1SDX254848R1 ABB EPX-XT5N-E2-3203 320A 3-Pole 36kA Ekip Dip LSI MCCB

1SDX254848R1 ABB EPX-XT5N-E2-3203 320A 3-Pole 36kA Ekip Dip LSI MCCB

ABB EPX-XT5N-E2-3203 is a 320 A three-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 36 kA short-circuit breaking capacity and an Ekip Dip LSI electronic trip unit providing long-time, short-time and instantaneous protection for low-voltage electrical distribution systems.

SKU: 1SDX254848R1Alt SKU: EPX-XT5N-E2-3203MPN: 1SDX254848R1
Price
List Price £1,667.12 ex VAT
Your Price (ex VAT)
£1,667.12
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,667.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,667.12

Why Choose the ABB EPX-XT5N-E2-3203 320A 3-Pole MCCB?

The ABB EPX-XT5N-E2-3203 is a high-performance 320 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the established ABB SACE Tmax XT5N400 platform, providing dependable protection for commercial, industrial and infrastructure electrical installations.

Equipped with an ABB Ekip Dip LSI electronic trip unit, the EPX-XT5N-E2-3203 provides three essential protection functions: long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I). Its electronic protection technology allows trip characteristics to be configured according to installation requirements, supporting selective coordination and helping protect distribution cables, switchgear and connected electrical equipment.

With a 320 A rated current, three-pole construction and 36 kA short-circuit breaking capacity, this MCCB is suitable for three-phase low-voltage distribution applications. Its robust XT5N400 frame supports integration into compatible ABB Protecta Power distribution assemblies, industrial switchboards and electrical distribution panels requiring advanced electronic circuit protection.

Key Advantages

  • 320 A rated current for high-current commercial and industrial distribution circuits.
  • Three-pole configuration designed for three-phase electrical systems.
  • 36 kA breaking capacity for dependable short-circuit fault interruption.
  • ABB Ekip Dip LSI electronic trip unit provides comprehensive overload and short-circuit protection.
  • Long-time overload protection (L) helps protect electrical cables and connected equipment against sustained excessive current.
  • Short-time protection (S) supports time-delayed fault clearance and coordination with downstream protective devices.
  • Instantaneous protection (I) provides rapid interruption of severe short-circuit faults.
  • Configurable electronic protection settings support installation-specific protection requirements.
  • ABB Tmax XT5N400 frame offers a robust platform for industrial power distribution.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial buildings, manufacturing facilities and industrial infrastructure.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT5N400 moulded case circuit breaker platform.
  • 320 A rated electronic trip unit current.
  • Three-pole (3P) construction.
  • 36 kA rated short-circuit breaking capacity.
  • Ekip Dip LSI electronic protection unit.
  • Long-time (L) protection against sustained overload conditions.
  • Short-time (S) protection for short-circuit faults with intentional time-delay functionality.
  • Instantaneous (I) protection for rapid interruption of high-current faults.
  • Adjustable electronic protection characteristics for circuit coordination.
  • XT5N400 frame with a maximum frame rating of 400 A.
  • Three-pole switching and protection for three-phase circuits.
  • Manual operating mechanism with circuit breaker trip indication.
  • Designed for use in compatible low-voltage electrical distribution assemblies.
  • Compatible with appropriately selected ABB Tmax XT5 installation accessories.

Advanced LSI Electronic Protection for Industrial Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT5N-E2-3203 protect electrical installations by automatically interrupting current when overload or short-circuit faults occur. The integrated Ekip Dip LSI electronic trip unit provides long-time protection against sustained overloads, short-time protection for coordinated fault clearance and instantaneous protection for rapid interruption of severe short circuits. These functions help protect electrical distribution cables, connected equipment and downstream circuits.

The ABB SACE Tmax XT5 circuit breaker family is developed for dependable performance in modern low-voltage electrical distribution systems. Its robust construction and electronic protection technology support integration into industrial switchboards, commercial distribution panels and compatible ABB Protecta Power assemblies. The EPX-XT5N-E2-3203 is particularly suited to installations requiring 320 A three-pole circuit protection and a 36 kA short-circuit breaking rating, subject to verification of the installation voltage, prospective fault current, cable characteristics and protection coordination requirements.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Low-voltage main switchboards and sub-distribution panels.
  • Industrial machinery supply circuits and electrical feeders.
  • Manufacturing facilities and industrial production plants.
  • Building services and commercial electrical infrastructure.
  • Warehouses, logistics facilities and large commercial premises.
  • Electrical distribution circuits requiring configurable electronic protection.
  • Industrial electrical installations requiring coordinated LSI protection.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT5N400
ABB order code 1SDX254848R1
ABB circuit breaker reference 1SDA100357R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 320 A
Number of poles 3
Short-circuit breaking capacity 36 kA
Trip unit Ekip Dip LSI
Trip unit technology Electronic
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Short-circuit protection with time-delay functionality
Instantaneous protection (I) Short-circuit protection without intentional delay
Protection functions L, S and I
Frame family XT5N400
Maximum frame rating 400 A
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT5N-E2-3203 used for?

The ABB EPX-XT5N-E2-3203 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial three-phase electrical distribution systems requiring electronic circuit protection.

What is the rated current of the EPX-XT5N-E2-3203?

The circuit breaker has a 320 A rated current and uses the ABB Tmax XT5N400 frame, which has a maximum frame rating of 400 A. Its Ekip Dip LSI electronic trip unit provides configurable protection characteristics for appropriately designed electrical distribution circuits.

What is the breaking capacity of this MCCB?

The EPX-XT5N-E2-3203 has a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be verified against the installation's operating voltage and prospective short-circuit current before selecting the circuit breaker.

What protection does the Ekip Dip LSI electronic trip unit provide?

The ABB Ekip Dip LSI electronic trip unit provides three protection functions: long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I). These functions support configurable fault protection and coordination between protective devices in electrical distribution systems.

Where is the ABB EPX-XT5N-E2-3203 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where three-pole electronic circuit protection is required. Suitable mounting arrangements, connections and installation accessories should be selected according to the electrical distribution assembly design.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT5N-E2-3203 combines a 320 A rating, three-pole construction, 36 kA breaking capacity and advanced Ekip Dip LSI electronic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.