1SDX254857R1 ABB EPX-XT5N-E2-6304 630A 4-Pole 36kA Ekip LSI Electronic MCCB

1SDX254857R1 ABB EPX-XT5N-E2-6304 630A 4-Pole 36kA Ekip LSI Electronic MCCB

ABB EPX-XT5N-E2-6304 is a 630 A four-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring an Ekip LSI trip unit with long-time, short-time and instantaneous protection for high-current low-voltage electrical distribution systems.

SKU: 1SDX254857R1Alt SKU: EPX-XT5N-E2-6304MPN: 1SDX254857R1
Price
List Price £3,240.00 ex VAT
Your Price (ex VAT)
£3,240.00
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,240.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,240.00

Why Choose the ABB EPX-XT5N-E2-6304 630A 4-Pole MCCB?

The ABB EPX-XT5N-E2-6304 is a high-performance 630 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT5N 630 A platform, combining robust construction with advanced electronic protection technology for commercial buildings, industrial facilities and electrical distribution assemblies.

Equipped with an ABB Ekip LSI electronic trip unit, the EPX-XT5N-E2-6304 provides three essential protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These electronic protection characteristics enable electrical engineers to configure suitable trip settings, coordinate protective devices and support reliable operation within demanding low-voltage distribution networks.

With a rated current of 630 A, a four-pole configuration and a specified 36 kA short-circuit breaking capacity, this MCCB is suitable for protecting high-current three-phase distribution feeders incorporating a neutral conductor. Its 190 mm-wide XT5 frame supports integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, switchboard manufacturers and maintenance engineers requiring advanced electronic circuit protection.

Key Advantages

  • 630 A rated current: Suitable for protecting high-current low-voltage electrical distribution circuits.
  • Four-pole construction: Provides coordinated switching of three phase conductors and a neutral conductor.
  • 36 kA breaking capacity: Offers substantial short-circuit interruption capability under the applicable rated conditions.
  • Advanced Ekip LSI electronic protection: Incorporates long-time, short-time and instantaneous protection characteristics.
  • Adjustable overload protection: Supports coordination of protection settings with cable ratings and installation requirements.
  • Short-time delayed protection: Helps achieve selective coordination with downstream protective devices where the electrical system design permits.
  • Instantaneous short-circuit protection: Provides rapid interruption when high-current faults exceed the configured threshold.
  • Electronic trip technology: Offers greater protection flexibility than conventional thermal-magnetic MCCBs.
  • ABB Tmax XT5N platform: Uses established ABB circuit breaker technology for dependable high-current electrical protection.
  • Four-pole isolation: Supports electrical maintenance procedures requiring simultaneous switching of phase and neutral conductors.
  • Protecta Power integration: Designed for use with appropriately selected ABB Protecta Power distribution assemblies.
  • Robust moulded case construction: Suitable for demanding commercial and industrial electrical distribution environments.

Key Features

  • Manufacturer: ABB.
  • Product family: ABB Protecta Power Devices.
  • Circuit breaker platform: ABB SACE Tmax XT5N.
  • Rated current: 630 A.
  • Number of poles: 4.
  • Specified short-circuit breaking capacity: 36 kA.
  • Electronic trip unit: ABB Ekip LSI.
  • L function: Long-time overload protection against sustained excessive current.
  • S function: Short-time delayed short-circuit protection supporting protective device coordination.
  • I function: Instantaneous short-circuit protection for rapid interruption of high-current faults.
  • Protection configuration: L, S and I characteristics incorporated within the electronic trip system.
  • Frame designation: XT5N 630.
  • Frame current class: 630 A.
  • Nominal device width: 190 mm.
  • Four-pole switching: Suitable for appropriately designed three-phase systems incorporating a neutral conductor.
  • Operating mechanism: Manual front-operated circuit breaker mechanism.
  • Trip indication: Operating mechanism indicates a tripped condition.
  • Accessory compatibility: Supports appropriately selected ABB Tmax XT5 mounting, connection and operating accessories.
  • Product family standard: IEC/EN 60947-2.

Reliable Ekip LSI Electronic Protection for High-Current Distribution

The ABB EPX-XT5N-E2-6304 uses electronic current monitoring to protect electrical circuits against abnormal operating conditions. Its long-time (L) protection responds to sustained overloads that could otherwise cause excessive cable temperatures or damage connected equipment. The short-time (S) protection introduces a controlled delay for selected short-circuit conditions, supporting coordination with downstream protective devices. The instantaneous (I) protection provides rapid circuit interruption when high-current faults exceed the configured protection threshold.

A significant advantage of the ABB Ekip LSI trip unit is that all three protection characteristics are available within the same electronic protection system. Unlike LS/I configurations, where short-time and instantaneous protection are selected as alternatives, LSI protection incorporates both functions. This provides greater flexibility when configuring circuit protection and can help improve selectivity, minimise unnecessary upstream interruptions and support effective fault management in appropriately engineered electrical distribution networks.

The ABB SACE Tmax XT5N platform combines these electronic protection capabilities with robust moulded case construction suitable for higher-current electrical distribution. Its four-pole configuration supports coordinated switching of three phase conductors and a neutral conductor, while its 630 A rating makes it suitable for substantial distribution feeders. Correct selection of trip settings, cable ratings, neutral protection requirements, operating voltage, prospective short-circuit current and protective device coordination remains essential for safe and reliable operation.

Typical Applications

  • ABB Protecta Power distribution boards: High-current electronic protection for compatible distribution assemblies.
  • Commercial electrical distribution: Main and outgoing feeder protection in large commercial buildings.
  • Industrial switchboards: Protection of high-current three-phase distribution circuits.
  • Main distribution boards: Protection of substantial outgoing feeders and electrical distribution circuits.
  • Sub-distribution systems: Four-pole protection for circuits incorporating a neutral conductor.
  • Building services: Electrical distribution for large mechanical plant, ventilation and cooling systems.
  • Manufacturing facilities: Protection of appropriately designed industrial electrical supply circuits.
  • Commercial infrastructure: Power distribution in warehouses, hospitals, educational facilities and public buildings.
  • Coordinated electrical networks: Installations requiring long-time, short-time and instantaneous protection functions.
  • Switchboard manufacturing: Distribution assemblies designed around the ABB SACE Tmax XT5 circuit breaker platform.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT5
Product model EPX-XT5N-E2-6304
ABB order code 1SDX254857R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT5N 630
Frame current class 630 A
Rated current (In) 630 A
Number of poles 4
Specified short-circuit breaking capacity 36 kA
Trip unit technology Electronic
Trip unit ABB Ekip LSI
Long-time protection (L) Overload protection
Short-time protection (S) Delayed short-circuit protection
Instantaneous protection (I) Instantaneous short-circuit protection
Protection characteristics LSI
Electrical system Low-voltage AC distribution
Phase configuration Three-phase with neutral
Nominal device width 190 mm
Operating mechanism Manual circuit breaker operation
Primary function Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer installation requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT5N-E2-6304 used for?

The ABB EPX-XT5N-E2-6304 is a 630 A four-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards, commercial electrical systems and industrial switchgear assemblies.

What is the rated current of the EPX-XT5N-E2-6304?

The EPX-XT5N-E2-6304 has a 630 A rated current and uses the ABB SACE Tmax XT5N 630 A frame platform. It is intended for appropriately designed high-current electrical distribution circuits requiring electronic protection.

What is the breaking capacity of this ABB MCCB?

The circuit breaker has a specified 36 kA short-circuit breaking capacity. The applicable rated operating voltage, manufacturer short-circuit rating conditions and installation prospective fault current must be checked when selecting the device.

What does Ekip LSI electronic protection mean?

Ekip LSI is an electronic trip system incorporating long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide adjustable protection characteristics for low-voltage electrical distribution applications.

What is the difference between Ekip LSI and Ekip LS/I?

Ekip LSI incorporates long-time, short-time and instantaneous protection characteristics within the same electronic trip system. Ekip LS/I provides long-time protection together with a choice between short-time and instantaneous protection. LSI therefore offers additional flexibility when coordinating protective devices.

What does the four-pole configuration mean?

The four-pole (4P) configuration provides coordinated switching of three phase conductors and a neutral conductor. This makes the breaker suitable for appropriately designed three-phase electrical distribution systems requiring four-pole switching and isolation. Neutral protection settings should be verified for the selected circuit breaker configuration.

What is the installation width of the EPX-XT5N-E2-6304?

The ABB Protecta Power XT5 four-pole circuit breaker format has a 190 mm nominal width. Installation space must also account for the correct mounting arrangement, cable terminations, electrical clearances and any required accessories. For XT5 outgoing devices, ABB recommends considering a side cableway extension box where additional space is needed for larger cables.

Can the EPX-XT5N-E2-6304 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT5N-E2-6304 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The appropriate XT5 mounting arrangement, electrical connections, cable accommodation, enclosure compatibility and electronic protection settings should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining adjustable electronic trip functionality, robust construction and dependable overload and short-circuit protection for modern high-current low-voltage power systems.