ABB EPX-XT4N-E2-1003 is a 100 A three-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring an Ekip LSI trip unit with long-time, short-time and instantaneous protection for low-voltage electrical distribution systems.

SKU: 1SDX254835R1Alt SKU: EPX-XT4N-E2-1003MPN: 1SDX254835R1
Price
List Price £1,403.31 ex VAT
Your Price (ex VAT)
£1,403.31
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,403.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,403.31

Why Choose the ABB EPX-XT4N-E2-1003 100A 3-Pole MCCB?

The ABB EPX-XT4N-E2-1003 is a high-performance 100 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT4N 160 A frame platform, combining robust construction with electronic protection technology for commercial buildings, industrial facilities and electrical distribution assemblies.

Equipped with an ABB Ekip LSI electronic trip unit, the EPX-XT4N-E2-1003 provides three important protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These electronic protection characteristics enable engineers to configure suitable trip settings for electrical circuits and support coordination with other protective devices.

With a rated current of 100 A, a three-pole configuration and a specified 36 kA short-circuit breaking capacity, this MCCB is suitable for protecting three-phase outgoing feeders and distribution circuits. Its compact 110 mm-wide XT4 frame facilitates integration into compatible ABB Protecta Power distribution boards, making it a practical solution for electrical contractors, panel builders and maintenance engineers requiring reliable electronic circuit protection.

Key Advantages

  • 100 A rated current: Suitable for protecting appropriately designed low-voltage three-phase electrical circuits.
  • Three-pole construction: Provides coordinated switching and protection of three phase conductors.
  • 36 kA breaking capacity: Offers substantial short-circuit interruption capability under the applicable rated conditions.
  • Advanced Ekip LSI electronic protection: Incorporates long-time, short-time and instantaneous protection characteristics.
  • Adjustable overload protection: Supports coordination of circuit protection settings with cable and installation requirements.
  • Short-time delayed protection: Helps achieve selective coordination with downstream protective devices where the system design permits.
  • Instantaneous short-circuit protection: Provides rapid interruption when high-current faults exceed the configured threshold.
  • Electronic trip technology: Offers flexible protection settings compared with conventional thermal-magnetic MCCBs.
  • ABB Tmax XT4N platform: Uses established ABB circuit breaker technology for dependable electrical protection.
  • Compact installation: The 110 mm nominal width helps optimise space within distribution assemblies.
  • Protecta Power integration: Designed for use with appropriately selected ABB Protecta Power distribution boards.
  • Robust moulded case construction: Suitable for commercial and industrial electrical distribution environments.

Key Features

  • Manufacturer: ABB.
  • Product family: ABB Protecta Power Devices.
  • Circuit breaker platform: ABB SACE Tmax XT4N.
  • Rated current: 100 A.
  • Number of poles: 3.
  • Specified short-circuit breaking capacity: 36 kA.
  • Electronic trip unit: ABB Ekip LSI.
  • L function: Long-time overload protection against sustained excessive current.
  • S function: Short-time delayed short-circuit protection supporting selective coordination.
  • I function: Instantaneous short-circuit protection for rapid fault interruption.
  • Protection configuration: L, S and I protection characteristics incorporated within the electronic trip system.
  • Frame designation: XT4N 160.
  • Frame current class: 160 A.
  • Nominal device width: 110 mm.
  • Operating mechanism: Manual front-operated switching mechanism.
  • Trip indication: Circuit breaker operating mechanism indicates a tripped condition.
  • Installation compatibility: Suitable for appropriately selected ABB Tmax XT4 mounting and connection arrangements.
  • Product family standard: IEC/EN 60947-2.

Reliable Ekip LSI Electronic Protection for Electrical Distribution

The ABB EPX-XT4N-E2-1003 uses electronic current monitoring to protect electrical circuits against abnormal operating conditions. Its long-time (L) protection responds to sustained overloads that could otherwise lead to excessive cable temperatures or damage connected equipment. The short-time (S) protection introduces a controlled delay for selected short-circuit conditions, supporting coordination with downstream protective devices. The instantaneous (I) protection provides rapid circuit interruption when high-current faults exceed the configured protection threshold.

A significant advantage of the ABB Ekip LSI trip unit is that all three protection characteristics are available within the same electronic protection system. Unlike LS/I configurations, where short-time and instantaneous protection are selected as alternatives, LSI protection offers greater flexibility when configuring circuit protection. This can help improve selectivity, minimise unnecessary upstream interruptions and support more effective fault management in appropriately engineered electrical distribution networks.

The ABB SACE Tmax XT4N platform combines these electronic protection capabilities with robust moulded case construction. Its three-pole arrangement is suitable for protecting three-phase electrical circuits, while its compact frame facilitates integration into compatible ABB Protecta Power distribution assemblies. Correct selection of trip settings, cable ratings, operating voltage, prospective short-circuit current and protective device coordination remains essential for safe and reliable operation.

Typical Applications

  • ABB Protecta Power distribution boards: Electronic protection for compatible outgoing electrical circuits.
  • Commercial electrical distribution: Circuit protection in offices, retail premises and commercial buildings.
  • Industrial switchboards: Three-phase feeder protection in industrial electrical installations.
  • Main and sub-distribution boards: Protection of outgoing circuits requiring adjustable electronic trip characteristics.
  • Electrical control panels: Protection of suitable three-phase electrical supply circuits.
  • Building services: Electrical distribution for heating, ventilation, air conditioning and mechanical plant.
  • Machinery supply circuits: Overload and short-circuit protection where the selected trip characteristics suit the connected equipment.
  • Commercial infrastructure: Power distribution in warehouses, educational facilities and public buildings.
  • Coordinated electrical networks: Installations requiring long-time, short-time and instantaneous protection functions.
  • Panel building projects: Distribution assemblies designed around the ABB SACE Tmax XT4 circuit breaker platform.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT4
Product model EPX-XT4N-E2-1003
ABB order code 1SDX254835R1
Corresponding ABB circuit breaker reference 1SDA068134R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT4N 160
Frame current class 160 A
Rated current (In) 100 A
Number of poles 3
Specified short-circuit breaking capacity 36 kA
Trip unit technology Electronic
Trip unit ABB Ekip LSI
Long-time protection (L) Overload protection
Short-time protection (S) Delayed short-circuit protection
Instantaneous protection (I) Instantaneous short-circuit protection
Protection characteristics LSI
Rated insulation voltage (Ui), XT4 series 1000 V
Rated impulse withstand voltage (Uimp), XT4 series 8 kV
Electrical system Low-voltage AC distribution
Phase configuration Three-phase
Nominal device width 110 mm
Operating mechanism Manual toggle operation
Primary function Overload and short-circuit protection
Additional function Circuit switching and isolation in accordance with manufacturer installation requirements
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-E2-1003 used for?

The ABB EPX-XT4N-E2-1003 is a 100 A three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible ABB Protecta Power distribution boards and commercial or industrial switchgear assemblies.

What is the rated current of the EPX-XT4N-E2-1003?

The EPX-XT4N-E2-1003 has a 100 A rated current. It uses the ABB SACE Tmax XT4N 160 A frame platform, but the rated current of this individual circuit breaker is 100 A rather than the maximum current class of the frame.

What is the breaking capacity of this ABB MCCB?

The circuit breaker has a specified 36 kA short-circuit breaking capacity. The applicable operating voltage, manufacturer short-circuit rating conditions and installation prospective fault current should be checked when selecting the device.

What does Ekip LSI electronic protection mean?

Ekip LSI is an electronic trip system incorporating long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). These functions provide flexible protection characteristics for low-voltage electrical distribution applications.

What is the difference between Ekip LSI and Ekip LS/I?

Ekip LSI incorporates long-time, short-time and instantaneous protection characteristics within the same electronic trip system. Ekip LS/I provides long-time protection together with a choice between short-time and instantaneous protection. LSI therefore offers additional flexibility when coordinating protective devices.

Is the EPX-XT4N-E2-1003 suitable for three-phase electrical systems?

Yes. The EPX-XT4N-E2-1003 has a three-pole configuration designed for switching and protecting three phase conductors. It is suitable for appropriately designed three-phase low-voltage electrical distribution circuits where neutral switching is not required through the breaker.

Can the EPX-XT4N-E2-1003 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT4N-E2-1003 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible distribution assemblies. The appropriate XT4 mounting arrangement, electrical connections, enclosure compatibility and electronic protection settings should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining adjustable electronic trip functionality, robust construction and dependable overload and short-circuit protection for modern low-voltage power systems.