1SDX254833R1 ABB EPX-XT4N-E2-0403 40A 3-Pole 36kA Ekip Dip LSI MCCB

1SDX254833R1 ABB EPX-XT4N-E2-0403 40A 3-Pole 36kA Ekip Dip LSI MCCB

ABB EPX-XT4N-E2-0403 is a 40 A three-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 36 kA breaking capacity at 415 V AC and an Ekip Dip LSI electronic trip unit providing long-time, short-time and instantaneous protection for low-voltage electrical distribution systems.

SKU: 1SDX254833R1Alt SKU: EPX-XT4N-E2-0403MPN: 1SDX254833R1
Price
List Price £1,055.43 ex VAT
Your Price (ex VAT)
£1,055.43
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,055.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,055.43

Why Choose the ABB EPX-XT4N-E2-0403 40A 3-Pole MCCB?

The ABB EPX-XT4N-E2-0403 is a high-performance 40 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT4N160 platform, delivering dependable electrical protection for commercial buildings, industrial facilities and electrical infrastructure.

Equipped with an ABB Ekip Dip LSI electronic trip unit, the EPX-XT4N-E2-0403 provides three essential protection functions: long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I). Its electronic trip technology enables configurable protection characteristics, supporting coordination between protective devices and helping safeguard distribution cables, switchgear and connected equipment.

With a 40 A rated current, three-pole construction and 36 kA breaking capacity at 415 V AC, this MCCB is suitable for three-phase electrical distribution systems. Its compact XT4N160 frame, fixed-mounted construction and front terminal arrangement support integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • 40 A rated current for commercial and industrial electrical distribution circuits.
  • Three-pole configuration suitable for three-phase electrical systems.
  • 36 kA breaking capacity at 415 V AC provides dependable short-circuit fault interruption.
  • ABB Ekip Dip LSI electronic trip unit delivers comprehensive overload and short-circuit protection.
  • Long-time overload protection (L) helps protect cables and connected electrical equipment against sustained excessive current.
  • Short-time protection (S) supports time-delayed fault clearance and protection coordination.
  • Instantaneous protection (I) provides rapid interruption of high-current short-circuit faults.
  • Electronic trip settings offer flexible protection adjustment compared with conventional fixed thermal-magnetic arrangements.
  • Compact ABB Tmax XT4N160 frame supports efficient use of distribution board space.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT4N160 moulded case circuit breaker platform.
  • 40 A rated electronic trip unit current.
  • Three-pole (3P) construction.
  • 36 kA rated short-circuit breaking capacity at 415 V AC.
  • Ekip Dip LSI electronic protection unit.
  • Long-time (L) protection against sustained overload conditions.
  • Short-time (S) protection against short-circuit faults with adjustable delay characteristics.
  • Instantaneous (I) protection for rapid interruption of severe short-circuit faults.
  • Adjustable electronic protection settings for circuit coordination.
  • XT4N160 frame with a maximum frame rating of 160 A.
  • 110 mm three-pole frame width for compact electrical distribution assemblies.
  • Fixed-mounted construction with front terminal connections.
  • Manual toggle operating mechanism with trip indication and reset functionality.
  • Suitable for low-voltage three-phase distribution systems.
  • Compatible with appropriately selected ABB Tmax XT4 installation accessories.

Advanced LSI Electronic Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4N-E2-0403 protect electrical installations by automatically interrupting current when overload or short-circuit faults occur. Its Ekip Dip LSI electronic trip unit provides long-time protection against sustained overloads, short-time protection for controlled fault clearance and instantaneous protection for rapid interruption of severe short circuits. These functions help protect distribution cables, electrical equipment and connected circuits while supporting effective coordination with other protective devices.

The ABB SACE Tmax XT4 circuit breaker family is designed for dependable performance in modern low-voltage electrical distribution systems. Its compact construction, electronic protection technology and compatibility with suitable ABB accessories support integration into commercial and industrial electrical infrastructure. The EPX-XT4N-E2-0403 is particularly suited to installations requiring 40 A three-pole circuit protection and a 36 kA fault-breaking rating at 415 V AC, subject to verification of operating voltage, prospective fault current, cable characteristics and protection coordination requirements.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Low-voltage main and sub-distribution switchboards.
  • Industrial machinery supply circuits and electrical feeders.
  • Building services and commercial electrical infrastructure.
  • Manufacturing facilities, warehouses and industrial premises.
  • Electrical distribution circuits requiring electronic overload and short-circuit protection.
  • Industrial control panels and power distribution installations.
  • Electrical installations requiring coordinated LSI protection.

Technical Specifications

Product group Protecta Power Devices
Product series SACE Tmax XT
Frame designation XT4N160
ABB order code 1SDX254833R1
Corresponding ABB circuit breaker reference 1SDA068132R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 40 A
Number of poles 3
Rated short-circuit breaking capacity 36 kA at 415 V AC
Trip unit Ekip Dip LSI
Trip unit technology Electronic
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Short-circuit protection with time-delay functionality
Instantaneous protection (I) Short-circuit protection without intentional delay
Protection functions L, S and I
Frame family XT4N160
Maximum frame rating 160 A
Rated operational voltage Up to 690 V AC
Three-pole frame width 110 mm
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual toggle operation
Application Low-voltage three-phase electrical distribution
Installation Compatible electrical distribution boards and switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-E2-0403 used for?

The ABB EPX-XT4N-E2-0403 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial three-phase electrical systems.

What is the rated current of the EPX-XT4N-E2-0403?

The circuit breaker has a 40 A rated current and uses the ABB Tmax XT4N160 frame, which has a maximum frame rating of 160 A. Its Ekip Dip LSI electronic trip unit provides configurable protection characteristics for appropriately designed electrical distribution circuits.

What is the breaking capacity of this MCCB?

The EPX-XT4N-E2-0403 has a 36 kA short-circuit breaking capacity at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current before selection.

What protection does the Ekip Dip LSI electronic trip unit provide?

The ABB Ekip Dip LSI electronic trip unit provides three protection functions: long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I). These functions support configurable fault protection and coordination between protective devices in electrical distribution systems.

Where is the ABB EPX-XT4N-E2-0403 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where three-pole electronic circuit protection is required. Its fixed-mounted construction, front terminal connections and 110 mm three-pole width support integration into suitable electrical distribution panels.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT4N-E2-0403 combines a 40 A rating, three-pole construction, 36 kA breaking capacity and advanced Ekip Dip LSI electronic protection in a compact circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.