Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT1S-TM0253 is a 25 A three-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 50 kA short-circuit breaking capacity and TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.
£394.63
The ABB EPX-XT1S-TM0253 is a compact, high-performance 25 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT1S160 platform, offering reliable protection for commercial buildings, industrial facilities and electrical infrastructure.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT1S-TM0253 combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid interruption of short-circuit faults. This combination helps safeguard distribution cables, switchgear and connected electrical equipment while providing a straightforward protection solution without the need for an electronic trip unit.
With a 25 A rated current, three-pole construction and 50 kA short-circuit breaking capacity, the EPX-XT1S-TM0253 is suitable for three-phase distribution circuits requiring a relatively low current rating and substantial fault-interruption capability. Its compact 80 mm three-pole frame width supports efficient installation in compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.
Moulded case circuit breakers such as the ABB EPX-XT1S-TM0253 protect electrical installations by automatically interrupting current during overload and short-circuit conditions. Its TMA thermal-magnetic trip unit incorporates a thermal element that responds to sustained overcurrent and a magnetic element that provides rapid interruption during short-circuit faults. These complementary protection functions help protect electrical cables, distribution equipment and connected circuits against potentially damaging electrical conditions.
The ABB SACE Tmax XT1 circuit breaker family is engineered for dependable protection in compact low-voltage electrical distribution assemblies. The EPX-XT1S-TM0253 is particularly suitable for installations requiring 25 A three-pole circuit protection and a 50 kA short-circuit breaking rating. Circuit breaker selection should account for the installation's operating voltage, prospective fault current, cable characteristics, load requirements and protective device coordination. For motor feeder applications, separate motor overload protection may be necessary depending on the circuit design.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT |
| Frame designation | XT1S160 |
| ABB order code | 1SDX254912R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 25 A |
| Number of poles | 3 |
| Short-circuit breaking capacity | 50 kA |
| Trip unit | TMA |
| Trip unit technology | Thermal-magnetic |
| Overload protection | Thermal trip element |
| Short-circuit protection | Magnetic trip element |
| Protection functions | Overload and short-circuit protection |
| Frame family | XT1S160 |
| Maximum frame rating | 160 A |
| Three-pole frame width | 80 mm |
| Number of protected phases | 3 |
| Operating mechanism | Manual operation |
| Application | Low-voltage three-phase electrical distribution |
| Installation | Compatible electrical distribution boards and switchgear assemblies |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
The ABB EPX-XT1S-TM0253 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial three-phase electrical installations.
The circuit breaker has a 25 A rated current and uses the ABB Tmax XT1S160 frame. Although the XT1S160 frame has a maximum rating of 160 A, this particular MCCB is specified for a rated current of 25 A.
The EPX-XT1S-TM0253 has a specified 50 kA short-circuit breaking capacity. The applicable breaking capacity at the installation's operating voltage must be verified against ABB technical documentation and the prospective fault current before selection.
The TMA thermal-magnetic trip unit combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid tripping during short-circuit faults, helping safeguard cables and connected electrical equipment.
This MCCB is typically installed in low-voltage electrical distribution boards, industrial control panels and compatible ABB Protecta Power assemblies. Its three-pole construction and compact 80 mm frame width make it suitable for space-conscious three-phase electrical distribution applications.
ABB SACE Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT1S-TM0253 combines a 25 A rating, three-pole construction, 50 kA breaking capacity and thermal-magnetic protection in a compact solution for commercial, industrial and building services electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.