ABB EPX-XT4N-E2-2504 (1SDX254845R1) is a 250 A four-pole SACE Tmax XT4N250 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip Dip LSI electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection for three-phase outgoing circuits requiring four-pole switching.
£2,262.11
The ABB EPX-XT4N-E2-2504 is a high-performance 250 A four-pole moulded case circuit breaker (MCCB) designed to deliver dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Combining the established ABB SACE Tmax XT4N250 circuit breaker platform with electronic protection technology, this MCCB provides a practical solution for installations requiring substantial current-carrying capability, four-pole switching and configurable protection characteristics.
As part of the ABB Protecta Power Devices product group, the EPX-XT4N-E2-2504 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its ABB Ekip Dip LSI electronic trip unit provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. These three functions support the development of coordinated protection strategies for appropriately designed electrical distribution networks.
Featuring a 250 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, this ABB MCCB is suitable for three-phase outgoing feeders and sub-distribution circuits where switching of the neutral conductor is also required. Its 140 mm nominal width provides a compact installation footprint for a four-pole circuit breaker of this rating.
Identified by ABB order code 1SDX254845R1, the EPX-XT4N-E2-2504 offers electrical contractors, consulting engineers, panel builders and facilities managers a clearly specified 250A 4P 36kA LSI electronic MCCB for use within compatible ABB Protecta Power electrical distribution systems.
The ABB EPX-XT4N-E2-2504 250 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage power distribution systems. Moulded case circuit breakers provide automatic interruption when defined abnormal current conditions occur, helping reduce the risk of damage to electrical conductors, distribution equipment and connected loads.
The electronic protection system distinguishes this device from conventional thermal-magnetic MCCBs. Instead of relying solely on thermal and magnetic trip mechanisms, the ABB Ekip Dip LSI release evaluates current conditions electronically and initiates tripping according to its configured protection settings. This provides additional flexibility for electrical engineers designing and coordinating protective devices within larger distribution systems.
The long-time protection function (L) responds to sustained overload conditions. Excessive current flowing through an electrical conductor over time can cause overheating and deterioration of insulation. Correctly configured long-time protection helps safeguard the protected circuit by initiating tripping when current and duration exceed the selected protective characteristics.
The short-time protection function (S) provides delayed operation under defined short-circuit conditions. This function can be valuable where several protective devices are installed in series and the design requires a downstream breaker to clear a fault before an upstream breaker operates. Actual selectivity depends on the chosen settings, fault levels and device combination, and should be confirmed using the relevant ABB coordination data.
The instantaneous protection function (I) provides rapid operation when current reaches the configured instantaneous threshold. This helps limit the duration of severe short-circuit conditions and complements the overload and short-time protection functions.
Together, the L, S and I functions provide a comprehensive overcurrent protection arrangement. This makes the EPX-XT4N-E2-2504 suitable for electrical distribution projects where configurable protective characteristics are required to accommodate the demands of higher-current three-phase circuits.
When specifying electronic MCCBs, it is important to distinguish between LSI and LS/I trip configurations. Although their names are similar, they describe different arrangements of electronic protection functions.
An LSI electronic trip unit, such as the release specified for the ABB EPX-XT4N-E2-2504, incorporates long-time, short-time and instantaneous protection functions. These functions allow the circuit protection strategy to account for sustained overload conditions, short circuits requiring a delayed response and high-current faults requiring rapid operation.
An LS/I electronic trip unit provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection modes. This is a different protection arrangement and should not be treated as interchangeable with LSI without reviewing the circuit design.
For installations where protective device coordination is important, the availability of both short-time and instantaneous functions can provide useful flexibility. However, the exact adjustment ranges, available operating modes and coordination performance must always be verified against the fitted ABB electronic release documentation.
The four-pole configuration of the ABB EPX-XT4N-E2-2504 supports coordinated switching of three phase conductors and a neutral conductor. This makes the device suitable for appropriately designed three-phase electrical distribution systems where the neutral conductor must be disconnected alongside the phases.
Four-pole MCCBs are commonly specified in commercial and industrial distribution assemblies where the installation design requires switching of all relevant live conductors. Whether neutral disconnection is necessary or permitted depends on the electrical system, earthing arrangement and applicable regulations.
It is essential to distinguish between neutral switching and neutral overcurrent protection. The presence of a fourth pole does not automatically establish that the neutral conductor has the same protection characteristics as the phase conductors. The exact neutral pole arrangement and protection settings should be confirmed using the manufacturer's technical documentation.
The 140 mm nominal width of the ABB XT4 four-pole platform helps panel builders and electrical designers allocate space within compatible distribution assemblies. The combination of four-pole construction, electronic LSI protection and a 250 A rated current makes this MCCB a practical option for appropriately engineered higher-current distribution circuits.
The 250 A rated current of the EPX-XT4N-E2-2504 makes it suitable for circuits designed to operate within the protection and current-carrying capabilities of the device. Correct selection requires assessment of the circuit load, conductor size, installation conditions and protective settings. A higher rated current should not be selected without confirming that the associated cables and equipment are adequately protected.
The specified 36 kA short-circuit breaking capacity is an important selection parameter. The prospective fault current at the installation point must be calculated or otherwise established, and the applicable breaker rating must be checked against the system operating voltage. Breaking capacity can vary with voltage, so the specified 36 kA figure should not be assumed to apply under every electrical condition.
Where several circuit breakers operate within the same distribution system, protection coordination should also be considered. Electronic LSI settings can support a coordinated approach, but discrimination and back-up protection performance must be verified using the relevant ABB data rather than assumed from the trip unit designation alone.
For projects using ABB Protecta Power distribution equipment, the EPX-XT4N-E2-2504 provides a clearly identified four-pole electronic MCCB option. The appropriate mounting arrangements, connection accessories, conductor terminations and assembly compatibility should be confirmed before installation.
| Product group | Protecta Power Devices |
|---|---|
| Product range | SACE Tmax XT |
| Circuit breaker platform | XT4N250 |
| Model / SKU | EPX-XT4N-E2-2504 |
| ABB order code | 1SDX254845R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 250 A |
| Frame rating | 250 A |
| Short-circuit breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Trip unit designation | Ekip Dip LSI |
| Trip technology | Electronic |
| Protection designation | LSI |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Delayed short-circuit protection |
| Instantaneous protection (I) | Instantaneous short-circuit protection |
| Protection arrangement | Long-time, short-time and instantaneous overcurrent protection |
| Electronic trip adjustment | Refer to the fitted ABB Ekip Dip LSI release documentation |
| Neutral switching | Four-pole construction |
| Neutral overcurrent protection | Dependent on the fitted release and neutral pole arrangement |
| Applicable circuit breaker standard | IEC 60947-2 |
| Nominal device width | 140 mm |
| Installation type | Fixed installation within a compatible distribution assembly |
| Mounting compatibility | ABB Protecta Power, subject to appropriate mounting and connection arrangements |
| Electrical application | Three-phase low-voltage distribution with four-pole switching |
| Typical use | Outgoing feeder and sub-distribution circuit protection |
The ABB EPX-XT4N-E2-2504 is a 250 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an ABB Ekip Dip LSI electronic trip unit and is intended for compatible ABB Protecta Power distribution assemblies. Its four-pole construction supports coordinated switching of three phase conductors and a neutral conductor.
The EPX-XT4N-E2-2504 has a 250 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It uses the ABB SACE Tmax XT4N250 platform, which has a 250 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.
LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to sustained overloads, short-time protection provides delayed short-circuit protection and instantaneous protection provides rapid operation under high fault-current conditions. These functions support configurable protection for appropriately designed electrical distribution circuits.
A four-pole LSI MCCB combines coordinated switching of three phase conductors and a neutral conductor with electronic long-time, short-time and instantaneous protection functions. This is useful in three-phase distribution systems where neutral switching and configurable overcurrent protection are required. The neutral overcurrent protection arrangement must be verified separately for the specific breaker configuration.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT4 four-pole platform has a nominal width of 140 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design, ABB instructions and applicable electrical regulations.
ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, offering dependable protection for commercial and industrial installations. The ABB EPX-XT4N-E2-2504 combines a 250 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip Dip LSI electronic protection in a compact device intended for compatible ABB Protecta Power distribution systems.