Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT5N-E2-6304 is a 630 A four-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring an Ekip LSI trip unit with long-time, short-time and instantaneous protection for high-current low-voltage electrical distribution systems.
£3,240.00
The ABB EPX-XT5N-E2-6304 is a high-performance 630 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT5N 630 A platform, combining robust construction with advanced electronic protection technology for commercial buildings, industrial facilities and electrical distribution assemblies.
Equipped with an ABB Ekip LSI electronic trip unit, the EPX-XT5N-E2-6304 provides three essential protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These electronic protection characteristics enable electrical engineers to configure suitable trip settings, coordinate protective devices and support reliable operation within demanding low-voltage distribution networks.
With a rated current of 630 A, a four-pole configuration and a specified 36 kA short-circuit breaking capacity, this MCCB is suitable for protecting high-current three-phase distribution feeders incorporating a neutral conductor. Its 190 mm-wide XT5 frame supports integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, switchboard manufacturers and maintenance engineers requiring advanced electronic circuit protection.
The ABB EPX-XT5N-E2-6304 uses electronic current monitoring to protect electrical circuits against abnormal operating conditions. Its long-time (L) protection responds to sustained overloads that could otherwise cause excessive cable temperatures or damage connected equipment. The short-time (S) protection introduces a controlled delay for selected short-circuit conditions, supporting coordination with downstream protective devices. The instantaneous (I) protection provides rapid circuit interruption when high-current faults exceed the configured protection threshold.
A significant advantage of the ABB Ekip LSI trip unit is that all three protection characteristics are available within the same electronic protection system. Unlike LS/I configurations, where short-time and instantaneous protection are selected as alternatives, LSI protection incorporates both functions. This provides greater flexibility when configuring circuit protection and can help improve selectivity, minimise unnecessary upstream interruptions and support effective fault management in appropriately engineered electrical distribution networks.
The ABB SACE Tmax XT5N platform combines these electronic protection capabilities with robust moulded case construction suitable for higher-current electrical distribution. Its four-pole configuration supports coordinated switching of three phase conductors and a neutral conductor, while its 630 A rating makes it suitable for substantial distribution feeders. Correct selection of trip settings, cable ratings, neutral protection requirements, operating voltage, prospective short-circuit current and protective device coordination remains essential for safe and reliable operation.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT5 |
| Product model | EPX-XT5N-E2-6304 |
| ABB order code | 1SDX254857R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT5N 630 |
| Frame current class | 630 A |
| Rated current (In) | 630 A |
| Number of poles | 4 |
| Specified short-circuit breaking capacity | 36 kA |
| Trip unit technology | Electronic |
| Trip unit | ABB Ekip LSI |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Delayed short-circuit protection |
| Instantaneous protection (I) | Instantaneous short-circuit protection |
| Protection characteristics | LSI |
| Electrical system | Low-voltage AC distribution |
| Phase configuration | Three-phase with neutral |
| Nominal device width | 190 mm |
| Operating mechanism | Manual circuit breaker operation |
| Primary function | Overload and short-circuit protection |
| Additional function | Circuit switching and isolation in accordance with manufacturer installation requirements |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT5N-E2-6304 is a 630 A four-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards, commercial electrical systems and industrial switchgear assemblies.
The EPX-XT5N-E2-6304 has a 630 A rated current and uses the ABB SACE Tmax XT5N 630 A frame platform. It is intended for appropriately designed high-current electrical distribution circuits requiring electronic protection.
The circuit breaker has a specified 36 kA short-circuit breaking capacity. The applicable rated operating voltage, manufacturer short-circuit rating conditions and installation prospective fault current must be checked when selecting the device.
Ekip LSI is an electronic trip system incorporating long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide adjustable protection characteristics for low-voltage electrical distribution applications.
Ekip LSI incorporates long-time, short-time and instantaneous protection characteristics within the same electronic trip system. Ekip LS/I provides long-time protection together with a choice between short-time and instantaneous protection. LSI therefore offers additional flexibility when coordinating protective devices.
The four-pole (4P) configuration provides coordinated switching of three phase conductors and a neutral conductor. This makes the breaker suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. Neutral protection settings should be verified for the selected circuit breaker configuration.
The ABB Protecta Power XT5 four-pole circuit breaker format has a 190 mm nominal width. Installation space must also account for the correct mounting arrangement, cable terminations, electrical clearances and any required accessories. For XT5 outgoing devices, ABB recommends considering a side cableway extension box where additional space is needed for larger cables.
Yes. The EPX-XT5N-E2-6304 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The appropriate XT5 mounting arrangement, electrical connections, cable accommodation, enclosure compatibility and electronic protection settings should be verified before installation.
ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining adjustable electronic trip functionality, robust construction and dependable overload and short-circuit protection for modern high-current low-voltage power systems.