ABB EPX-XT2S-TM0203 is a 20 A three-pole SACE Tmax XT2S160 moulded case circuit breaker with 50 kA breaking capacity and TMA thermal-magnetic overload and short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£451.41
The ABB EPX-XT2S-TM0203 is a reliable 20 A three-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the ABB SACE Tmax XT2S160 platform with a thermal-magnetic (TMA) trip unit, providing dependable circuit protection without requiring an electronic trip unit or auxiliary power supply for its protective operation.
Featuring a 50 kA short-circuit breaking capacity, the EPX-XT2S-TM0203 is designed for installations requiring a higher fault-interruption capability than standard 36 kA MCCB configurations. Its thermal-magnetic protection combines thermal overload protection with magnetic short-circuit protection, helping safeguard electrical conductors, distribution equipment and connected loads against potentially damaging fault conditions.
With a 20 A rated current, three-pole configuration and compact 100 mm nominal width, this MCCB is suitable for three-phase electrical circuits where all three phase conductors require coordinated switching and protection. Its established ABB Tmax XT2S construction makes it a practical choice for electrical contractors, panel builders and maintenance engineers working with ABB Protecta Power distribution boards and commercial switchboards.
The ABB EPX-XT2S-TM0203 incorporates a TMA thermal-magnetic trip unit designed to protect electrical installations against sustained overloads and short-circuit faults. Thermal-magnetic protection uses established electromechanical operating principles, providing dependable protective operation without the need for a separate electronic trip-unit power supply.
The thermal protection element responds to excessive current sustained over time. As current increases beyond the permitted operating conditions, the thermal mechanism develops the response required to trip the circuit breaker. This inverse-time behaviour helps protect cables and connected electrical equipment against overheating caused by prolonged overloads.
The magnetic protection element responds to high fault currents associated with short circuits. When the magnetic operating threshold is reached, the circuit breaker trips rapidly to interrupt the fault. The TMA arrangement provides adjustable protection characteristics, allowing settings to be selected within the available adjustment range for the installation.
The 50 kA short-circuit breaking capacity makes the XT2S performance level particularly relevant where a higher fault-interruption rating is required. Electrical designers must confirm the applicable breaking capacity at the system operating voltage and verify that the selected device is suitable for the prospective short-circuit current at its installation point.
The three-pole configuration allows coordinated switching and protection of the three phase conductors in a three-phase circuit. Unlike a four-pole MCCB, this configuration does not provide a fourth switched pole for the neutral conductor. Selection must therefore take account of the installation's neutral arrangements, earthing system and applicable electrical standards.
When installing the EPX-XT2S-TM0203 within an ABB Protecta Power distribution board, appropriate mounting components, terminal connections and protective covers must be selected. Electrical designers should verify conductor ratings, prospective fault current, thermal-magnetic trip settings and protective device coordination before commissioning.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | SACE Tmax XT |
| Circuit breaker frame | XT2 |
| Performance level | XT2S |
| Frame configuration | XT2S160 |
| ABB order code | 1SDX254931R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 20 A |
| Maximum frame rating | 160 A |
| Number of poles | 3P (three pole) |
| Short-circuit breaking capacity | 50 kA |
| Trip unit | TMA |
| Trip technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Protection adjustment | Thermal-magnetic settings subject to the trip unit's specified adjustment range |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated frequency | 50/60 Hz |
| Nominal width | 100 mm |
| Applicable standard | IEC 60947-2 |
| Installation type | Electrical distribution board / switchboard mounting |
| Compatible system | ABB Protecta Power |
| Product category | Protecta Power Devices |
The ABB EPX-XT2S-TM0203 is a 20 A three-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using a TMA thermal-magnetic trip unit.
The EPX-XT2S-TM0203 has a 20 A rated current and uses the ABB SACE Tmax XT2S160 platform, which has a maximum frame rating of 160 A. The frame rating does not change the specified 20 A rating of this device.
The EPX-XT2S-TM0203 is specified with a 50 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.
TMA identifies an adjustable thermal-magnetic trip unit. It combines a thermal element for overload protection with a magnetic element for short-circuit protection, allowing protection characteristics to be selected within the available adjustment range.
TMA thermal-magnetic protection uses thermal and electromagnetic mechanisms to detect overloads and short circuits. Ekip electronic protection uses current sensing and electronic processing to provide configurable protective characteristics. The appropriate technology depends on the circuit design, protection coordination requirements and available device settings.
Both circuit breakers are 20 A three-pole thermal-magnetic MCCBs based on the ABB SACE Tmax XT2 platform. The EPX-XT2N-TM0203 is specified with a 36 kA breaking capacity, while the EPX-XT2S-TM0203 has a higher specified breaking capacity of 50 kA.
The ABB EPX-XT2S-TM0203 uses the three-pole XT2 frame arrangement with a nominal width of 100 mm. Additional installation clearance may be required depending on the mounting arrangement, terminals and accessories.
Yes. The EPX-XT2S-TM0203 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT2 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.
ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT2S-TM0203 combines a 20 A three-pole XT2S160 circuit breaker with 50 kA breaking capacity and TMA thermal-magnetic protection, delivering a compact and practical solution for compatible ABB Protecta Power distribution assemblies.