ABB EPX-XT4N-E2-0404 (1SDX254839R1) is a 40 A four-pole moulded case circuit breaker with a 36 kA breaking capacity at 415 V AC and an electronic LSI trip unit, designed for overload and short-circuit protection in compatible ABB Protecta Power low-voltage distribution systems.
£1,861.62
The ABB EPX-XT4N-E2-0404 (1SDX254839R1) is a high-performance 40 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker is based on the proven ABB SACE Tmax XT4N platform, delivering advanced electronic protection for commercial buildings, industrial installations and electrical distribution assemblies.
Featuring an Ekip electronic LSI trip unit, the EPX-XT4N-E2-0404 provides three essential protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions allow electrical engineers to configure protection characteristics according to the requirements of the installation, helping protect cables, distribution equipment and connected electrical circuits against damaging overcurrent conditions.
With a rated current of 40 A, a four-pole configuration and a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC, the ABB EPX-XT4N-E2-0404 is suitable for three-phase distribution circuits requiring dependable circuit protection and coordinated switching. Its compact XT4N frame and electronic protection technology make it an effective solution for integration into compatible ABB Protecta Power distribution boards.
Moulded case circuit breakers are essential components in modern electrical distribution systems, providing protection against excessive current and short-circuit faults. The ABB EPX-XT4N-E2-0404 combines the mechanical switching capabilities of the SACE Tmax XT4N platform with an electronic LSI trip unit, allowing protection characteristics to be configured according to the requirements of the electrical installation.
The LSI electronic protection system incorporates three complementary functions. Long-time protection (L) responds to sustained overload conditions, helping prevent overheating of electrical conductors and connected equipment. Short-time protection (S) introduces a controlled delay for specified short-circuit conditions, supporting selective coordination between protective devices. Instantaneous protection (I) provides rapid tripping when a sufficiently high fault current is detected.
The circuit breaker has a 40 A rated current and a 36 kA ultimate breaking capacity at 415 V AC. These characteristics make it suitable for appropriately designed distribution circuits where the prospective short-circuit current is within the device's rated capability. The electronic trip unit offers protection flexibility that is particularly useful when coordinating multiple circuit breakers within a distribution system.
Its four-pole configuration supports three-phase and neutral electrical distribution arrangements, allowing all four poles to be operated together. The appropriate neutral protection configuration and protective settings must be selected according to the electrical system design, conductor arrangement and applicable installation requirements.
As part of the ABB Protecta Power Devices range, the EPX-XT4N-E2-0404 is intended for integration into compatible low-voltage distribution assemblies. Correct installation requires the appropriate mounting components, electrical connections and protection settings. Coordination with upstream and downstream protective devices should be assessed to achieve the required fault protection and selectivity.
The ABB EPX-XT4N-E2-0404 is a 40 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is intended for compatible ABB Protecta Power distribution assemblies and commercial or industrial electrical installations.
The circuit breaker has a rated current of 40 A and a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC. It uses the ABB SACE Tmax XT4N circuit breaker platform.
LSI refers to three electronic protection functions: Long-time (L) overload protection, Short-time (S) delayed short-circuit protection and Instantaneous (I) short-circuit protection. These functions allow the circuit breaker to provide configurable protection and support coordination with other protective devices.
Yes. The EPX-XT4N-E2-0404 is a four-pole (4P) MCCB designed for three-phase and neutral electrical distribution systems. Its four-pole arrangement allows the three phase conductors and neutral conductor to be switched together.
The EPX-XT4N-E2-0404 belongs to the ABB Protecta Power Devices range and is designed for integration into compatible ABB Protecta Power low-voltage distribution assemblies. Installation requires the appropriate MCCB mounting arrangement, connection components and accessories specified for the switchboard configuration.
ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, switchboard manufacturers and industrial contractors for dependable low-voltage electrical protection. The ABB EPX-XT4N-E2-0404 40 A four-pole MCCB combines electronic LSI protection, a 36 kA breaking capacity and robust XT4N construction to support reliable circuit protection and coordinated electrical distribution in commercial and industrial installations.