1SDX254831R1 ABB EPX-XT2N-E2-1004 100A 4P 36kA MCCB Ekip LSI

1SDX254831R1 ABB EPX-XT2N-E2-1004 100A 4P 36kA MCCB Ekip LSI

ABB EPX-XT2N-E2-1004 is a 100 A four-pole SACE Tmax XT2N160 moulded case circuit breaker with 36 kA breaking capacity and Ekip LSI electronic overload, short-time and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254831R1Alt SKU: EPX-XT2N-E2-1004MPN: 1SDX254831R1
Price
List Price £1,675.04 ex VAT
Your Price (ex VAT)
£1,675.04
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,675.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,675.04

Why Choose the ABB EPX-XT2N-E2-1004 Protecta Power Circuit Breaker?

The ABB EPX-XT2N-E2-1004 is a high-performance 100 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB SACE Tmax XT2N160 platform with an Ekip LSI electronic trip unit, offering advanced protection for compatible electrical distribution assemblies.

Featuring a 36 kA short-circuit breaking capacity, the EPX-XT2N-E2-1004 is designed to interrupt electrical faults while helping protect conductors, switchgear and connected equipment. Its electronic trip unit incorporates long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I), providing flexibility for protective device coordination throughout low-voltage electrical installations.

With a 100 A rated current, four-pole configuration and compact 120 mm nominal width, this MCCB is suitable for three-phase distribution systems requiring four-pole switching. Its robust ABB Tmax XT2N construction and configurable electronic protection make it a practical solution for electrical contractors, panel builders and maintenance engineers working with ABB Protecta Power distribution boards.

Key Advantages

  • 100 A rated current provides protection for appropriately designed low-voltage electrical distribution circuits.
  • Four-pole (4P) configuration supports simultaneous switching of three phase conductors and a neutral conductor where required.
  • 36 kA short-circuit breaking capacity provides protection against significant prospective electrical fault currents.
  • Ekip LSI electronic trip unit incorporates long-time, short-time delayed and instantaneous protection functions.
  • Configurable electronic protection characteristics support circuit protection coordination and selectivity.
  • Long-time overload protection (L) helps prevent conductor overheating caused by sustained excessive current.
  • Short-time delayed protection (S) can assist coordination with downstream protective devices.
  • Instantaneous protection (I) enables rapid interruption of high short-circuit currents.
  • ABB SACE Tmax XT2N160 platform combines compact construction with advanced electronic protection.
  • 120 mm nominal width supports efficient integration into compatible distribution boards and switchboards.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT2N-E2-1004 model designation.
  • ABB SACE Tmax XT2N moulded case circuit breaker platform.
  • 100 A rated current.
  • XT2N160 frame with a maximum frame rating of 160 A.
  • Four-pole (4P) circuit breaker construction.
  • 36 kA short-circuit breaking capacity.
  • Ekip LSI electronic trip unit.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection.
  • I protection: Instantaneous short-circuit protection.
  • Electronic trip technology with configurable protection characteristics.
  • Separate L, S and I protection functions for improved coordination flexibility.
  • Four-pole switching capability for compatible three-phase and neutral distribution systems.
  • Manual operating mechanism for circuit switching and resetting.
  • 120 mm nominal width for the four-pole XT2 electronic-trip configuration.
  • Suitable for low-voltage AC electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.

Advanced Ekip LSI Electronic Protection for Four-Pole Distribution

The ABB EPX-XT2N-E2-1004 incorporates an Ekip LSI electronic trip unit designed to protect electrical installations against sustained overloads and short-circuit faults. Electronic protection technology uses current sensing and electronic processing to deliver defined protective characteristics, helping electrical designers achieve suitable protection coordination throughout low-voltage distribution systems.

The L (long-time) protection function responds to sustained excessive current, helping prevent overheating of electrical conductors and connected equipment. The S (short-time) protection function provides delayed short-circuit protection, which can support selectivity with downstream protective devices. The I (instantaneous) protection function responds rapidly to high short-circuit currents, helping minimise the duration of severe electrical faults.

Unlike an LS/I trip unit, which offers a choice between short-time and instantaneous protection, the Ekip LSI arrangement incorporates all three L, S and I protection functions. This provides additional flexibility when coordinating protection across multiple levels of an electrical distribution network, subject to the available settings and the overall system design.

The four-pole construction supports installations where three phase conductors and a neutral conductor must be switched together. This arrangement is particularly useful in compatible three-phase and neutral distribution systems. The neutral pole's protection characteristics and suitability must be verified for the specific circuit breaker configuration and installation requirements.

The ABB SACE Tmax XT2N160 platform combines compact moulded case construction with electronic protection. Its 120 mm nominal four-pole width provides a space-efficient footprint for compatible distribution boards and switchboards. When installing the EPX-XT2N-E2-1004, electrical designers should verify conductor ratings, prospective fault current, neutral arrangements, electronic trip settings and protective device coordination before commissioning.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical switchboards and distribution panels.
  • 100 A four-pole outgoing feeder protection.
  • Three-phase and neutral distribution circuits.
  • Building services and mechanical plant distribution.
  • Commercial premises and office building electrical infrastructure.
  • Manufacturing and industrial facility electrical installations.
  • Commercial switchboards and sub-distribution assemblies.
  • Electrical panel building and switchboard manufacturing.
  • Distribution circuits requiring electronic LSI overload and short-circuit protection.
  • Electrical installations requiring coordinated upstream and downstream protective devices.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series SACE Tmax XT
Circuit breaker frame XT2
Performance level XT2N
Frame configuration XT2N160
ABB order code 1SDX254831R1
Product type Moulded case circuit breaker (MCCB)
Rated current 100 A
Maximum frame rating 160 A
Number of poles 4P (four pole)
Short-circuit breaking capacity 36 kA
Trip unit Ekip LSI
Trip technology Electronic
Overload protection L – long-time protection
Short-time protection S – short-time delayed short-circuit protection
Instantaneous protection I – instantaneous short-circuit protection
Protection configuration LSI – long-time, short-time and instantaneous functions
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Nominal width 120 mm
Applicable standard IEC 60947-2
Installation type Electrical distribution board / switchboard mounting
Compatible system ABB Protecta Power
Product category Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT2N-E2-1004 used for?

The ABB EPX-XT2N-E2-1004 is a 100 A four-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using an Ekip LSI electronic trip unit.

What is the rated current of the EPX-XT2N-E2-1004?

The EPX-XT2N-E2-1004 has a 100 A rated current and uses the ABB SACE Tmax XT2N160 platform, which has a maximum frame rating of 160 A. The frame rating does not change the specified 100 A rating of this device.

What is the breaking capacity of this circuit breaker?

The EPX-XT2N-E2-1004 is specified with a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.

What does LSI mean on the ABB EPX-XT2N-E2-1004?

LSI identifies an electronic protection arrangement incorporating L (long-time overload protection), S (short-time delayed short-circuit protection) and I (instantaneous short-circuit protection). These functions provide configurable protection characteristics for low-voltage electrical distribution systems.

What is the difference between Ekip LSI and Ekip LS/I?

Ekip LSI incorporates long-time, short-time delayed and instantaneous protection functions together. Ekip LS/I provides long-time overload protection with a choice between short-time delayed or instantaneous short-circuit protection. The LSI arrangement offers additional flexibility for protective device coordination.

What is the difference between the EPX-XT2N-E2-0634 and EPX-XT2N-E2-1004?

Both circuit breakers use the ABB SACE Tmax XT2N160 four-pole platform and feature 36 kA breaking capacity with Ekip LSI electronic protection. The EPX-XT2N-E2-0634 has a rated current of 63 A, while the EPX-XT2N-E2-1004 has a rated current of 100 A.

What is the nominal width of the EPX-XT2N-E2-1004?

The ABB EPX-XT2N-E2-1004 uses the four-pole XT2 electronic-trip frame arrangement with a nominal width of 120 mm. Additional installation clearance may be required depending on the mounting arrangement, terminals and accessories.

Can the EPX-XT2N-E2-1004 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2N-E2-1004 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT2 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.

Trusted ABB Electronic Circuit Protection for Electrical Distribution

ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT2N-E2-1004 combines a 100 A four-pole XT2N160 circuit breaker with 36 kA breaking capacity and Ekip LSI electronic protection, delivering a compact and configurable solution for compatible ABB Protecta Power distribution assemblies.