1SDX254837R1 ABB EPX-XT4N-E2-2503 250A 3-Pole 36kA Ekip LSI Moulded Case Circuit Breaker

1SDX254837R1 ABB EPX-XT4N-E2-2503 250A 3-Pole 36kA Ekip LSI Moulded Case Circuit Breaker

ABB EPX-XT4N-E2-2503 is a 250 A three-pole moulded case circuit breaker with 36 kA breaking capacity and an Ekip Dip LSI electronic trip unit providing adjustable overload, short-time delayed and instantaneous short-circuit protection for low-voltage electrical distribution.

SKU: 1SDX254837R1Alt SKU: EPX-XT4N-E2-2503MPN: 1SDX254837R1
Price
List Price £1,737.43 ex VAT
Your Price (ex VAT)
£1,737.43
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,737.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,737.43

Why Choose the ABB EPX-XT4N-E2-2503 250A 3-Pole MCCB?

The ABB EPX-XT4N-E2-2503 is a high-performance 250 A three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short circuits. Featuring a 36 kA breaking capacity and an Ekip Dip LSI electronic trip unit, this circuit breaker provides adjustable protection for commercial, industrial and infrastructure electrical installations.

Part of the ABB Protecta Power Devices range, the EPX-XT4N-E2-2503 incorporates proven ABB SACE Tmax XT4N 250 circuit breaker technology. Its electronic trip unit combines long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I), allowing engineers to configure protection characteristics according to circuit requirements.

With its 250 A rated current, three-pole configuration and 36 kA short-circuit breaking capacity, the EPX-XT4N-E2-2503 is suitable for three-phase electrical distribution systems requiring dependable electronic protection. Its fixed-mounted design, front terminals and compact XT4 frame support integration into compatible ABB Protecta Power distribution assemblies and industrial switchboards.

Key Advantages

  • 250 A rated current suitable for high-capacity commercial and industrial distribution circuits.
  • 36 kA breaking capacity provides protection against substantial prospective short-circuit currents within the applicable rated conditions.
  • Three-pole configuration supports three-phase electrical distribution applications.
  • Ekip Dip LSI electronic trip unit combines overload and short-circuit protection functions.
  • Adjustable long-time protection (L) helps protect conductors and connected equipment against sustained overload currents.
  • Short-time delayed protection (S) supports coordination with downstream protective devices.
  • Instantaneous protection (I) provides rapid interruption of high short-circuit currents.
  • LSI functionality offers long-time, short-time and instantaneous protection within the same electronic release.
  • ABB SACE Tmax XT4N construction provides dependable circuit protection and switching performance.
  • Fixed-mounted design with front terminals supports straightforward integration into suitable electrical assemblies.
  • Suitable for compatible ABB Protecta Power distribution boards and industrial switchgear systems.

Key Features

  • ABB EPX-XT4N-E2-2503 moulded case circuit breaker.
  • 250 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA short-circuit breaking capacity.
  • ABB SACE Tmax XT4N 250 series.
  • Ekip Dip LSI electronic protection release.
  • Long-time overload protection (L) with adjustable settings.
  • Short-time delayed short-circuit protection (S) for configurable fault response.
  • Instantaneous short-circuit protection (I) for rapid fault interruption.
  • Electronic protection technology designed for low-voltage AC distribution systems.
  • Fixed installation with front connection terminals.
  • Manual operating mechanism for circuit switching.
  • Rated operational voltage up to 690 V AC for the corresponding base circuit breaker.
  • Designed for integration into appropriately selected electrical distribution equipment.
  • Compatible with suitable ABB Tmax XT accessories, subject to manufacturer compatibility requirements.

Advanced LSI Electronic Protection for Three-Phase Power Distribution

The ABB EPX-XT4N-E2-2503 incorporates an Ekip Dip LSI electronic trip unit designed to respond to different electrical overcurrent conditions. The long-time protection function helps prevent damage caused by sustained overloads, while short-time delayed protection allows a controlled response to short-circuit conditions. Instantaneous protection provides rapid tripping when severe fault currents are detected. Together, these functions offer flexibility when designing and coordinating electrical protection systems.

Built on the ABB SACE Tmax XT4N 250 platform, this MCCB combines a 250 A current rating, three-pole switching arrangement and 36 kA breaking capacity in a compact protective device. Its fixed-mounted construction and front terminals support installation within suitable distribution assemblies. For electrical contractors and panel builders, the EPX-XT4N-E2-2503 provides a practical solution for protecting three-phase feeders, distribution circuits and industrial power systems.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution systems requiring three-pole protection.
  • 250 A electrical distribution feeders and outgoing circuits.
  • Main and secondary distribution panels in commercial buildings.
  • Industrial machinery and equipment supply circuits.
  • Manufacturing facilities and production environments.
  • Warehouses, logistics centres and industrial infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Distribution networks requiring configurable electronic overload protection.
  • Installations requiring short-time delayed and instantaneous short-circuit protection.
  • Power distribution systems where coordination with downstream protective devices is required.
  • Electrical installation upgrades, maintenance and refurbishment projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4N
Frame designation XT4N 250
ABB order code 1SDX254837R1
ABB base circuit breaker reference 1SDA068136R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 250 A
Number of poles 3
Short-circuit breaking capacity 36 kA
Trip unit Ekip Dip LSI
Release type Electronic
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Delayed short-circuit protection
Instantaneous protection (I) Short-circuit protection without intentional delay
Protection functions L, S and I
Frame size XT4
Frame current rating 250 A
Breaking capacity class N
Rated operational voltage Up to 690 V AC
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Operating mechanism Manual lever
Applicable standard IEC 60947-2
Application Low-voltage three-phase electrical distribution and circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-E2-2503 used for?

The ABB EPX-XT4N-E2-2503 is a 250 A three-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT4N-E2-2503?

The circuit breaker has a rated current of 250 A and uses an ABB SACE Tmax XT4N 250 configuration with a 250 A Ekip Dip LSI electronic protection release.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4N-E2-2503 has a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the installation.

What does LSI mean on the ABB EPX-XT4N-E2-2503?

LSI refers to three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions help protect electrical circuits against different types of overcurrent conditions.

What is the difference between LSI and LS/I protection?

An LSI trip unit includes long-time, short-time delayed and instantaneous protection functions. An LS/I trip unit provides long-time protection together with a choice between short-time delayed or instantaneous protection. LSI offers both short-circuit protection functions within the same electronic release.

Does the ABB EPX-XT4N-E2-2503 have adjustable protection settings?

Yes. The Ekip Dip LSI electronic trip unit provides adjustable overload and short-circuit protection characteristics. Settings must be selected according to the circuit design, conductor ratings and ABB's technical instructions.

Is the ABB EPX-XT4N-E2-2503 a three-pole circuit breaker?

Yes. The EPX-XT4N-E2-2503 is a three-pole (3P) MCCB designed for three-phase electrical distribution systems requiring three-pole switching and circuit protection.

What ABB circuit breaker series does this model belong to?

The EPX-XT4N-E2-2503 belongs to the ABB Protecta Power Devices range and uses ABB SACE Tmax XT4N 250 technology. Its corresponding ABB base circuit breaker reference is 1SDA068136R1.

Can the ABB EPX-XT4N-E2-2503 support protection coordination?

Yes. Its Ekip Dip LSI electronic release includes short-time delayed and instantaneous protection functions that can support coordination with downstream circuit breakers. Actual selectivity depends on the selected settings, fault levels and ABB's published coordination data.

What is the difference between a 250A XT4N and a 250A XT5N MCCB?

Both XT4N and XT5N circuit breakers are available in 250 A configurations, but they use different frame sizes and mechanical arrangements. The EPX-XT4N-E2-2503 uses the XT4N 250 frame. Installation dimensions, connections, accessories and panel compatibility must be checked before substituting one frame for another.

Where is the ABB EPX-XT4N-E2-2503 typically installed?

This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems. Its fixed-mounted construction and front terminals support integration into suitable electrical enclosures.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT4N-E2-2503 combines a 250 A rated current, three-pole configuration and 36 kA breaking capacity with configurable Ekip Dip LSI electronic protection, making it a practical choice for reliable three-phase low-voltage electrical distribution.