ABB EPX-XT5N-E2-2503 (1SDX254847R1) is a 250 A three-pole SACE Tmax XT5N400 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip Dip LSI electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection for three-phase outgoing circuits.
£1,786.22
The ABB EPX-XT5N-E2-2503 is a high-performance 250 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Built around the established ABB SACE Tmax XT5N400 circuit breaker platform, this electronic MCCB combines robust construction with configurable protection technology for demanding electrical distribution applications.
As part of the ABB Protecta Power Devices product group, the EPX-XT5N-E2-2503 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its ABB Ekip Dip LSI electronic trip configuration provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. These three functions enable electrical engineers to develop coordinated protection strategies for appropriately designed low-voltage power distribution networks.
Featuring a 250 A rated current, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT5N-E2-2503 is suitable for three-phase outgoing feeders, industrial distribution panels and commercial electrical installations. Its 140 mm nominal device width supports efficient integration into compatible distribution assemblies while providing the protection capabilities associated with the ABB XT5 platform.
Identified by ABB order code 1SDX254847R1, this circuit breaker offers electrical contractors, consulting engineers, panel builders and facilities managers a clearly specified 250A 3P 36kA LSI electronic MCCB for use in compatible ABB Protecta Power electrical distribution systems.
The ABB EPX-XT5N-E2-2503 250 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers provide automatic interruption when defined abnormal current conditions occur, helping protect electrical cables, distribution equipment and connected loads against the potentially damaging effects of overloads and short circuits.
The electronic trip technology distinguishes this device from conventional thermal-magnetic MCCBs. The ABB Ekip Dip LSI release evaluates current conditions electronically and initiates tripping according to its configured protection characteristics. This provides additional flexibility for electrical engineers responsible for protective device selection, coordination and distribution system design.
The long-time protection function (L) responds to sustained overload conditions. Excessive current flowing through an electrical conductor over time can cause overheating and deterioration of insulation. Correctly configured long-time protection helps safeguard the protected circuit by initiating tripping when current and duration exceed the selected protective characteristics.
The short-time protection function (S) provides delayed operation under defined short-circuit conditions. This function can be valuable in distribution networks containing several protective devices connected in series. Where the overall protection design permits, a suitably configured short-time delay can help a downstream circuit breaker clear a fault before an upstream protective device operates.
The instantaneous protection function (I) provides rapid operation when current reaches the applicable instantaneous threshold. This helps limit the duration of severe short-circuit conditions and complements the overload and short-time protection functions.
Together, the L, S and I protection functions provide a comprehensive electronic overcurrent protection arrangement. The EPX-XT5N-E2-2503 is therefore suitable for appropriately engineered three-phase distribution circuits where adjustable protective characteristics and reliable fault interruption are required.
When specifying an electronic MCCB, the trip unit designation is an important part of the selection process. The LSI designation identifies a release incorporating long-time, short-time and instantaneous overcurrent protection functions.
Long-time protection addresses sustained overload conditions, short-time protection provides a delayed response to defined short-circuit conditions, and instantaneous protection provides rapid operation when current reaches a higher fault threshold. This combination allows engineers to develop protection settings suited to the characteristics of the circuit and the wider distribution network.
The distinction between LSI and LS/I is particularly important. An LSI release provides long-time, short-time and instantaneous protection functions together, whereas an LS/I release provides long-time protection with a choice between short-time and instantaneous short-circuit protection modes.
For installations where several circuit breakers operate in series, the availability of short-time and instantaneous functions can provide useful coordination flexibility. However, actual selectivity depends on the selected settings, prospective fault current and protective device combination. Coordination performance should always be confirmed using the relevant ABB technical data.
The three-pole configuration of the ABB EPX-XT5N-E2-2503 enables coordinated switching and protection of three phase conductors. This makes the breaker suitable for appropriately designed three-phase distribution systems where a dedicated switched neutral pole is not required.
Three-pole MCCBs are widely used in commercial and industrial distribution networks, including outgoing feeders, sub-distribution circuits and electrical panels supplying three-phase equipment. Their suitability depends on the electrical system design, earthing arrangement, conductor configuration and applicable installation regulations.
Because the EPX-XT5N-E2-2503 is a 3P device, it does not provide a fourth pole for neutral switching. Where the installation requires coordinated disconnection of a neutral conductor, an appropriately specified four-pole circuit breaker should be considered instead.
The ABB XT5 three-pole platform has a nominal width of 140 mm, supporting practical integration into compatible electrical distribution assemblies. For XT5 outgoing devices, sufficient cable termination space should also be considered, particularly where larger conductors are required. Appropriate ABB cableway extension arrangements may be useful depending on the assembly design.
The EPX-XT5N-E2-2503 is based on the ABB SACE Tmax XT5N400 platform. This means the device uses an XT5N400 circuit breaker frame while providing a specified 250 A rated current through its fitted electronic protection arrangement.
It is important to distinguish between the 400 A frame rating and the 250 A rated current of the selected breaker. The frame rating identifies the mechanical and electrical platform, while the rated current and trip release characteristics define the protection specified for the outgoing circuit.
The XT5 platform is suitable for distribution applications requiring a robust MCCB construction and electronic trip functionality. Its use within compatible ABB Protecta Power assemblies provides electrical designers with a clearly identified circuit breaker option for higher-current three-phase outgoing feeders.
When planning an installation, engineers should verify the selected device dimensions, cable connection requirements, mounting arrangements and compatibility with the relevant ABB distribution board configuration.
The 250 A rated current of the ABB EPX-XT5N-E2-2503 makes it suitable for circuits designed to operate within the current-carrying and protection capabilities of the device. Correct selection requires consideration of the circuit load, conductor sizing, installation conditions and electronic trip settings.
The specified 36 kA short-circuit breaking capacity is another essential selection parameter. The prospective short-circuit current at the point of installation must be assessed, and the applicable circuit breaker breaking capacity must be confirmed for the system operating voltage. The specified 36 kA rating should not be assumed to apply identically under every electrical condition.
Electrical designers should also assess the required level of selectivity between upstream and downstream protective devices. Although the LSI electronic release offers configurable protection characteristics, discrimination and back-up protection performance must be established using the relevant ABB coordination documentation.
For installations using ABB Protecta Power distribution equipment, the EPX-XT5N-E2-2503 provides a clearly identified three-pole electronic MCCB option. Appropriate mounting components, terminals, conductor connections, cableway space and assembly compatibility should be verified before installation and commissioning.
| Product group | Protecta Power Devices |
|---|---|
| Product range | SACE Tmax XT |
| Circuit breaker platform | XT5N400 |
| Model / SKU | EPX-XT5N-E2-2503 |
| ABB order code | 1SDX254847R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 250 A |
| Frame rating | 400 A |
| Short-circuit breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 3 |
| Pole configuration | Three-pole (3P) |
| Trip unit designation | Ekip Dip LSI |
| Trip technology | Electronic |
| Protection designation | LSI |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Delayed short-circuit protection |
| Instantaneous protection (I) | Instantaneous short-circuit protection |
| Protection arrangement | Long-time, short-time and instantaneous overcurrent protection |
| Electronic trip adjustment | Refer to the fitted ABB Ekip Dip LSI release documentation |
| Neutral switching | No dedicated switched neutral pole |
| Applicable circuit breaker standard | IEC 60947-2 |
| Nominal device width | 140 mm |
| Installation type | Fixed installation within a compatible distribution assembly |
| Mounting compatibility | ABB Protecta Power, subject to appropriate mounting and connection arrangements |
| Electrical application | Three-phase low-voltage power distribution |
| Typical use | Outgoing feeder and sub-distribution circuit protection |
The ABB EPX-XT5N-E2-2503 is a 250 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an ABB Ekip Dip LSI electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies.
The EPX-XT5N-E2-2503 has a 250 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB SACE Tmax XT5N400 platform, which has a 400 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.
LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to sustained overloads, short-time protection provides delayed short-circuit protection and instantaneous protection provides rapid operation under high fault-current conditions. These functions support configurable circuit protection for appropriately designed electrical distribution systems.
An LSI MCCB incorporates long-time, short-time and instantaneous overcurrent protection functions together. An LS/I MCCB provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. The LSI arrangement offers additional flexibility where both delayed and instantaneous short-circuit protection characteristics are required.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT5 three-pole platform has a nominal width of 140 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design, ABB instructions and applicable electrical regulations.
ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, offering dependable protection for commercial and industrial installations. The ABB EPX-XT5N-E2-2503 combines a 250 A rated current, three-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip Dip LSI electronic protection in a robust device intended for compatible ABB Protecta Power distribution systems.