1SDX254843R1 ABB EPX-XT4N-E2-1604 160A 4-Pole 36kA MCCB Ekip Dip LSI

1SDX254843R1 ABB EPX-XT4N-E2-1604 160A 4-Pole 36kA MCCB Ekip Dip LSI

ABB EPX-XT4N-E2-1604 is a 160 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity at 415 V AC and adjustable Ekip Dip LSI electronic protection, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254843R1Alt SKU: EPX-XT4N-E2-1604MPN: 1SDX254843R1
Price
List Price £1,931.61 ex VAT
Your Price (ex VAT)
£1,931.61
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,931.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,931.61

Why Choose the ABB EPX-XT4N-E2-1604 160A 4-Pole Electronic MCCB?

The ABB EPX-XT4N-E2-1604 is a high-performance 160 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 36 kA short-circuit breaking capacity with advanced Ekip Dip LSI electronic protection, making it a practical choice for installations requiring configurable protective characteristics and coordinated four-pole switching.

Built around the established ABB SACE Tmax XT4N platform, the EPX-XT4N-E2-1604 incorporates an electronic trip unit providing three essential protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions allow electrical designers to configure the circuit breaker according to conductor ratings, connected loads, prospective fault currents and protection coordination requirements.

With its 160 A rated current, four-pole configuration and compact 140 mm device width, this MCCB offers an effective solution for three-phase distribution circuits where coordinated switching of the neutral conductor is required. The ABB EPX-XT4N-E2-1604 is intended for integration into compatible ABB Protecta Power distribution assemblies and is identified by ABB order code 1SDX254843R1.

Key Advantages

  • 160 A rated current for substantial commercial and industrial low-voltage distribution circuits.
  • Four-pole (4P) configuration for coordinated switching of three phase conductors and a neutral conductor.
  • 36 kA short-circuit breaking capacity at 415 V AC for appropriately designed installations with significant prospective fault currents.
  • ABB Ekip Dip LSI electronic trip unit provides configurable overload and short-circuit protection.
  • Long-time (L) protection helps protect conductors and connected equipment against sustained overload conditions.
  • Short-time delayed (S) protection supports selective coordination with downstream protective devices.
  • Instantaneous (I) protection provides rapid interruption during high-current short-circuit faults.
  • LSI protection functionality includes long-time, short-time and instantaneous protection characteristics within one electronic trip unit.
  • DIP-switch-adjustable settings allow protection characteristics to be configured for the installation.
  • Four-pole construction supports electrical distribution arrangements requiring neutral switching.
  • 140 mm four-pole width supports efficient installation within compatible distribution assemblies.
  • ABB SACE Tmax XT4N construction combines robust mechanical design with electronic circuit protection.
  • Part of the ABB Protecta Power Devices range for professional electrical distribution applications.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4N-E2-1604 product designation.
  • 160 A rated current for low-voltage circuit protection.
  • Four-pole (4P) construction for three-phase and neutral distribution circuits.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • ABB Ekip Dip LSI electronic trip unit for configurable circuit protection.
  • L function: Adjustable long-time overload protection.
  • S function: Adjustable short-time delayed short-circuit protection.
  • I function: Adjustable instantaneous short-circuit protection.
  • LSI protection arrangement: All three protection functions are included.
  • Electronic current sensing for controlled protective operation.
  • DIP-switch configuration for adjustment of applicable protection thresholds and delays.
  • ABB SACE Tmax XT4N platform with N short-circuit performance classification.
  • XT4N 160 A configuration with a 160 A electronic trip unit.
  • 140 mm four-pole device width for integration into compatible distribution equipment.
  • Fixed breaker construction with front terminals in the corresponding ABB XT4N configuration.
  • Manual switching mechanism with automatic electronic protective tripping.
  • Robust moulded case construction for commercial and industrial electrical environments.
  • Designed for compatible ABB Protecta Power panelboards and distribution assemblies.

Advanced Four-Pole LSI Electronic Protection for Electrical Distribution

The ABB EPX-XT4N-E2-1604 provides dependable circuit protection for low-voltage electrical distribution systems where configurable protective operation and coordinated four-pole switching are required. Its electronic trip unit monitors current conditions and initiates automatic interruption when the configured protective thresholds are exceeded. This helps protect conductors, connected equipment and electrical distribution infrastructure against overloads and short-circuit faults.

The long-time (L) protection function responds to sustained overload conditions. Adjustable long-time protection characteristics allow the circuit breaker to be configured according to conductor current-carrying capacity and connected load requirements. Correctly selected settings help reduce the risk of excessive cable heating while allowing normal electrical equipment operation within the circuit's design limits.

The short-time delayed (S) protection function provides additional flexibility for electrical protection coordination. In an appropriately designed distribution system, a controlled short-time delay can allow a downstream protective device to clear a fault before an upstream breaker operates. This can help minimise unnecessary interruption to unaffected circuits. Actual selectivity must be confirmed using the relevant ABB time-current curves and coordination data.

The instantaneous (I) protection function provides rapid circuit interruption when short-circuit current exceeds the configured threshold. This helps limit the duration of high-current electrical faults. The LSI arrangement includes long-time, short-time delayed and instantaneous protection functions together, offering greater configuration flexibility than an LS/I arrangement in which short-time and instantaneous protection are alternative operating modes.

The four-pole configuration makes the EPX-XT4N-E2-1604 suitable for three-phase distribution circuits where the neutral conductor must be switched alongside the phase conductors. Four-pole switching may be required for specific electrical distribution arrangements, maintenance strategies and installation designs. The suitability of neutral switching and the applicable neutral protection characteristics must be assessed in accordance with the earthing system, installation requirements and ABB technical documentation.

The ABB SACE Tmax XT4N platform provides a robust foundation for electronic circuit protection. The EPX-XT4N-E2-1604 combines a 160 A rated current with a 36 kA ultimate short-circuit breaking capacity at 415 V AC, making it suitable for appropriately designed commercial and industrial distribution circuits. Its 140 mm four-pole width supports integration into compatible electrical distribution assemblies.

As part of the ABB Protecta Power range, this MCCB is intended for installation in compatible panelboards and distribution equipment using the appropriate mounting and connection components. Electrical designers and installers should verify prospective fault current, operating voltage, conductor ratings, protection settings, neutral requirements and protection coordination before commissioning. Correct configuration of the electronic trip unit is essential to achieving the intended protective performance.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible distribution assemblies.
  • Three-phase outgoing circuits requiring four-pole switching.
  • Industrial switchboards and sub-distribution panels.
  • Manufacturing and production facilities.
  • Commercial offices and business premises.
  • Retail buildings and hospitality facilities.
  • Warehouses and logistics centres.
  • Building services and mechanical plant electrical distribution.
  • Distribution circuits requiring adjustable electronic overload protection.
  • Installations requiring coordinated short-time and instantaneous short-circuit protection.
  • Three-phase and neutral distribution circuits requiring appropriately designed four-pole switching.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT4N
ABB order code 1SDX254843R1
Corresponding ABB XT4N circuit breaker reference 1SDA068156R1
Product type Electronic moulded case circuit breaker (MCCB)
Rated current 160 A
Electronic trip unit rated current 160 A
Number of poles 4
Electrical configuration Three-phase and neutral
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Rated operational voltage of corresponding breaker Up to 690 V AC
Protection technology Electronic
Trip unit designation ABB Ekip Dip LSI
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Adjustable delayed short-circuit protection
Instantaneous protection (I) Adjustable instantaneous short-circuit protection
Protection adjustment method DIP switches
Protection functions L, S and I
Frame family XT4
Frame configuration XT4N 160
Frame performance designation N
Device width 140 mm
Corresponding breaker construction Fixed moulded case circuit breaker
Corresponding breaker terminal arrangement Front terminals
Operating mechanism Manual switching with automatic electronic protective tripping
Applicable circuit breaker standard IEC 60947-2
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment
Neutral switching Four-pole configuration; neutral protection settings and characteristics should be confirmed against the applicable ABB technical documentation

Frequently Asked Questions

What is the ABB EPX-XT4N-E2-1604 used for?

The ABB EPX-XT4N-E2-1604 is a four-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT4N-E2-1604?

The circuit breaker has a rated current of 160 A. It incorporates a 160 A ABB Ekip Dip LSI electronic trip unit, providing adjustable overload and short-circuit protection characteristics for appropriately designed electrical distribution circuits.

What is the breaking capacity of this MCCB?

The ABB EPX-XT4N-E2-1604 has a 36 kA rated ultimate short-circuit breaking capacity at 415 V AC. Its suitability must be assessed against the installation's prospective fault current, operating voltage and applicable electrical protection requirements.

What does LSI mean on the ABB Ekip electronic trip unit?

LSI refers to three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). All three functions are included, allowing the protection characteristics to be configured for the electrical installation.

What is the advantage of the four-pole configuration?

The four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design. This can be useful in three-phase and neutral distribution systems, subject to the installation's earthing arrangements, neutral protection requirements and applicable electrical standards.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established electrical engineering with practical low-voltage distribution solutions. The EPX-XT4N-E2-1604 offers a robust 160 A, four-pole XT4N MCCB configuration with adjustable Ekip Dip LSI electronic protection and a 36 kA breaking capacity, supporting dependable and configurable circuit protection in commercial and industrial electrical installations.