to be selected within the available adjustment range.

What is the difference between TMA thermal-magnetic and Ekip electronic protection?

TMA thermal-magnetic protection uses thermal and electromagnetic mechanisms to detect overloads and short circuits. Ekip electronic protection uses current sensing and electronic processing to provide configurable protective characteristics. The appropriate technology depends on the circuit design, protection coordination requirements and available device settings.

What is the difference between the EPX-XT2N-TM0253 and EPX-XT2S-TM0253?

Both circuit breakers are 25 A three-pole thermal-magnetic MCCBs based on the ABB SACE Tmax XT2 platform. The EPX-XT2N-TM0253 is specified with a 36 kA breaking capacity, while the EPX-XT2S-TM0253 has a higher specified breaking capacity of 50 kA.

What is the difference between the EPX-XT2S-TM0203 and EPX-XT2S-TM0253?

Both models are three-pole ABB XT2S thermal-magnetic MCCBs with a specified breaking capacity of 50 kA. The EPX-XT2S-TM0203 is rated at 20 A, while the EPX-XT2S-TM0253 is rated at 25 A. The correct device should be selected according to conductor capacity, load characteristics and protection requirements.

Can the EPX-XT2S-TM0253 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2S-TM0253 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT2 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.

Trusted ABB Thermal-Magnetic Circuit Protection for Electrical Distribution

ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT2S-TM0253 combines a 25 A three-pole XT2S160 circuit breaker with 50 kA breaking capacity and TMA thermal-magnetic protection, delivering a compact and practical solution for compatible ABB Protecta Power distribution assemblies.