ABB EPX-XT4N-E2-2503 is a 250 A three-pole moulded case circuit breaker with 36 kA breaking capacity and an Ekip Dip LSI electronic trip unit providing adjustable overload, short-time delayed and instantaneous short-circuit protection for low-voltage electrical distribution.
£1,737.43
The ABB EPX-XT4N-E2-2503 is a high-performance 250 A three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short circuits. Featuring a 36 kA breaking capacity and an Ekip Dip LSI electronic trip unit, this circuit breaker provides adjustable protection for commercial, industrial and infrastructure electrical installations.
Part of the ABB Protecta Power Devices range, the EPX-XT4N-E2-2503 incorporates proven ABB SACE Tmax XT4N 250 circuit breaker technology. Its electronic trip unit combines long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I), allowing engineers to configure protection characteristics according to circuit requirements.
With its 250 A rated current, three-pole configuration and 36 kA short-circuit breaking capacity, the EPX-XT4N-E2-2503 is suitable for three-phase electrical distribution systems requiring dependable electronic protection. Its fixed-mounted design, front terminals and compact XT4 frame support integration into compatible ABB Protecta Power distribution assemblies and industrial switchboards.
The ABB EPX-XT4N-E2-2503 incorporates an Ekip Dip LSI electronic trip unit designed to respond to different electrical overcurrent conditions. The long-time protection function helps prevent damage caused by sustained overloads, while short-time delayed protection allows a controlled response to short-circuit conditions. Instantaneous protection provides rapid tripping when severe fault currents are detected. Together, these functions offer flexibility when designing and coordinating electrical protection systems.
Built on the ABB SACE Tmax XT4N 250 platform, this MCCB combines a 250 A current rating, three-pole switching arrangement and 36 kA breaking capacity in a compact protective device. Its fixed-mounted construction and front terminals support installation within suitable distribution assemblies. For electrical contractors and panel builders, the EPX-XT4N-E2-2503 provides a practical solution for protecting three-phase feeders, distribution circuits and industrial power systems.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker family | SACE Tmax XT |
| Series | XT4N |
| Frame designation | XT4N 250 |
| ABB order code | 1SDX254837R1 |
| ABB base circuit breaker reference | 1SDA068136R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 250 A |
| Number of poles | 3 |
| Short-circuit breaking capacity | 36 kA |
| Trip unit | Ekip Dip LSI |
| Release type | Electronic |
| Long-time protection (L) | Adjustable overload protection |
| Short-time protection (S) | Delayed short-circuit protection |
| Instantaneous protection (I) | Short-circuit protection without intentional delay |
| Protection functions | L, S and I |
| Frame size | XT4 |
| Frame current rating | 250 A |
| Breaking capacity class | N |
| Rated operational voltage | Up to 690 V AC |
| Mounting arrangement | Fixed installation |
| Terminal arrangement | Front terminals |
| Operating mechanism | Manual lever |
| Applicable standard | IEC 60947-2 |
| Application | Low-voltage three-phase electrical distribution and circuit protection |
The ABB EPX-XT4N-E2-2503 is a 250 A three-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.
The circuit breaker has a rated current of 250 A and uses an ABB SACE Tmax XT4N 250 configuration with a 250 A Ekip Dip LSI electronic protection release.
The EPX-XT4N-E2-2503 has a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the installation.
LSI refers to three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions help protect electrical circuits against different types of overcurrent conditions.
An LSI trip unit includes long-time, short-time delayed and instantaneous protection functions. An LS/I trip unit provides long-time protection together with a choice between short-time delayed or instantaneous protection. LSI offers both short-circuit protection functions within the same electronic release.
Yes. The Ekip Dip LSI electronic trip unit provides adjustable overload and short-circuit protection characteristics. Settings must be selected according to the circuit design, conductor ratings and ABB's technical instructions.
Yes. The EPX-XT4N-E2-2503 is a three-pole (3P) MCCB designed for three-phase electrical distribution systems requiring three-pole switching and circuit protection.
The EPX-XT4N-E2-2503 belongs to the ABB Protecta Power Devices range and uses ABB SACE Tmax XT4N 250 technology. Its corresponding ABB base circuit breaker reference is 1SDA068136R1.
Yes. Its Ekip Dip LSI electronic release includes short-time delayed and instantaneous protection functions that can support coordination with downstream circuit breakers. Actual selectivity depends on the selected settings, fault levels and ABB's published coordination data.
Both XT4N and XT5N circuit breakers are available in 250 A configurations, but they use different frame sizes and mechanical arrangements. The EPX-XT4N-E2-2503 uses the XT4N 250 frame. Installation dimensions, connections, accessories and panel compatibility must be checked before substituting one frame for another.
This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems. Its fixed-mounted construction and front terminals support integration into suitable electrical enclosures.
ABB SACE Tmax XT moulded case circuit breakers are widely used by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT4N-E2-2503 combines a 250 A rated current, three-pole configuration and 36 kA breaking capacity with configurable Ekip Dip LSI electronic protection, making it a practical choice for reliable three-phase low-voltage electrical distribution.