1SDX254852R1 ABB EPX-XT5N-E2-2504 250A 4P 36kA MCCB - LSI

1SDX254852R1 ABB EPX-XT5N-E2-2504 250A 4P 36kA MCCB – LSI

ABB EPX-XT5N-E2-2504 is a 250 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and an Ekip Dip LSI electronic trip unit, providing adjustable long-time overload, short-time delayed and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254852R1Alt SKU: EPX-XT5N-E2-2504MPN: 1SDX254852R1
Price
List Price £2,099.44 ex VAT
Your Price (ex VAT)
£2,099.44
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,099.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,099.44

Why Choose the ABB EPX-XT5N-E2-2504 250A 4-Pole MCCB?

The ABB EPX-XT5N-E2-2504 is a high-performance 250 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and an advanced Ekip Dip LSI electronic trip unit, this circuit breaker forms part of the ABB Protecta Power Devices range and incorporates ABB's established SACE Tmax XT5N circuit breaker technology.

Designed for installations requiring flexible electronic protection, the EPX-XT5N-E2-2504 combines a robust moulded case construction with configurable long-time, short-time delayed and instantaneous overcurrent protection. Its LSI protection system allows electrical designers to configure protection characteristics according to the operating requirements of the installation, supporting appropriate cable protection and coordination with upstream and downstream circuit breakers.

With a 250 A rated current, four-pole configuration and 36 kA breaking capacity, the ABB EPX-XT5N-E2-2504 is particularly suitable for three-phase distribution circuits where simultaneous switching of the phase conductors and neutral is required. Supplied under ABB order code 1SDX254852R1, this electronic-trip MCCB provides a versatile circuit protection solution for compatible ABB Protecta Power distribution boards, commercial switchgear and industrial electrical panels.

Key Advantages

  • 250 A rated current provides dependable protection for appropriately rated three-phase electrical distribution circuits.
  • Four-pole (4P) configuration supports simultaneous switching of three phase conductors and a neutral conductor where applicable.
  • 36 kA short-circuit breaking capacity supports installations with substantial prospective fault currents.
  • Ekip Dip LSI electronic trip unit provides configurable overload and short-circuit protection.
  • Long-time overload protection (L) helps protect conductors and connected equipment against sustained excessive current.
  • Short-time delayed protection (S) supports protective device coordination and discrimination.
  • Instantaneous protection (I) provides rapid interruption during high-current short circuits.
  • Separate L, S and I protection functions offer greater configuration flexibility than LS/I releases with selectable S or I operation.
  • Electronic trip technology allows protection characteristics to be configured for different circuit requirements.
  • Front-accessible DIP-switch settings provide practical adjustment of electronic protection parameters.
  • ABB SACE Tmax XT5N construction combines robust circuit protection with a compact moulded case design.
  • 190 mm nominal four-pole width supports planned integration into compatible electrical distribution assemblies.
  • XT5N 400 A frame platform provides the mechanical basis for the 250 A electronic protection configuration.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for installations requiring four-pole switching and configurable electronic overcurrent protection.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT5N moulded case circuit breaker platform.
  • 250 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA short-circuit breaking capacity under the applicable rated operating conditions.
  • Ekip Dip LSI electronic protection release.
  • Long-time overload protection (L) with configurable electronic settings.
  • Short-time delayed short-circuit protection (S) for protection coordination.
  • Instantaneous short-circuit protection (I) for rapid fault interruption.
  • Separate L, S and I protection characteristics for flexible circuit protection.
  • Electronic overcurrent sensing rather than conventional thermal-magnetic trip technology.
  • Front-accessible DIP switches for electronic protection adjustments.
  • Trip-unit indications to assist commissioning, inspection and maintenance.
  • XT5N 400 A frame family with a 250 A rated electronic release.
  • Four-pole construction for appropriately designed three-phase and neutral distribution arrangements.
  • Fixed-mounted circuit breaker platform for compatible electrical distribution assemblies.
  • Front-terminal connection arrangement on the corresponding XT5N Ekip Dip LSI breaker.
  • 190 mm nominal four-pole device width in the ABB Protecta Power XT5 range.
  • Manual toggle-operated switching mechanism.
  • Designed in accordance with IEC/EN 60947-2.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • ABB manufacturer order code: 1SDX254852R1.

Advanced 250A Four-Pole Electronic Circuit Protection with Ekip LSI Technology

The ABB EPX-XT5N-E2-2504 combines the mechanical switching and fault-interruption capabilities of an ABB SACE Tmax XT5N MCCB with the configurable protection characteristics of an Ekip Dip LSI electronic trip unit. This combination enables the circuit breaker to respond to overload and short-circuit conditions according to selected protective thresholds and operating characteristics, helping safeguard electrical cables, connected equipment and distribution infrastructure.

The long-time protection function (L) responds to sustained overload conditions. Adjustable electronic settings allow the protective response to be matched to the electrical installation's expected load, conductor ratings and design requirements. This helps reduce the risk of thermal damage caused by prolonged excessive current while supporting dependable operation of the protected distribution circuit.

The short-time protection function (S) provides a configurable response to short-circuit currents with an intentional delay where appropriate. This function is particularly valuable in distribution systems where protective device selectivity is important. By coordinating upstream and downstream circuit breakers, electrical designers can help minimise unnecessary disconnection of unaffected circuits when a downstream fault occurs. Actual discrimination must be confirmed using ABB's published coordination data and the installation's prospective fault-current calculations.

The instantaneous protection function (I) provides rapid interruption when the current reaches the selected instantaneous trip threshold. This helps limit the duration of high-current short circuits. Unlike an Ekip LS/I release, which offers a choice between short-time delayed and instantaneous protection modes, the Ekip LSI configuration provides separate long-time, short-time delayed and instantaneous protection characteristics for adjustment.

The ABB SACE Tmax XT5N 400 A frame platform provides a robust mechanical foundation for the 250 A electronic trip configuration. Although the XT5N frame is rated at 400 A, the EPX-XT5N-E2-2504 is a 250 A rated protective device. The mechanical frame rating must not be confused with the rated current of the electronic trip unit or the allowable current of the protected circuit.

The four-pole construction enables simultaneous switching of four conductors, typically three phase conductors and a neutral conductor in an appropriately designed three-phase distribution system. This arrangement can be useful where neutral isolation is required by the electrical design. However, four-pole switching does not automatically mean that the neutral conductor has the same overcurrent protection arrangement as the phase conductors. The neutral-pole protection configuration must be confirmed against the applicable ABB technical documentation.

For ABB Protecta Power distribution assemblies, the XT5 platform provides a high-current outgoing circuit solution with a 190 mm nominal four-pole width. ABB's Protecta Power installation guidance also recommends considering a side cableway extension box for XT5 outgoing devices where larger conductors require additional wiring space. Correct selection of cable terminations, mounting accessories and enclosure arrangements is essential for dependable installation.

The EPX-XT5N-E2-2504 offers a specified 36 kA short-circuit breaking capacity. This rating must be checked against the installation's operating voltage and prospective fault current before selection. The standard LSI electronic release provides overload and short-circuit protection rather than residual-current or earth-leakage protection, so any required additional protective functions must be specified separately.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 250 A electronic overcurrent protection.
  • Four-pole distribution circuits requiring simultaneous phase and neutral switching.
  • Commercial building main and sub-distribution assemblies.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Building services and mechanical plant power distribution.
  • Electrical installations requiring adjustable long-time overload protection.
  • Distribution systems where short-time delayed protection supports selective coordination.
  • Installations requiring separate long-time, short-time and instantaneous protection characteristics.
  • Electrical refurbishment and distribution board upgrades involving compatible ABB MCCBs.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT5 / Protecta Power
ABB order code 1SDX254852R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 250 A
Number of poles 4
Pole configuration 4P
Short-circuit breaking capacity 36 kA
Breaking capacity classification N (normal breaking capacity)
Trip unit type Ekip Dip LSI electronic
Protection technology Electronic overcurrent release
Long-time protection (L) Adjustable overload protection
Long-time protection characteristic Electronic inverse-time overload protection
Short-time protection (S) Adjustable delayed short-circuit protection
Instantaneous protection (I) Adjustable instantaneous short-circuit protection
Protection configuration L, S and I functions
Protection adjustment method Front-mounted DIP switches
Trip-unit indications Electronic status and protection indications
Frame family XT5N
Frame rating 400 A
Rated electronic release current 250 A
Nominal four-pole width 190 mm
Rated operational voltage (XT5N family) Up to 690 V AC
Rated insulation voltage (XT5N family) 1,000 V
Rated impulse withstand voltage (XT5N family) 8 kV
Mounting configuration Fixed-mounted MCCB platform
Terminal configuration Front terminals on the corresponding XT5N configuration
Applicable circuit breaker standard IEC/EN 60947-2
Application Low-voltage electrical distribution
Installation type Compatible electrical distribution board / switchgear assembly
Operating mechanism Manual toggle-operated circuit breaker
Typical electrical system Three-phase AC distribution with four-pole switching

Frequently Asked Questions

What is the ABB EPX-XT5N-E2-2504 used for?

The ABB EPX-XT5N-E2-2504 is a 250 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LSI electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT5N-E2-2504?

The EPX-XT5N-E2-2504 has a 250 A rated current. Its electronic trip unit provides adjustable protection characteristics for appropriately designed electrical distribution circuits.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT5N-E2-2504 has a specified 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the circuit breaker.

What does Ekip LSI mean?

Ekip LSI is an electronic trip unit providing three protection characteristics: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions allow the circuit breaker to be configured for different overload and fault-current conditions.

What is the difference between Ekip LSI and Ekip LS/I?

An Ekip LSI trip unit includes long-time, short-time delayed and instantaneous protection characteristics for adjustment. An Ekip LS/I trip unit provides long-time protection together with a choice between short-time delayed or instantaneous short-circuit protection. The LSI configuration offers greater flexibility where separate S and I protection functions are required.

Can the overload protection setting be adjusted?

Yes. The Ekip LSI electronic trip unit provides adjustable long-time overload protection. The appropriate setting must be selected according to the manufacturer's specified adjustment range, conductor ratings, expected load current and electrical installation requirements.

Can short-time and instantaneous protection be configured separately?

Yes. The Ekip LSI configuration provides separate short-time delayed (S) and instantaneous (I) protection characteristics. This allows the protective response to be configured for the installation's short-circuit conditions and coordination requirements, subject to the available ABB trip-unit settings.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables simultaneous switching of four conductors, typically the three phase conductors and a neutral conductor in a three-phase distribution system. This makes the MCCB suitable for installations requiring four-pole switching, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.

What is the difference between the 250A trip rating and the 400A frame rating?

The 250 A trip rating identifies the circuit breaker's rated protective current, while the 400 A frame rating identifies the maximum current rating of the XT5N frame platform used for this configuration. The EPX-XT5N-E2-2504 is a 250 A protective device and must not be treated as a 400 A rated circuit breaker.

Does the ABB EPX-XT5N-E2-2504 provide earth-leakage protection?

The standard Ekip LSI electronic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.

What is the ABB order code for the EPX-XT5N-E2-2504?

The ABB manufacturer order code is 1SDX254852R1. The corresponding product reference is EPX-XT5N-E2-2504, identifying the 250 A, four-pole, 36 kA electronic-trip MCCB with Ekip LSI protection within the ABB Protecta Power Devices range.

Trusted ABB Electronic Circuit Protection for Professional Installations

ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with configurable electronic protection. The EPX-XT5N-E2-2504 delivers dependable 250 A four-pole circuit protection, a 36 kA short-circuit breaking capacity and comprehensive Ekip LSI functionality for appropriately specified commercial and industrial low-voltage electrical distribution systems.