1SDX254910R1 ABB EPX-XT1S-TM0163 16A 3-Pole 50kA TMA Thermal-Magnetic MCCB

1SDX254910R1 ABB EPX-XT1S-TM0163 16A 3-Pole 50kA TMA Thermal-Magnetic MCCB

ABB EPX-XT1S-TM0163 is a 16 A three-pole 50 kA moulded case circuit breaker from the Protecta Power Devices range, featuring TMA thermal-magnetic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX254910R1Alt SKU: EPX-XT1S-TM0163MPN: 1SDX254910R1
Price
List Price £394.63 ex VAT
Your Price (ex VAT)
£394.63
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £394.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£394.63

Why Choose the ABB EPX-XT1S-TM0163 16A 3-Pole 50kA MCCB?

The ABB EPX-XT1S-TM0163 is a compact, high-performance 16 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Manufactured by ABB and supplied under the Protecta Power Devices product group, this circuit breaker combines the established ABB SACE Tmax XT1S platform with thermal-magnetic protection technology for commercial, industrial and building services installations.

Featuring a thermal-magnetic TMA trip unit, the EPX-XT1S-TM0163 provides two essential protection functions: thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element enables rapid circuit interruption during short-circuit conditions. This combination provides dependable circuit protection without requiring an electronic trip unit or auxiliary control power supply.

With a rated current of 16 A, a three-pole configuration and a specified 50 kA short-circuit breaking capacity, this MCCB is particularly suitable for three-phase outgoing circuits requiring a relatively low current rating alongside substantial fault interruption capability. Its compact XT1 construction makes it a practical choice for compatible ABB Protecta Power distribution boards, electrical control panels and low-voltage switchgear assemblies.

Key Advantages

  • 16 A rated current: Suitable for protecting appropriately designed low-current electrical distribution circuits.
  • Three-pole configuration: Provides coordinated switching and protection of three phase conductors.
  • 50 kA breaking capacity: Offers substantial short-circuit interruption capability under the applicable rated conditions.
  • Thermal-magnetic protection: Combines overload and short-circuit protection within one compact MCCB.
  • TMA trip technology: Provides conventional thermal-magnetic protection characteristics without electronic monitoring equipment.
  • Thermal overload response: Helps protect cables and connected equipment against sustained excessive current.
  • Magnetic short-circuit response: Provides rapid interruption when fault current reaches the magnetic trip threshold.
  • ABB SACE Tmax XT1S platform: Uses established ABB circuit breaker technology for dependable electrical protection.
  • Compact construction: Helps conserve installation space in compatible electrical distribution assemblies.
  • Protecta Power compatibility: Designed for integration into appropriately configured ABB Protecta Power distribution systems.
  • Mechanical switching: Supports manual operation and circuit isolation in accordance with manufacturer requirements.
  • Versatile applications: Suitable for commercial distribution boards, industrial panels and building infrastructure.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Circuit breaker series: ABB SACE Tmax XT1.
  • Frame designation: XT1S.
  • Rated current: 16 A.
  • Number of poles: 3.
  • Specified short-circuit breaking capacity: 50 kA.
  • Trip unit type: TMA thermal-magnetic.
  • Thermal protection: Overload protection using a temperature-responsive trip mechanism.
  • Magnetic protection: Short-circuit protection using an electromagnetic trip mechanism.
  • Protection functions: Overload and short-circuit protection.
  • Frame family: ABB Tmax XT1, 160 A frame class.
  • Three-pole switching: Simultaneous operation of three phase conductors.
  • Manual operation: Front-operated circuit breaker switching mechanism.
  • Trip indication: Mechanical operating mechanism indicates the tripped condition.
  • Accessory compatibility: Supports appropriately selected ABB Tmax XT1 accessories and installation components.
  • Distribution board integration: Intended for compatible ABB Protecta Power assemblies.
  • Product family standard: IEC/EN 60947-2.

Reliable TMA Thermal-Magnetic Protection for Low-Voltage Circuits

The ABB EPX-XT1S-TM0163 protects electrical circuits using a combination of thermal and magnetic trip mechanisms. During sustained overload conditions, the thermal element responds to excessive current and initiates circuit interruption according to its time-current characteristics. This helps reduce the risk of overheating in conductors and connected equipment. During short-circuit conditions, the magnetic element responds rapidly when the fault current reaches the applicable trip threshold, allowing the breaker to interrupt the circuit before excessive fault energy can cause further damage.

The TMA thermal-magnetic protection system provides a practical alternative to electronic trip units for installations where conventional overload and short-circuit protection characteristics are appropriate. Its operation does not depend on electronic monitoring or an external auxiliary power supply. Protection settings and operating characteristics must nevertheless be selected in accordance with the connected load, conductor capacity and electrical installation design.

One of the principal benefits of the ABB SACE Tmax XT1S platform is its combination of compact construction and substantial short-circuit interruption capability. The EPX-XT1S-TM0163 provides a relatively low 16 A rated current together with a specified 50 kA breaking capacity, making it suitable for appropriately engineered circuits in distribution systems with significant prospective fault currents. Electrical designers should verify the applicable operating voltage, short-circuit ratings, cable protection requirements and coordination with upstream and downstream devices before installation.

Typical Applications

  • ABB Protecta Power distribution boards: Protection of compatible low-current outgoing circuits.
  • Commercial electrical installations: Three-phase circuit protection in offices, retail premises and commercial buildings.
  • Industrial electrical panels: Overload and short-circuit protection for appropriately rated circuits.
  • Sub-distribution boards: Protection of individual three-phase outgoing feeders.
  • Electrical control panels: Protection of control equipment supply circuits where a 16 A MCCB is appropriate.
  • Building services: Electrical protection for suitably rated mechanical and electrical equipment.
  • Industrial machinery supplies: Feeder protection where the selected thermal-magnetic characteristics are compatible with equipment requirements.
  • Commercial infrastructure: Distribution systems in warehouses, educational facilities and public buildings.
  • High-fault-level distribution networks: Circuits requiring a 50 kA short-circuit breaking capacity under the specified operating conditions.
  • Panel building projects: Electrical assemblies incorporating the ABB SACE Tmax XT1 circuit breaker platform.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT1
Product model EPX-XT1S-TM0163
ABB order code 1SDX254910R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT1S
Frame current class 160 A
Rated current (In) 16 A
Number of poles 3
Specified short-circuit breaking capacity 50 kA
Trip unit technology Thermal-magnetic
Trip unit designation TMA
Overload protection Thermal trip mechanism
Short-circuit protection Magnetic trip mechanism
Rated insulation voltage (Ui), XT1 series 800 V
Rated impulse withstand voltage (Uimp), XT1 series 8 kV
Electrical system Low-voltage AC distribution
Phase configuration Three-phase
Operating mechanism Manual toggle operation
Primary function Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT1S-TM0163 used for?

The ABB EPX-XT1S-TM0163 is a 16 A three-pole thermal-magnetic moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial electrical panels.

What is the rated current of the EPX-XT1S-TM0163?

The EPX-XT1S-TM0163 has a 16 A rated current. It belongs to the ABB SACE Tmax XT1 frame family, which includes higher-current circuit breakers, but the rated current of this particular device is 16 A.

What is the breaking capacity of this ABB MCCB?

The circuit breaker has a specified 50 kA short-circuit breaking capacity. The applicable rated operating voltage and manufacturer short-circuit rating conditions must be checked against the prospective fault current at the installation location.

What does TMA thermal-magnetic protection mean?

TMA identifies a thermal-magnetic trip unit combining thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid tripping during short-circuit conditions.

What is the difference between a TMA MCCB and an electronic MCCB?

A TMA MCCB uses thermal and magnetic trip mechanisms to provide overload and short-circuit protection. An electronic MCCB uses electronic current monitoring and may provide additional adjustable protection functions. The appropriate technology depends on circuit characteristics, protection coordination requirements and the electrical installation design.

Is the EPX-XT1S-TM0163 suitable for three-phase electrical systems?

Yes. The EPX-XT1S-TM0163 has a three-pole configuration for switching and protecting three phase conductors. It is suitable for appropriately designed three-phase low-voltage electrical distribution circuits where neutral switching through the breaker is not required.

What is the difference between ABB XT1N and XT1S circuit breakers?

XT1N and XT1S identify different short-circuit performance versions within the ABB SACE Tmax XT1 family. In the ABB Protecta Power range, the specified XT1N variants have a 36 kA breaking capacity, while the corresponding XT1S variants provide 50 kA. Selection should be based on the prospective fault current and applicable voltage rating.

Can the EPX-XT1S-TM0163 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT1S-TM0163 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The correct XT1 mounting arrangement, electrical connections, enclosure compatibility and circuit protection requirements should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining compact construction, dependable thermal-magnetic operation and robust short-circuit protection for modern low-voltage power systems.