Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT5N-E2-4004 is a 400 A four-pole SACE Tmax XT5N400 moulded case circuit breaker with 36 kA breaking capacity and Ekip Dip LSI electronic overload, short-time and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£2,204.40
The ABB EPX-XT5N-E2-4004 is a high-performance 400 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB SACE Tmax XT5N400 platform with an Ekip Dip LSI electronic trip unit, delivering configurable circuit protection for higher-capacity electrical distribution assemblies.
Featuring a 36 kA short-circuit breaking capacity, the EPX-XT5N-E2-4004 helps protect electrical conductors, switchgear and connected equipment against potentially damaging fault currents. Its electronic trip unit incorporates long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I), providing flexibility for protective device coordination throughout low-voltage electrical installations.
With a 400 A rated current and four-pole configuration, this MCCB is particularly suitable for high-capacity three-phase distribution circuits requiring four-pole switching. Its robust ABB Tmax XT5N construction, electronic protection technology and compatibility with appropriately configured ABB Protecta Power distribution boards make it a practical solution for electrical contractors, panel builders and maintenance engineers.
The ABB EPX-XT5N-E2-4004 incorporates an Ekip Dip LSI electronic trip unit designed to protect higher-current electrical distribution circuits against sustained overloads and short-circuit faults. Electronic protection technology uses current sensing and electronic processing to deliver defined protective characteristics, helping electrical designers achieve suitable protection coordination throughout low-voltage distribution systems.
The L (long-time) protection function responds to sustained excessive current, helping prevent overheating of electrical conductors and connected equipment. The S (short-time) protection function provides delayed short-circuit protection, which can support selectivity with downstream protective devices. The I (instantaneous) protection function responds rapidly to high short-circuit currents, helping minimise the duration of severe electrical faults.
Unlike an LS/I trip unit, which offers a choice between short-time and instantaneous protection, the Ekip Dip LSI arrangement incorporates all three L, S and I protection functions. This provides additional flexibility when coordinating protection across multiple levels of an electrical distribution network, subject to the available settings and the overall system design.
The four-pole construction supports installations where three phase conductors and a neutral conductor must be switched together. This arrangement is particularly useful in compatible three-phase and neutral distribution systems. The neutral pole's protection characteristics and suitability must be verified for the specific circuit breaker configuration and installation requirements.
The ABB SACE Tmax XT5N400 platform provides a robust solution for electrical circuits requiring a 400 A protective device. Its moulded case construction supports installation within appropriately designed commercial and industrial switchboards. Sufficient space must be provided for power connections, cable bending radii, terminal protection and any selected operating accessories.
When installing the EPX-XT5N-E2-4004 within an ABB Protecta Power distribution board, appropriate mounting components, terminal connections, cable routing arrangements and protective covers must be selected. Electrical designers should verify prospective fault current, conductor ratings, neutral arrangements, electronic trip settings and protective device coordination before commissioning.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | SACE Tmax XT |
| Circuit breaker frame | XT5 |
| Performance level | XT5N |
| Frame configuration | XT5N400 |
| ABB order code | 1SDX254854R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 400 A |
| Maximum frame rating | 400 A |
| Number of poles | 4P (four pole) |
| Short-circuit breaking capacity | 36 kA |
| Trip unit | Ekip Dip LSI |
| Trip technology | Electronic |
| Overload protection | L – long-time protection |
| Short-time protection | S – short-time delayed short-circuit protection |
| Instantaneous protection | I – instantaneous short-circuit protection |
| Protection configuration | LSI – long-time, short-time and instantaneous functions |
| Rated frequency | 50/60 Hz |
| Applicable standard | IEC 60947-2 |
| Installation type | Electrical distribution board / switchboard mounting |
| Compatible system | ABB Protecta Power |
| Product category | Protecta Power Devices |
The ABB EPX-XT5N-E2-4004 is a 400 A four-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using an Ekip Dip LSI electronic trip unit.
The EPX-XT5N-E2-4004 has a 400 A rated current and uses the ABB SACE Tmax XT5N400 platform, which has a maximum frame rating of 400 A. The circuit breaker is therefore specified at the maximum current rating of its frame.
The EPX-XT5N-E2-4004 is specified with a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.
LSI identifies an electronic protection arrangement incorporating L (long-time overload protection), S (short-time delayed short-circuit protection) and I (instantaneous short-circuit protection). These functions provide configurable protection characteristics for low-voltage electrical distribution systems.
Ekip Dip LSI incorporates long-time, short-time delayed and instantaneous protection functions together. Ekip LS/I provides long-time overload protection with a choice between short-time delayed or instantaneous short-circuit protection. The LSI arrangement offers additional flexibility for protective device coordination.
Both circuit breakers use the ABB SACE Tmax XT5N400 four-pole platform and feature 36 kA breaking capacity with LSI electronic protection. The EPX-XT5N-E2-3204 has a rated current of 320 A, while the EPX-XT5N-E2-4004 has a rated current of 400 A.
Yes. Its four-pole configuration supports simultaneous switching of three phase conductors and a neutral conductor in compatible electrical installations. The neutral protection arrangement, earthing system and applicable installation requirements must be verified before selection.
Yes. The EPX-XT5N-E2-4004 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT5 mounting components, terminal connections, protective covers and installation accessories must be selected according to the switchboard configuration. Additional cableway space may be appropriate for larger outgoing conductors.
ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT5N-E2-4004 combines a 400 A four-pole XT5N400 circuit breaker with 36 kA breaking capacity and Ekip Dip LSI electronic protection, delivering a robust and configurable solution for compatible ABB Protecta Power distribution assemblies.