1SDX254841R1 ABB EPX-XT4N-E2-0634 63A 4-Pole 36kA LSI Moulded Case Circuit Breaker

1SDX254841R1 ABB EPX-XT4N-E2-0634 63A 4-Pole 36kA LSI Moulded Case Circuit Breaker

ABB EPX-XT4N-E2-0634 is a 63 A four-pole moulded case circuit breaker with 36 kA breaking capacity and an LSI electronic trip unit providing overload, short-time delayed and instantaneous short-circuit protection for low-voltage electrical distribution.

SKU: 1SDX254841R1Alt SKU: EPX-XT4N-E2-0634MPN: 1SDX254841R1
Price
List Price £1,861.62 ex VAT
Your Price (ex VAT)
£1,861.62
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,861.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,861.62

Why Choose the ABB EPX-XT4N-E2-0634 63A 4-Pole MCCB?

The ABB EPX-XT4N-E2-0634 is a 63 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and an LSI electronic protection release, this circuit breaker offers configurable protection for commercial, industrial and infrastructure installations.

Part of the ABB Protecta Power Devices range, the EPX-XT4N-E2-0634 uses ABB SACE Tmax XT4N technology. Its electronic trip unit provides long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions help electrical engineers configure protection settings to suit connected conductors, distribution equipment and downstream protective devices.

With its 63 A rated current, four-pole configuration and 36 kA breaking capacity, the EPX-XT4N-E2-0634 is suitable for three-phase electrical distribution systems requiring electronic circuit protection. Its XT4N construction supports integration into compatible ABB Protecta Power distribution assemblies and other appropriately designed low-voltage switchboards.

Key Advantages

  • 63 A rated current suitable for appropriately designed commercial and industrial distribution circuits.
  • 36 kA short-circuit breaking capacity provides protection against substantial fault currents within the applicable rated conditions.
  • Four-pole configuration supports three-phase electrical distribution arrangements requiring neutral switching.
  • LSI electronic protection combines overload and short-circuit protection functions.
  • Long-time protection (L) helps protect electrical conductors against sustained overload currents.
  • Short-time delayed protection (S) supports coordination with downstream protective devices.
  • Instantaneous protection (I) provides rapid interruption of high short-circuit currents.
  • Configurable electronic protection enables engineers to select appropriate trip characteristics.
  • ABB SACE Tmax XT4N technology provides dependable switching and circuit protection.
  • Protecta Power compatibility makes the device suitable for appropriately configured ABB electrical distribution assemblies.

Key Features

  • ABB EPX-XT4N-E2-0634 moulded case circuit breaker.
  • 63 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA short-circuit breaking capacity.
  • ABB SACE Tmax XT4N circuit breaker platform.
  • LSI electronic trip unit.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Adjustable protection characteristics for electrical distribution applications.
  • Four-pole switching arrangement for suitable three-phase and neutral systems.
  • Manual circuit switching with automatic protective tripping.
  • Designed for low-voltage AC power distribution.
  • Suitable for integration into compatible ABB Protecta Power equipment.
  • Supports protection coordination when correctly configured using ABB technical data.

Configurable LSI Protection for Low-Voltage Electrical Distribution

The ABB EPX-XT4N-E2-0634 provides electronic protection against different overcurrent conditions through its LSI trip unit. Long-time protection responds to sustained overloads, short-time protection introduces a configurable delay for appropriate short-circuit conditions, and instantaneous protection enables rapid fault interruption. These functions help engineers develop protection arrangements suited to the characteristics of the electrical installation.

The combination of a 63 A current rating, four-pole switching and 36 kA breaking capacity makes this MCCB a practical choice for distribution boards, outgoing feeders and industrial electrical panels. Correct protection settings and coordination with upstream and downstream devices remain essential to achieving the required performance.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase distribution systems requiring four-pole circuit protection.
  • Electrical distribution feeders and outgoing circuits.
  • Sub-distribution panels in commercial buildings.
  • Industrial machinery supply circuits.
  • Manufacturing and production facilities.
  • Warehouses and logistics installations.
  • Electrical panel building and switchgear assembly projects.
  • Distribution circuits requiring electronic overload protection.
  • Installations requiring short-time delayed and instantaneous fault protection.
  • Electrical refurbishment and distribution system upgrades.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4N
ABB order code 1SDX254841R1
Product type Moulded case circuit breaker (MCCB)
Rated current 63 A
Number of poles 4
Short-circuit breaking capacity 36 kA
Protection release LSI electronic
Long-time protection (L) Overload protection
Short-time protection (S) Delayed short-circuit protection
Instantaneous protection (I) Short-circuit protection without intentional delay
Protection functions L, S and I
Frame family XT4
Breaking capacity class N
Operating mechanism Manual switching with automatic tripping
Application Low-voltage electrical distribution and circuit protection
Circuit breaker standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-E2-0634 used for?

The ABB EPX-XT4N-E2-0634 is a 63 A four-pole MCCB used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT4N-E2-0634?

The circuit breaker has a rated current of 63 A. Its protection settings must be selected to suit the connected circuit and the manufacturer's instructions.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4N-E2-0634 has a 36 kA short-circuit breaking capacity. The applicable rating must be checked against the installation voltage and prospective fault current.

What does LSI mean on the ABB EPX-XT4N-E2-0634?

LSI refers to long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I).

What is the difference between LSI and LS/I protection?

An LSI release incorporates long-time, short-time delayed and instantaneous protection functions. An LS/I release provides long-time protection with a selectable short-time delayed or instantaneous short-circuit protection function.

Is the ABB EPX-XT4N-E2-0634 a four-pole circuit breaker?

Yes. The EPX-XT4N-E2-0634 is a four-pole (4P) MCCB suitable for appropriately designed three-phase distribution systems requiring four-pole switching.

Does the ABB EPX-XT4N-E2-0634 provide adjustable protection?

Yes. Its LSI electronic trip unit provides configurable protection characteristics. Settings should be determined by the electrical design and verified against ABB's technical documentation.

Can this circuit breaker support protection coordination?

Yes. The short-time delayed and instantaneous protection functions can support coordination with other protective devices. Actual selectivity depends on the selected settings, prospective fault currents and ABB's published coordination data.

What ABB product family does the EPX-XT4N-E2-0634 belong to?

It belongs to the ABB Protecta Power Devices range and uses the ABB SACE Tmax XT4N circuit breaker platform.

Where is the ABB EPX-XT4N-E2-0634 typically installed?

This MCCB is suitable for compatible low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including appropriately configured ABB Protecta Power installations.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used by electrical engineers, panel builders and maintenance professionals for dependable low-voltage circuit protection. The ABB EPX-XT4N-E2-0634 combines a 63 A rated current, four-pole configuration and 36 kA breaking capacity with configurable LSI electronic protection, making it a practical choice for commercial and industrial power distribution.