ABB EPX-XT2N-E2-0634 is a 63 A four-pole SACE Tmax XT2N160 moulded case circuit breaker with 36 kA breaking capacity and Ekip LSI electronic overload, short-time and instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£1,515.58
The ABB EPX-XT2N-E2-0634 is a high-performance 63 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker uses the ABB SACE Tmax XT2N160 platform with an Ekip LSI electronic trip unit, delivering configurable protection for electrical distribution assemblies.
Featuring a 36 kA short-circuit breaking capacity, the EPX-XT2N-E2-0634 helps protect electrical conductors, switchgear and connected equipment against potentially damaging fault currents. Its electronic trip unit incorporates long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I), providing greater flexibility when coordinating protective devices throughout an electrical installation.
With a 63 A rated current, four-pole configuration and compact 120 mm nominal width, this MCCB is suitable for three-phase distribution systems requiring four-pole switching. Its established ABB Tmax XT2N construction and advanced electronic protection make it a practical choice for electrical contractors, panel builders and maintenance engineers working with ABB Protecta Power distribution boards.
The ABB EPX-XT2N-E2-0634 incorporates an Ekip LSI electronic trip unit designed to protect electrical installations against overloads and short-circuit faults. Electronic protection technology uses current sensing and electronic processing to deliver defined protective characteristics, helping electrical designers achieve suitable protection coordination within low-voltage distribution systems.
The L (long-time) protection function responds to sustained excessive current, helping prevent overheating of electrical conductors and connected equipment. The S (short-time) protection function provides delayed short-circuit protection, which can support selectivity with downstream protective devices. The I (instantaneous) protection function responds rapidly to high short-circuit currents, helping minimise the duration of severe electrical faults.
Unlike an LS/I trip unit, which offers a choice between short-time and instantaneous protection, the Ekip LSI arrangement incorporates all three L, S and I protection functions. This provides additional flexibility for coordinating protection across multiple levels of an electrical distribution network, subject to the available settings and the overall system design.
The four-pole construction supports installations where three phase conductors and a neutral conductor must be switched together. This arrangement is particularly useful in compatible three-phase and neutral distribution systems. The neutral pole's protection characteristics and suitability must be verified for the specific circuit breaker configuration and installation requirements.
The ABB SACE Tmax XT2N160 platform combines compact moulded case construction with electronic protection. Its 120 mm nominal four-pole width provides a space-efficient footprint for compatible distribution boards and switchboards. When installing the EPX-XT2N-E2-0634, electrical designers should verify conductor ratings, prospective fault current, neutral arrangements, electronic trip settings and protective device coordination before commissioning.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | SACE Tmax XT |
| Circuit breaker frame | XT2 |
| Performance level | XT2N |
| Frame configuration | XT2N160 |
| ABB order code | 1SDX254828R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 63 A |
| Maximum frame rating | 160 A |
| Number of poles | 4P (four pole) |
| Short-circuit breaking capacity | 36 kA |
| Trip unit | Ekip LSI |
| Trip technology | Electronic |
| Overload protection | L – long-time protection |
| Short-time protection | S – short-time delayed short-circuit protection |
| Instantaneous protection | I – instantaneous short-circuit protection |
| Protection configuration | LSI – long-time, short-time and instantaneous functions |
| Rated operational voltage | Up to 690 V AC |
| Rated frequency | 50/60 Hz |
| Nominal width | 120 mm |
| Applicable standard | IEC 60947-2 |
| Installation type | Electrical distribution board / switchboard mounting |
| Compatible system | ABB Protecta Power |
| Product category | Protecta Power Devices |
The ABB EPX-XT2N-E2-0634 is a 63 A four-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using an Ekip LSI electronic trip unit.
The EPX-XT2N-E2-0634 has a 63 A rated current and uses the ABB SACE Tmax XT2N160 platform, which has a maximum frame rating of 160 A. The frame rating does not change the specified 63 A rating of this device.
The EPX-XT2N-E2-0634 is specified with a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.
LSI identifies an electronic protection arrangement incorporating L (long-time overload protection), S (short-time delayed short-circuit protection) and I (instantaneous short-circuit protection). These functions provide configurable protection characteristics for low-voltage electrical distribution systems.
Ekip LSI incorporates long-time, short-time delayed and instantaneous protection functions together. Ekip LS/I provides long-time overload protection with a choice between short-time delayed or instantaneous short-circuit protection. The LSI arrangement offers additional flexibility for protective device coordination.
Both circuit breakers use the ABB SACE Tmax XT2N160 four-pole platform and have a rated current of 63 A with 36 kA breaking capacity. The EPX-XT2N-E1-0634 uses Ekip LS/I electronic protection, while the EPX-XT2N-E2-0634 uses Ekip LSI electronic protection, incorporating separate long-time, short-time and instantaneous functions.
The ABB EPX-XT2N-E2-0634 uses the four-pole XT2 frame arrangement with a nominal width of 120 mm. Additional installation clearance may be required depending on the mounting arrangement, terminals and accessories.
Yes. The EPX-XT2N-E2-0634 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT2 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.
ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT2N-E2-0634 combines a 63 A four-pole XT2N160 circuit breaker with 36 kA breaking capacity and Ekip LSI electronic protection, delivering a compact and configurable solution for compatible ABB Protecta Power distribution assemblies.