ABB EPX-XT2N-E2-0254 (1SDX254827R1) is a 25 A four-pole SACE Tmax XT2N160 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip LSI electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection for three-phase outgoing circuits requiring four-pole switching.
£1,515.58
The ABB EPX-XT2N-E2-0254 is a high-performance 25 A four-pole moulded case circuit breaker (MCCB) designed to deliver dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices product group, this electronic circuit breaker combines a compact design with configurable protection technology for commercial, industrial and building services applications.
Built around the established ABB SACE Tmax XT2N160 circuit breaker platform, the EPX-XT2N-E2-0254 incorporates an ABB Ekip LSI electronic trip configuration. This provides three essential overcurrent protection functions: long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. Together, these functions support precise circuit protection and coordination within appropriately designed electrical distribution networks.
With a 25 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT2N-E2-0254 is suitable for three-phase outgoing circuits where coordinated switching of the phase conductors and neutral conductor is required. Its 120 mm nominal width supports efficient integration into compatible ABB Protecta Power distribution assemblies.
Identified by ABB order code 1SDX254827R1, this MCCB is a practical choice for electrical contractors, consulting engineers, panel builders and facilities managers seeking a 25 A, 4P, 36 kA electronic LSI circuit breaker with configurable protection characteristics and the engineering pedigree of the ABB SACE Tmax XT range.
The ABB EPX-XT2N-E2-0254 25 A electronic MCCB is designed to help maintain the safety and reliability of commercial and industrial low-voltage electrical installations. By automatically interrupting current under defined abnormal conditions, the circuit breaker helps protect cables, distribution equipment and connected electrical loads against the potentially damaging effects of overloads and short circuits.
Unlike conventional thermal-magnetic circuit breakers, which rely on thermal and magnetic mechanisms to initiate tripping, the EPX-XT2N-E2-0254 uses an electronic trip release to evaluate current conditions and operate according to its configured protection characteristics. This electronic approach provides greater flexibility for electrical engineers responsible for circuit protection design and coordination.
The ABB Ekip LSI electronic trip configuration incorporates three important protection functions. Long-time protection (L) responds to sustained overload conditions that could otherwise cause excessive heating of electrical conductors and connected equipment. Its operating characteristics are selected to suit the protected circuit and the capabilities of the fitted release.
Short-time protection (S) responds to short-circuit conditions with a defined delay characteristic. Where supported by the overall protection design, this can help an upstream protective device remain closed long enough for an appropriately selected downstream device to clear a fault. Achieving discrimination or selectivity requires verification using the relevant ABB coordination data and cannot be assumed solely from the presence of an LSI trip unit.
Instantaneous protection (I) provides rapid operation when fault current reaches the applicable instantaneous threshold. This function is particularly important in limiting the duration of severe short-circuit conditions. Together, the L, S and I functions provide a comprehensive overcurrent protection arrangement for suitably designed low-voltage electrical circuits.
The distinction between LSI and LS/I is significant when specifying electronic MCCBs. An LSI release incorporates long-time, short-time and instantaneous protection functions together. An LS/I release provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. The LSI arrangement offers additional flexibility where both delayed and instantaneous short-circuit protection characteristics are required.
The four-pole configuration of the ABB EPX-XT2N-E2-0254 enables coordinated switching of three phase conductors and a neutral conductor. This makes the breaker suitable for appropriately designed three-phase distribution circuits where neutral disconnection forms part of the installation requirements.
Four-pole circuit breakers are commonly considered for commercial distribution boards, building services panels and other installations where the electrical design calls for switching all live conductors. Whether neutral switching is required or permitted depends on the earthing arrangement, applicable electrical regulations and the intended operating conditions.
It is important to distinguish between neutral switching and neutral overcurrent protection. A four-pole MCCB provides a fourth switching pole, but this does not automatically confirm that the neutral conductor has the same overcurrent protection characteristics as the phase conductors. The specific neutral protection arrangement should be checked against the fitted ABB electronic release and associated technical documentation.
For installation planning, the ABB XT2 four-pole platform has a nominal width of 120 mm. This compact construction helps panel builders and electrical designers allocate space within compatible distribution boards while accommodating the four-pole switching arrangement.
The 25 A rating of the EPX-XT2N-E2-0254 identifies the rated current of the specified protective device. It should not be confused with the 160 A frame rating of the XT2N160 platform. The frame rating describes the circuit breaker platform, while the rated current and fitted electronic release determine the protective device selected for the circuit.
The specified 36 kA short-circuit breaking capacity is another essential selection parameter. The prospective short-circuit current at the point of installation must be assessed, and the circuit breaker's applicable breaking capacity must be confirmed for the operating voltage and installation conditions. A breaking-capacity figure should not be assumed to apply identically at every voltage.
Electrical designers should also assess conductor sizing, load characteristics, electronic trip settings, upstream and downstream protective devices, neutral conductor requirements and the available space within the distribution assembly. Where discrimination, cascading or back-up protection is required, the relevant ABB coordination documentation should be consulted.
For projects using the ABB Protecta Power distribution system, the EPX-XT2N-E2-0254 offers a clearly identified electronic MCCB option with a 25 A rating, four-pole switching and LSI protection. Appropriate mounting, terminals, connections and assembly compatibility should be verified before installation.
| Product group | Protecta Power Devices |
|---|---|
| Product range | SACE Tmax XT |
| Circuit breaker platform | XT2N160 |
| Model / SKU | EPX-XT2N-E2-0254 |
| ABB order code | 1SDX254827R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 25 A |
| Frame rating | 160 A |
| Short-circuit breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Trip unit designation | Ekip LSI |
| Trip technology | Electronic |
| Protection designation | LSI |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Delayed short-circuit protection |
| Instantaneous protection (I) | Instantaneous short-circuit protection |
| Protection arrangement | Long-time, short-time and instantaneous overcurrent protection |
| Electronic trip adjustment | Refer to the fitted ABB Ekip LSI release documentation |
| Neutral switching | Four-pole construction |
| Neutral overcurrent protection | Dependent on the fitted release and neutral pole arrangement |
| Applicable circuit breaker standard | IEC 60947-2 |
| Nominal device width | 120 mm |
| Installation type | Fixed installation within a compatible distribution assembly |
| Mounting compatibility | ABB Protecta Power, subject to appropriate mounting and connection arrangements |
| Electrical application | Three-phase low-voltage distribution with four-pole switching |
| Typical use | Outgoing feeder and sub-distribution circuit protection |
The ABB EPX-XT2N-E2-0254 is a 25 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an ABB Ekip LSI electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies. Its four-pole construction supports coordinated switching of three phase conductors and a neutral conductor.
The EPX-XT2N-E2-0254 has a 25 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It uses the ABB SACE Tmax XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.
LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to sustained overloads, short-time protection provides delayed short-circuit protection and instantaneous protection provides rapid operation under high fault-current conditions. These functions help engineers configure an appropriate circuit protection strategy.
A four-pole LSI MCCB combines coordinated switching of three phase conductors and a neutral conductor with electronic long-time, short-time and instantaneous protection functions. This makes it suitable for appropriately designed three-phase distribution systems where neutral switching and configurable overcurrent protection are required. The neutral overcurrent protection arrangement must be verified separately.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT2 four-pole platform has a nominal width of 120 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design, ABB instructions and applicable electrical regulations.
ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT2N-E2-0254 combines a 25 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip LSI electronic protection in a compact device intended for compatible ABB Protecta Power distribution systems.